GenieACS

io.github.GeiserXPublished by GitHub account GeiserXv0.4.2Updated Nov 19, 2026

MCP server bridging GenieACS TR-069 ACS instances to LLMs for CPE device management

Overview

AI-generated overview

Bridges a GenieACS TR-069 ACS so an assistant can find, inspect and manage CPE routers and ONTs from chat.

What you can do
  • Search devices by tag, model, firmware, last inform or any TR-069 parameter, and list them
  • Read cached parameter values, full device trees, tasks, faults, presets, provisions and files
  • Refresh parameters, set parameter values, reboot devices, push firmware and send connection requests
  • Tag devices, create or delete presets and provisions, and delete or retry queued tasks
When to use it
Useful when you run GenieACS for a fleet of routers or ONTs and want to ask questions in plain words, such as which devices stopped informing or what firmware a serial runs, and then act on the results without opening the ACS UI.
Requirements
A reachable GenieACS NBI endpoint, set via ACS_URL, plus ACS_USER and ACS_PASS for basic auth. Runs locally over stdio as an npm package, Docker image or Go binary; Node.js is needed for the npx route. Optional variables tune timeouts, response size, device limits and which tools are served.
Before you install
Ten of the twelve tools change devices or the ACS: rebooting, setting parameters, pushing firmware, tagging, and editing presets or provisions that apply fleet-wide. A wrong parameter or firmware image can cut a device off or brick it. Credentials are passed as ACS_USER and ACS_PASS. Use GENIEACS_READ_ONLY or GENIEACS_TOOLS to limit exposure, and confirm broad changes first.

Installation

In SourceWeft

  1. Open GenieACS in the dashboard and add it to a workspace.
  2. Enable the server for the chats that should use its tools.

Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.

Other MCP clients

Follow the launch instructions in the repository.

README

[genieacs-mcp]

[npm] [CI] [Coverage] [Go Reference] [License] [Docker Pulls] [GitHub Stars]

genieacs-mcp is an MCP server for GenieACS, the open-source TR-069 ACS that manages routers, ONTs and other CPE devices. Add it to Claude Desktop, Cursor or any other MCP client and ask in plain words: which devices stopped informing last night, what firmware serial 000003 runs, reboot the ones tagged pilot. The assistant reads and acts through your GenieACS NBI with 7 resources and 12 tools; one Go binary, no database of its own.

[MCP Inspector connected to genieacs-mcp: the search_devices tool run with the query _tags residential, and the result listing simulated Huawei BM632w devices with their ids, manufacturer, last inform and tags]

Features

  • Find devices the way you would ask a colleague: by tag, model, firmware, last inform, or any TR-069 parameter (search_devices takes a MongoDB-style filter).
  • Read a device's full parameter tree, its tasks and its faults, plus the presets, provisions and files on the ACS, as resources (genieacs://device/{id}, genieacs://devices/list, ...).
  • Reboot a device, push firmware to it, refresh or set a parameter, or wake it with a connection request, from a chat.
  • Tag devices, create or delete presets and provisions, and delete or retry tasks, so the assistant can fix what it finds.
  • Every tool description says what it does, its limits and an example, so clients pick the right one without a prompt from you.
  • Read versus act: search_devices, get_parameter and the seven resources only read; the other ten tools queue a task on a device or change the ACS, and each tool's hints say which, so your client can ask before the ones that act.
  • Read-only mode: GENIEACS_READ_ONLY=true serves only the two reading tools and the resources; GENIEACS_TOOLS=search_devices,reboot_device serves only the tools you name.
  • Speaks MCP 2026-07-28 and every earlier version back to 2024-11-05, so new and old clients both connect, over stdio or stateless HTTP.
  • Safe on a laptop: the HTTP transport listens on loopback only unless you set an address and a bearer token, and checks Host and Origin against DNS rebinding.
  • One static Go binary for Linux, macOS and Windows on amd64 and arm64, also as an npm package (npx genieacs-mcp) and a Docker image.

Quick start

You need a GenieACS whose NBI (port 7557) this machine can reach; without one, the family's demo stack gives you an ACS with a simulated router in about a minute:

sh
curl -fsSLO https://raw.githubusercontent.com/GeiserX/genieacs-container/main/docker-compose.ymldocker compose --profile testing up -d      # GenieACS + MongoDB + one simulated CPE, NBI on localhost:7557

Then add the server to a client that reads an mcpServers block (Claude Desktop, Cursor, Claude Code; in VS Code the .vscode/mcp.json key is servers):

json
{  "mcpServers": {    "genieacs": {      "command": "npx",      "args": ["-y", "genieacs-mcp"],      "env": { "ACS_URL": "http://localhost:7557" }    }  }}

The same server in other clients:

sh
# Claude Codeclaude mcp add --transport stdio --env ACS_URL=http://localhost:7557 genieacs -- npx -y genieacs-mcp
# Docker, over stdio (any client that starts a command)docker run -i --rm -e ACS_URL=http://host.docker.internal:7557 drumsergio/genieacs-mcp:v0.4.2
jsonc
// VS Code, .vscode/mcp.json{ "servers": { "genieacs": { "type": "stdio", "command": "npx", "args": ["-y", "genieacs-mcp"], "env": { "ACS_URL": "http://localhost:7557" } } } }
toml
# Codex, ~/.codex/config.toml[mcp_servers.genieacs]command = "npx"args = ["-y", "genieacs-mcp"]env = { ACS_URL = "http://localhost:7557" }

It worked when you ask "which devices does the ACS know about?" and the assistant answers with device ids such as 202BC1-BM632w-000000 (the demo stack) or your own. Docker, the HTTP transport and a local build are in Getting started.

Documentation

The full documentation is at geiserx.github.io/genieacs-mcp.

  • Getting started: npm, Docker Compose, local build, and what the first exchange looks like
  • Configuration: every environment variable, the HTTP transport's security model, client config for stdio and HTTP
  • Usage: the 7 resources and 12 tools with their arguments, which ones act on devices, example prompts
  • Development: tests, trying the server with MCP Inspector, contributing
  • Related projects: the GenieACS family, other MCP servers, where this server is listed

Related projects

Listed in the official MCP Registry as io.github.GeiserX/genieacs-mcp. Part of the GenieACS family: genieacs-container (the ACS itself, Docker and Helm, with this server as a compose profile), genieacs-sim-container, genieacs-ansible, genieacs-ha, genieacs-services, and n8n-nodes-genieacs (archived).

License

GPL-3.0-or-later

Source: README.md at commit c2562c6

Tools

12

connection_request

Wake device (connection request)

Send a TR-069 connection request so a CPE device contacts GenieACS now instead of at its next periodic inform. Use it to run tasks that are already queued, or to apply a preset change without waiting. It queues nothing itself. Succeeds when the device answered; fails with ACS error 504 when the device is unreachable (offline, or behind NAT without STUN). Example: connection_request(device_id="202BC1-BM632w-000001").

Parametersdevice_idrequired

delete_task

Delete queued task

Remove a task from the GenieACS queue before the device runs it, for example a firmware download or reboot queued by mistake, or a faulted task you do not want retried. GenieACS already deletes a task once the device has run it, so every task you can see in genieacs://tasks/{device_id} is either waiting or faulted. Fails with ACS error 503 while the device is in a session with GenieACS; try again a few seconds later. Use retry_task instead to run a faulted task again. Example: delete_task(task_id="67abc123def4560012345678").

Parameterstask_idrequired

download_firmware

Push firmware or file to device

Tell a CPE device to download and apply a file stored on GenieACS: a firmware image, a configuration file or another file the device accepts. A wrong image can leave a device unusable, so check the file's metadata (genieacs://file/{name}: OUI, product class, version) against the device first. GenieACS queues a download task and sends a connection request at once; the transfer itself can take minutes after the tool returns. Check genieacs://tasks/{device_id} and genieacs://faults/{device_id} afterwards. Example: download_firmware(device_id="202BC1-BM632w-000001", file_id="firmware-v2.0.bin").

Parametersfile_idrequiredfilenamedevice_idrequired

get_parameter

Read cached device parameters

Read TR-069 parameter values GenieACS has cached for a device, without contacting the device: firmware version, serial number, uptime, WiFi SSID, IP addresses and so on. Values are what the device reported at its last inform or refresh, with a timestamp each; call refresh_parameter first when you need a value from the device now. Give one path or a comma-separated list; an object path such as "Device.WiFi" returns every cached leaf under it. Returns found=false for an unknown device id, and lists paths with no cached value under missing.

Parametersdevice_idrequiredparameter_pathrequired

manage_preset

Create, replace or delete preset

Create, replace or delete a GenieACS preset. A preset is a fleet-wide rule: at their next inform, every device matching its precondition gets its configurations applied, so a broad precondition (or an empty one) reconfigures the whole fleet. Confirm the precondition and the devices it matches (search_devices with the same filter) before a put. action="put" creates or overwrites the preset with body; action="delete" removes it. body is a JSON object: weight (integer, higher wins), precondition (a MongoDB-style filter as a JSON string, e.g. "{\"_tags\":\"office\"}"), and configurations (an array of {type: "value" | "provision" | "add_object" | "delete_object", ...}). Example body: {"weight":0,"precondition":"{\"_tags\":\"pilot\"}","configurations":[{"type":"provision","name":"myScript"}]}. Read genieacs://presets/list first.

Parametersbodynamerequiredactionrequired

manage_provision

Create, replace or delete provision script

Create, replace or delete a GenieACS provision script. A provision is JavaScript that GenieACS runs during the inform session of every device a preset applies it to, so replacing one changes how those devices are configured. Scripts use the GenieACS sandbox API (declare, commit, clear, ext, log); ext() calls extension scripts that run on the ACS host with full privileges, so treat a provision as code running on your ACS. action="put" uploads or overwrites the script (raw JavaScript, not JSON; GenieACS answers 400 on a syntax error); action="delete" removes it. Presets reference provisions by name. Read genieacs://provisions/list first. Example script: log("Device " + DeviceID.ID + " informed");

Parametersnamerequiredactionrequiredscript

reboot_device

Reboot device

Reboot a CPE device through GenieACS. Use it when a device needs a restart, for example after a configuration change or to recover an unresponsive device. The device drops its service while it restarts. GenieACS queues the task and sends a connection request at once: status "done" means the device ran it in that session, "queued" means it runs at the device's next inform. A reboot does not confirm the device came back; read Device.DeviceInfo.UpTime (or InternetGatewayDevice.DeviceInfo.UpTime) with refresh_parameter afterwards. Example: reboot_device(device_id="202BC1-BM632w-000001").

Parametersdevice_idrequired

refresh_parameter

Refresh parameter from device

Ask a CPE device for the current value of a TR-069 parameter, or of every parameter under an object path, and store it in GenieACS. Use it when get_parameter's cached value may be stale. It changes nothing on the device. GenieACS queues a getParameterValues task and sends a connection request at once: status "done" means the fresh value is already stored, so read it with get_parameter; "queued" means it arrives at the device's next inform. Example: refresh_parameter(device_id="202BC1-BM632w-000001", parameter="Device.DeviceInfo.SoftwareVersion").

Parametersdevice_idrequiredparameterrequired

retry_task

Retry faulted task

Run a faulted task again: GenieACS clears the task's fault, and the device runs the task at its next session. Read genieacs://faults/{device_id} first to see why it failed; retrying a task whose cause is unchanged faults again. A task that has not faulted is left as it is. Example: retry_task(task_id="67abc123def4560012345678").

Parameterstask_idrequired

search_devices

Search devices

Find CPE devices in GenieACS with a MongoDB-style filter: by tag, manufacturer, model, firmware version, last inform time or any TR-069 parameter. It only reads. Examples: {"_tags":"office"}; {"InternetGatewayDevice.DeviceInfo.Manufacturer":"Huawei"} (GenieACS adds ._value to parameter paths); {"_lastInform":{"$lt":"2026-01-01T00:00:00Z"}} for devices silent since that date; {"_id":{"$regex":"^202BC1-"}}. Query operators such as $eq, $ne, $gt, $lt, $in, $nin, $exists, $regex, $and and $or work; $where, $function, $accumulator and $expr are refused, and a $regex pattern may be at most 256 characters. By default each device comes back as a summary (id, last inform, tags, manufacturer, product class, serial); ask for other fields with projection. Results come in pages of limit (default 50, at most 200); page with skip.

Parametersskipsortlimitqueryrequiredprojection

set_parameter

Set device parameters

Write one or more TR-069 parameter values on a CPE device, overwriting the current values: WiFi SSID or key, periodic inform interval, management server URL, or any writable parameter. A wrong value can cut the device off (a wrong WAN or ACS URL setting, for example). parameter_values is a JSON array of [path, value] or [path, value, xsdType] tuples; xsd types include xsd:string, xsd:boolean, xsd:unsignedInt, xsd:int and xsd:dateTime, and GenieACS infers the type when it is omitted. Example: [["InternetGatewayDevice.LANDevice.1.WLANConfiguration.1.SSID","Lab-2","xsd:string"]]. GenieACS queues the task and sends a connection request at once: status "done" means the device applied it, "queued" means it runs at the next inform. A read-only or unknown parameter makes the device fault the task; see genieacs://faults/{device_id}. Read the current value with get_parameter first.

Parametersdevice_idrequiredparameter_valuesrequired

tag_device

Add or remove device tag

Add a tag to a CPE device or remove one. Tags group devices: presets match on them (precondition {"_tags":"office"}) and search_devices finds by them. Adding or removing a tag can therefore make a preset apply to the device, or stop applying, at its next inform. Tags are case-sensitive. Use letters, digits, "-" and "_": GenieACS rejects a tag with other characters (a "." for example) with a 404. Fails with ACS error 404 when the device id does not exist. Example: tag_device(device_id="202BC1-BM632w-000001", tag="office", action="add").

Parameterstagrequiredactionrequireddevice_idrequired

Version history

7
  1. v0.4.2LatestNov 17, 2026
  2. v0.4.1Oct 29, 2026
  3. v0.3.7Oct 21, 2026
  4. v0.3.6Oct 14, 2026
  5. v0.3.5Oct 13, 2026
  6. v0.3.4Oct 5, 2026
  7. v0.0.12Sep 16, 2026

Score

90% of the applicable checks met

How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.

  • Reached in the last 30 days25 pts
  • Auth declared10 pts

    Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.

  • Tools listedRequired15 pts
  • DescriptionRequired15 pts
  • Logo10 pts
  • Documentation15 pts
  • License10 pts