ASTM LIS Analyzer Receiver

io.github.K-Dense-AIPublished by GitHub account K-Dense-AIv0.1.3Updated Oct 24, 2026

MCP server that receives results from clinical/lab analyzers over ASTM E1381/E1394 (CLSI LIS1/LIS2).

VerifiedSTDIODesktop onlyLocation & LifestyleData & Analytics

Overview

AI-generated overview

Receive-only MCP server that collects ASTM E1381/E1394 results from clinical lab analyzers and lets an assistant query them by sample, patient, test or time.

What you can do
Query received results filtered by sample ID, patient ID, test code, time received or abnormal flag, and open one result's full decoded fields, comments and raw records. List recent ASTM messages and inspect the analyzer link state, message counts and link-layer error counters. Check connection identity, address, read-only mode and active limits, and review the raw command log for debugging. Reconnect the link after a power cycle or cable change, and clear stored results between runs.
When to use it
For laboratory operations and research work where an analyzer uploads results over an ASTM host interface and you want an assistant to look up, filter or summarize what arrived. Not for reporting, releasing or interpreting patient results, diagnosis or any clinical decision-making.
Requirements
Runs locally as a Python package (uvx labmcp-astm-lis) over stdio; desktop only. Needs a link to the analyzer: a serial device path, or a TCP address or listen port, set via LABMCP_ADDRESS or command-line options. The analyzer must have ASTM E1381 framing and automatic result upload enabled, with host query and order modes turned off. LABMCP_SIMULATE=1 runs a built-in simulator without hardware.
Before you install
Explicitly not a medical device or validated LIS; results pass through an AI agent that can misread them, so rely on the validated LIS and release process. Patient name, birth date, address and phone are redacted by default, but patient IDs, sex, physician and free-text comments are not, so follow institutional privacy rules. Listen mode has no TLS; restrict senders with allow_from and keep the port on the lab network. clear_results deletes stored messages; LABMCP_READ_ONLY=1 hides it. Only the

Installation

In SourceWeft

  1. Open ASTM LIS Analyzer Receiver in the dashboard and add it to a workspace.
  2. Enable the server for the chats that should use its tools.

Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.

Other MCP clients

Follow the launch instructions in the repository.

README

ASTM LIS Analyzer Receiver — MCP Server

Let an AI agent collect and query results from clinical and laboratory analyzers (hematology, clinical chemistry, immunoassay, urinalysis, coagulation) that upload results over the standard ASTM E1381 / E1394 host interface (CLSI LIS1-A / LIS2-A2). The server acts as a small, receive-only LIS endpoint: it acknowledges the analyzer's frames, validates checksums, reassembles messages and lets the agent look results up by sample, patient, test or time.

[!WARNING] Research and lab-operations use only. This is not a medical device and not a validated laboratory information system. It must not be used to report, release or interpret patient results, for diagnosis, or for any clinical decision-making. Results pass through an AI agent that can misread them; always rely on your laboratory's validated LIS/middleware and release process. Patient data is personal health information: patient name, birth date, address and phone are redacted by default; follow your institution's privacy rules before changing that.

Packagelabmcp-astm-lis
InstrumentsAnalyzers whose host-interface manual specifies ASTM E1381/E1394 (CLSI LIS1-A/LIS2-A2) result upload, e.g. models from Sysmex, Roche (cobas), Abbott, Beckman Coulter, Mindray and others. Check your model's host-interface manual.
InterfacesRS-232 (serial://), TCP/IP with the analyzer as server (tcp://analyzer:port), TCP/IP with the analyzer as client (--option listen_port=5000)
ProtocolASTM E1381 low-level protocol (ENQ/ACK/NAK/EOT, framed text with modulo-8 frame numbers and checksums) + ASTM E1394 records H, P, O, R, C, Q, L. Implemented from the publicly available Beckman Coulter UniCel DxI / Access 2 LIS Vendor Information, C03112-AF (chapters 2–4); the ASTM/CLSI standards themselves are purchase-only. Receive-only.
Status🧪 simulated: tested against a wire-level analyzer simulator and loopback TCP, not yet verified on an analyzer. Report a hardware test

Try it without hardware

bash
uvx labmcp-astm-lis --simulate --check

The simulated analyzer uploads two messages right after start: a CBC with 5-part differential (with H/L flags and suspect-flag comments, one record long enough to need two frames, and one frame corrupted on the line that is NAKed and retransmitted) and a chemistry panel (high glucose and potassium with a hemolysis comment). All patient data in it is fictitious.

Connect your analyzer

On the analyzer, open the host / LIS / "online" communication settings:

  1. Protocol: ASTM (may be called ASTM E1381/E1394, LIS1-A/LIS2-A2, CLSI or "ASTM host"). Keep the ASTM low-level protocol (ENQ/STX framing) enabled, also over TCP/IP.
  2. Results: enable automatic result upload.
  3. Queries and orders: this server does not answer host queries or download orders. Turn off "host query" / "order request" / bidirectional mode, otherwise the analyzer waits for (and times out on) an answer before running samples.
  4. Link: pick one of
    • RS-232: note the baud rate (commonly 9600), 8 data bits, no parity, 1 stop bit (fixed by E1381), and use a null-modem cable.
      bash
      uvx labmcp-astm-lis --address /dev/ttyUSB0 --check                        # Linuxuvx labmcp-astm-lis --address serial://COM3?baudrate=19200 --check        # Windows, non-default baud
    • TCP, analyzer is the server (it listens on a port): the LIS connects to it.
      bash
      uvx labmcp-astm-lis --address tcp://192.168.1.80:5000 --check
    • TCP, analyzer is the client (you enter the host IP/port on the analyzer): this server listens. Allow the port through the computer's firewall and restrict senders with allow_from.
      bash
      uvx labmcp-astm-lis --option listen_port=5000 --option allow_from=192.168.1.80 --check
  5. Optional: keep a local record of every message with --option store_path=~/lis/results.jsonl (the newest max_messages are reloaded when the server restarts; if the file cannot be written, messages are still kept in memory and get_connection_status reports store_write_errors).

The receiver starts as soon as the MCP server starts, so uploads are acknowledged even before the agent calls a tool. Received results stay in memory across reconnect (only clear_results or a server restart without store_path removes them), because the analyzer never re-sends a result it has been sent an ACK for.

Add to your MCP client

Claude Code

bash
claude mcp add analyzer -- uvx labmcp-astm-lis --option listen_port=5000 --option store_path=~/lis/results.jsonl

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

json
{  "mcpServers": {    "analyzer": {      "command": "uvx",      "args": ["labmcp-astm-lis", "--address", "/dev/ttyUSB0"]    }  }}

Add --read-only to hide clear_results. For other clients, generate the snippet with uvx labmcp config astm-lis --address /dev/ttyUSB0 --client vscode (also cursor, codex, claude-code).

Tools

ToolKindDescription
clear_results🎛 controlDelete all received messages and results from this server's memory (e.g. between runs).
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_connection_status👁 readReport the analyzer link state, the messages and results received, and link-layer error counters.
get_result_detail👁 readShow every decoded field of one result, with its comments, order and patient context, raw records and message header.
get_results👁 readReturn received results, filtered by sample ID, patient ID, test code, time received or abnormal flag (newest last).
list_received_messages👁 readList the most recent ASTM messages received (newest last).
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).

get_connection_info, get_command_log and reconnect are built into every LabMCP server.

Safety limits

This server is receive-only and never commands the analyzer (it only answers ACK/NAK), so it has no physical safety limits. Privacy settings:

OptionDefaultMeaning
redact_patient_infotrueMasks P-record fields 6 (patient name), 7 (mother's maiden name), 8 (birth date), 11 (address) and 13 (telephone) as REDACTED before anything is stored, logged, written to store_path or returned by a tool
allow_from(any)In listen mode, only accept connections from these IP addresses (;- or space-separated)
max_messages5000Messages kept in memory; oldest are dropped first

Patient IDs, sex, attending physician and free-text comment records are not redacted (IDs are needed to filter results). If your analyzers put identifying text in comments, treat the output accordingly.

Example prompts

  • "Have any results come in from the hematology analyzer in the last hour? List the samples."
  • "Show me all flagged results for sample S26-000123, with units, reference ranges and the analyzer's comments."
  • "Export today's potassium results as a table of sample ID, value and flag."
  • "Is the analyzer link healthy? How many frames were NAKed today and why?"
  • "Compare the glucose results of samples S26-000124 and S26-000131."
  • "Clear the stored results before we start the next validation run."

Notes

  • Receive-only. No order download, no host-query responses and no result acknowledgements beyond the link-level ACK. Query (Q) messages from the analyzer are stored and reported (kind: "query") but not answered. Order download is planned future work.
  • Link layer (E1381). Every frame is checked: checksum (modulo-256 sum from the frame number to ETX/ETB, as two hex digits), frame number (first frame 1, then modulo 8; a repeat of the last accepted number is treated as a retransmission and ACKed without duplicating data) and framing. Defective frames get NAK and the analyzer retransmits them. Frames outside an ENQ … EOT session are ignored and counted in bytes_ignored, which usually means the analyzer is not using the ASTM low-level protocol (raw E1394 without framing is not supported). A session that goes silent for 30 s, or restarts with ENQ, has its incomplete message discarded, as E1381 requires; a message that ends with EOT but no terminator (L) record is kept and flagged complete: false.
  • Tolerances. Frames with more than 240 text characters and end frames that pack several records are accepted (and counted); a frame whose CR LF never arrives is NAKed after 10 s. Text is decoded as Latin-1 by default (--option encoding=...; an unknown encoding name is refused at start-up).
  • Records (E1394). Delimiters are taken from each header record (H|\^& by default). Escape sequences &F& &S& &R& &E& and the vendor form &|& are decoded; other escapes are kept verbatim. The test code is the first non-empty "local code" component of the Universal Test ID (^^^TSH, ^^^^WBC), falling back to the first component. The sample ID is the order's Specimen ID, or the first non-empty component of the Instrument Specimen ID. Values are returned exactly as sent ("<0.1", ">500", "Cancelled"); numeric_value is only set for plain numbers.
  • Flags and statuses are passed through as sent. Meanings are only attached for the abnormal flags defined by LIS2-A2 / E1394 (N L H LL HH < > A U D B W) and the result statuses documented in the vendor specification used (F X); anything else is analyzer-specific, so check your analyzer's host-interface manual.
  • Timestamps inside records (test started/completed, header time) are the analyzer's local time; received_at is when this server stored the message (UTC).
  • Listen mode serves one analyzer per port: a new connection replaces the previous one (analyzers often reconnect after a reboot without closing the old socket). Run one server entry (or port) per analyzer. There is no TLS; keep the port on the lab network and use allow_from.
  • Only tested against the simulator and loopback TCP. Differences between vendors' ASTM dialects are common; please report what works (or doesn't) with your analyzer.

Hardware verification

ModelFirmwareInterfaceVerified byDate
none yet: be the first

Source: servers/health/astm-lis-analyzer/README.md at commit 46545ea

Tools

0
SourceWeft has not started this package in its sandbox yet, so its tools are not known.

Version history

2
  1. v0.1.3LatestSep 27, 2026
  2. v0.1.1Sep 26, 2026

Score

50% of the applicable checks met

How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.

  • Reached in the last 30 days25 pts

    Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.

  • Auth declared10 pts

    Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.

  • Tools listed15 pts

    Answer tools/list without a credential, or ship a package that starts in a sandbox without one.

  • DescriptionRequired15 pts
  • Logo10 pts
  • Documentation15 pts
  • License10 pts