Atlas Scientific EZO Sensors
io.github.K-Dense-AIPublished by GitHub account K-Dense-AIv0.1.2Updated Oct 24, 2026
MCP server for Atlas Scientific EZO sensor circuits (pH, ORP, DO, EC, RTD, HUM, CO2, PRS) over UART.
The publisher's own server: Red Atlas Api
Overview
Local MCP server that lets an assistant read, calibrate and log Atlas Scientific EZO sensor circuits (pH, ORP, DO, EC, RTD, humidity, CO2, pressure) over UART.
- What you can do
- Read sensor values and circuit info: single readings with units, circuit type, firmware, calibration state and settings, plus connection details and a raw command log. Log series of readings with mean, standard deviation, min, max and drift, optionally saved to a new CSV file. Calibrate probes: store calibration points, check calibration status and slope, and clear stored calibration. Adjust settings: temperature compensation, DO salinity and pressure compensation, EC probe constant and the status LED. Reconnect the instrument after a power cycle or cable change.
- When to use it
- Useful when an assistant should monitor or calibrate Atlas Scientific EZO probes in bioreactors, cell culture, fermentation, hydroponics, aquaculture or environmental monitoring, or when you want readings logged and summarised without writing serial commands yourself.
- Requirements
- Runs locally as a Python package (uvx labmcp-atlas-ezo) over stdio, desktop only. Needs an EZO circuit in UART mode connected via USB-serial adapter or serial-to-Ethernet bridge, with the address given in LABMCP_ADDRESS or the address option. One server per circuit. A built-in simulator (LABMCP_SIMULATE) allows testing without hardware.
Installation
In SourceWeft
- Open Atlas Scientific EZO Sensors in the dashboard and add it to a workspace.
- Enable the server for the chats that should use its tools.
Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.
Other MCP clients
Follow the launch instructions in the repository.
README
Atlas Scientific EZO Sensors — MCP Server
Let an AI agent read, calibrate and log Atlas Scientific EZO™ sensor circuits (pH, ORP, dissolved oxygen, conductivity, RTD temperature, humidity, CO2 and pressure) over their documented UART command set. Useful for bioreactors, cell-culture media, fermentation, hydroponics, aquaculture and environmental monitoring.
Try it without hardware
Connect your instrument
- Circuit setup: the circuit must be in UART mode (LED green/cyan; blue means I2C mode, see "Change to UART mode" in the datasheet). Factory settings are 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control, CR line endings. Cross TX/RX between the circuit and the adapter, and use an electrically isolated carrier board when the probe sits in the same liquid as other probes or pumps.
- Find the port:
uvx labmcp ports - Test the connection:
On connect the server sends
C,0(continuous readings off, so replies are not interleaved with readings) and*OK,1(response codes on, the factory default). The circuit keeps both settings across power cycles.
Add to your MCP client
Claude Code
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
Run one server per circuit. Add --read-only to allow readings but block calibration and settings changes. For other clients, generate the snippet with uvx labmcp config atlas-ezo --address /dev/ttyUSB0 --client vscode.
Tools
get_connection_info, get_command_log and reconnect are built into every LabMCP server.
Safety limits
Override at launch: --limit max_series_duration_s=3600 (3600 s is the most one log_series call can run; split longer logs into several calls). log_series writes its optional save_path only to a new .csv file (existing files are never overwritten). These circuits only measure, so there are no hazardous tools; the risk is a bad calibration, which is why calibrate validates point names and standard values per circuit type and clear_calibration is hidden in --read-only mode.
Example prompts
- "What sensor is connected, is it calibrated, and what's the pH slope?"
- "The pH probe is in pH 7.00 buffer. Log it every 2 s until it's stable to ±0.01, then calibrate the midpoint. Then walk me through pH 4 and pH 10."
- "The bioreactor is at 37 °C: set the temperature compensation and read the dissolved oxygen in mg/L and % saturation."
- "Log conductivity, TDS and salinity every 30 s for 10 minutes and tell me whether the nutrient solution is drifting."
- "Turn off the LED on the DO circuit, we're running a light-sensitive culture."
Notes
- Units per circuit: pH; ORP in mV; DO in mg/L and (if enabled with
O,%,1) % saturation; EC in µS/cm plus TDS (ppm), salinity (PSU) and specific gravity when enabled; RTD in its configured scale (°C/K/°F); HUM in %RH plus air temperature and dew point (°C) when enabled; CO2 in ppm (+ internal temperature); PRS in its configured unit (psi, atm, bar, kPa, inH2O, cmH2O). Which outputs are enabled is read from the circuit (O,?,S,?,U,?) rather than assumed. - Output order of multi-value readings follows the datasheets (EC: EC,TDS,S,SG). The DO order (mg/L then % saturation) is not spelled out in the DO datasheet; it was cross-checked against the open-source EnviroDIY ModularSensors and feastorg
ezo-driverlibraries. Please report if your circuit differs. - Temperature compensation (
T,n, pH/EC/DO only) and DO salinity/pressure compensation are not retained when the circuit loses power; set them again after a power cycle. Readings report the compensation temperature in use. - Calibration rules enforced: pH midpoint must be calibrated before low/high (a new
miderases low/high, as the datasheet warns), with mid 6-8, low 0-6.5 and high 7.5-14; ORP ±1020 mV; EC 0.07-500,000 µS/cm (dodryfirst); CO2 high point 3000-5000 ppm; RTD -126 to 1254 °C. The server cannot see which standard the probe is actually in: the agent must confirm that with you. - An RTD reading of -1023 means no probe is connected; the reading includes a warning.
- DO queries such as
P,?answer?,P,90.25(note the extra comma) per the datasheet; the driver accepts both forms. The DO salinity reply contains a micro sign, so the port is read as Latin-1. - Not exposed as tools (verified but not useful or too risky for an agent):
Factory(erases calibration),Sleep,Find,Baud,I2C,Plock, calibrationExport/Import, the RTD data logger, and the HUM/CO2/PRS alarm pins. EZO pumps (EZO-PMP) and other actuator circuits are refused on connect.
Hardware verification
Source: servers/biology/atlas-ezo-sensors/README.md at commit 46545ea
Tools
0Version history
2- v0.1.2LatestSep 27, 2026
- v0.1.0Sep 26, 2026
Score
50% of the applicable checks met
How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.
- Reached in the last 30 days25 pts
Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.
- Auth declared10 pts
Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.
- Tools listed15 pts
Answer tools/list without a credential, or ship a package that starts in a sandbox without one.
- DescriptionRequired15 pts
- Logo10 pts
- Documentation15 pts
- License10 pts
Other Atlas integrations
Red Atlas Api
red.atlasOfficial publisher
Remote MCP server giving an assistant access to Puerto Rico and Colombia real estate data: listings, sales, parcels, permits, analytics and AVM reports.

MITRE ATLAS MCP Server
Published by GitHub account imouiche
Threat-models AI and agentic systems against MITRE ATLAS, mapping your architecture's surfaces to applicable techniques, mitigations and real incidents.

RxAtlas
Published by GitHub account vanja-ivancevic
Remote MCP server for looking up US drug products at FDA product-NDC grain, with source-linked provenance and cross-source identifiers.

Barzel FinOps Atlas
Published by GitHub account Realbizdigital
Remote MCP server for AI agent cost control: cost per outcome, budgets, spend limits, anomaly detection and audit evidence.

AI Obligations Atlas
Published by GitHub account Triodian
Searches a sourced atlas of AI governance obligations for Australia, Singapore and international standards, with tiers, dates and provenance.