Bench DC Power Supply

io.github.K-Dense-AIPublished by GitHub account K-Dense-AIv0.1.3Updated Oct 24, 2026

MCP server for programmable DC bench power supplies from Rigol, Siglent and Aim-TTi.

VerifiedSTDIODesktop onlyDeveloper ToolsSecurity & Monitoring

Overview

AI-generated overview

MCP server that lets an assistant control Rigol, Siglent and Aim-TTi programmable DC bench power supplies over SCPI, setting voltages, current limits and output

What you can do
Read instrument state: connection info, per-channel setpoints, measured voltage/current/power, CV/CC mode, protection levels and trip state, error queue, and a raw command log for debugging or recording what was done. Set channel voltage and current-limit setpoints, checked against safety limits and the model's range. Switch individual outputs on or off, or switch every output off as an emergency stop. Configure over-voltage and over-current protection and clear protection trips after fixing the cause. Reconnect to an instrument after a power cycle or cable change.
When to use it
Useful when an assistant should drive a real bench supply for test and measurement work: setting rails, ramping voltages and reading back current, checking CV/CC behaviour, or shutting outputs down quickly. A built-in simulator lets you try it without hardware.
Requirements
Runs locally as a Python package (labmcp-bench-psu, launched with uvx). Needs a supported instrument reachable over USB-TMC, LAN (VXI-11 or raw socket), RS-232 or GPIB, with its address given via LABMCP_ADDRESS or the address option; PyVISA is included, and NI-VISA or Keysight IO Libraries can be used instead. No authentication is declared.
Before you install
It energises real loads: output_on applies the present setpoints to whatever is connected, and set_voltage changes the load voltage immediately if the output is on. Safety limits (max_voltage_v, max_current_a) default to 30 V and 3 A and should be set for your load; LABMCP_READ_ONLY=1 hides setpoint changes and output_on but keeps output_off. The README states it is tested only against simulators, not yet on hardware, and some models lack protection or state readback.

Installation

In SourceWeft

  1. Open Bench DC Power Supply in the dashboard and add it to a workspace.
  2. Enable the server for the chats that should use its tools.

Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.

Other MCP clients

Follow the launch instructions in the repository.

README

Bench DC Power Supply — MCP Server

Let an AI agent set voltages and current limits, switch outputs on and off, watch constant-voltage / constant-current behaviour and configure over-voltage / over-current protection on programmable DC bench power supplies from Rigol, Siglent and Aim-TTi, using each vendor's documented remote command set. The dialect is detected from *IDN?.

Packagelabmcp-bench-psu
InstrumentsRigol DP832/DP832A, DP831, DP822, DP821, DP811, DP813, DP711, DP712, DP932A/U/E; Siglent SPD3303X/X-E, SPD1168X, SPD1305X; Aim-TTi CPX400D/DP, MX100T/TP, MX180T/TP, QL355/QL564 (P, T/TP), PL-P (PL068/155/303/601, PL303QMD/QMT)
InterfacesUSB (USB-TMC via VISA, or virtual COM on Aim-TTi), LAN (VISA/VXI-11 or raw socket), RS-232, GPIB via VISA
ProtocolSCPI (Rigol DP800 Programming Guide, DP700, DP900; Siglent SPD3303X Quick Start, SPD1000X User Manual) and Aim-TTi remote commands (CPX400D/DP manual, MX100T/TP manual, manuals index)
Status🧪 simulated: tested against wire-level simulators of each dialect driving a resistive load, not yet verified on hardware. Report a hardware test

Keysight / Agilent and Rohde & Schwarz supplies are intentionally not covered: both vendors publish official MCP servers. Use the Keysight MCP Server for Instrument Control or the MCP server included in Rohde & Schwarz RsInstrument. This server refuses to connect to them.

Try it without hardware

bash
uvx labmcp-bench-psu --simulate --check                                        # Rigol DP832uvx labmcp-bench-psu --simulate --option dialect=siglent --check               # Siglent SPD3303Xuvx labmcp-bench-psu --simulate --option dialect=tti --option sim_model=MX100TP --check

The simulated outputs drive resistive loads (CH1 10 Ω, CH2 100 Ω, CH3 open), so you can watch the CV → CC crossover and trip OVP/OCP.

Connect your instrument

  1. Instrument setup: enable the interface you use (Rigol: Utility → I/O Config; Siglent: System → Interface; Aim-TTi: LAN works out of the box, USB appears as a virtual COM port). Note the IP address or VISA resource string.
  2. Find the address: uvx labmcp ports (serial) or python -m pyvisa info / your VISA vendor's tool (USB/LAN).
  3. Test the connection:
    bash
    uvx labmcp-bench-psu --address "USB0::0x1AB1::0x0E11::DP8C123456789::INSTR" --check   # Rigol over USB-TMCuvx labmcp-bench-psu --address "TCPIP0::192.168.1.50::INSTR" --check                 # any LXI/VXI-11 supplyuvx labmcp-bench-psu --address tcp://192.168.1.51:5025 --check                       # Siglent raw socketuvx labmcp-bench-psu --address tcp://192.168.1.52:9221 --check                       # Aim-TTi raw socketuvx labmcp-bench-psu --address /dev/ttyACM0 --check                                  # Aim-TTi USB virtual COMuvx labmcp-bench-psu --address "serial://COM3?write_termination=CRLF" --check        # Rigol DP800 RS-232
    USB-TMC and VXI-11 addresses use PyVISA (installed with this package; add ?backend=@ivi to use NI-VISA / Keysight IO Libraries instead of pyvisa-py).

Add to your MCP client

Claude Code

bash
claude mcp add psu -- uvx labmcp-bench-psu --address "TCPIP0::192.168.1.50::INSTR" --limit max_voltage_v=12 --limit max_current_a=1

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

json
{  "mcpServers": {    "psu": {      "command": "uvx",      "args": ["labmcp-bench-psu", "--address", "TCPIP0::192.168.1.50::INSTR",               "--limit", "max_voltage_v=12", "--limit", "max_current_a=1"]    }  }}

Add --read-only to allow monitoring only: setpoint changes and output_on are hidden, while output_off and all_outputs_off stay available. For other clients, generate the snippet with uvx labmcp config bench-psu --address TCPIP0::192.168.1.50::INSTR --client vscode.

Tools

ToolKindDescription
all_outputs_off🛑 safetySwitch every output OFF (emergency stop for the whole supply). Each channel is switched individually and read back where the instrument supports it.
clear_protection_trip🎛 controlClear an OVP/OCP trip after fixing its cause. The output stays OFF; use output_on to re-energise. On Aim-TTi supplies this clears trips on all outputs.
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_errors👁 readRead (and clear) the instrument's error queue / error registers. Empty list = no errors.
get_outputs👁 readReport each channel: voltage and current-limit setpoints, measured voltage/current/power, output on/off, CV/CC mode, and OVP/OCP levels and trip state where the model supports them.
output_off🛑 safetySwitch a channel's output OFF. Safe to call at any time.
output_on⚠️ hazardSwitch a channel's output ON, energising the connected load at the present setpoints. The setpoints are read back first and the output is refused if they exceed the safety limits (e.g. after someone changed them on the front panel).
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_current_limit🎛 controlSet a channel's current limit (the constant-current setpoint). Refused above max_current_a (checked even with the output off) or above the channel's range.
set_protection🎛 controlSet over-voltage (OVP) and/or over-current (OCP) protection for a channel. When exceeded, the supply switches the output off. Rigol: levels + on/off; Aim-TTi CPX/QL/PL-P: levels (always armed), MX: levels + on/off; Siglent SPD1000X: levels only; SPD3303X: not available.
set_voltage🎛 controlSet a channel's voltage setpoint. Refused above max_voltage_v (checked even with the output off) or above the channel's range. If the output is on, the load sees the new voltage at once.

get_connection_info, get_command_log and reconnect are built into every LabMCP server.

Safety limits

LimitDefaultMeaning
max_voltage_v30 VLargest voltage setpoint (magnitude) on any channel. Checked when setting the voltage, even with the output off, and again before output_on
max_current_a3 ALargest current-limit setpoint on any channel, checked the same way

Override at launch, e.g. --limit max_voltage_v=12 --limit max_current_a=0.5. Setpoints are also checked against each model's settable range. output_on reads the setpoints back from the instrument first, so a value changed on the front panel cannot slip past the limits.

Example prompts

  • "Show me all channels of the power supply: setpoints, measured current and whether they're in CV or CC."
  • "Set CH1 to 12 V with a 200 mA current limit, set OVP at 13 V, then turn it on and tell me how much current the LED array draws."
  • "Ramp CH2 from 0 to 5 V in 0.5 V steps, reading the current at each step, and plot the I-V curve of the load."
  • "The heater is drawing more than expected: turn every output off now."
  • "Channel 1 tripped. What happened, and is it safe to clear the trip?"

Notes

  • Dialect detection: *IDN? manufacturer "RIGOL" → Rigol, "Siglent" → Siglent, "THURLBY THANDAR"/"TTi"/"Aim" → Aim-TTi. Force one with --option dialect=rigol|siglent|tti for rebadged units. Models not in the built-in table are treated as --option channels=N channels with no model maxima (the safety limits still apply).
  • Rigol: setpoints via :SOUR<n>:VOLT/CURR, readback via :APPL? CHn and :MEAS:ALL? CHn, mode via :OUTP:MODE? CHn (CV/CC/UR), OVP/OCP via :OUTP:OVP|OCP[:STAT|:VAL|:QUES?]. Trips are cleared with :OUTP:OVP|OCP:CLEAR, which only clears the flag. [:SOUR]:VOLT:PROT:CLE is never sent because the programming guide says it also turns the output on. DP831 CH3 is a negative output: give negative voltages (not yet verified on hardware). Over RS-232 the DP800 needs CR LF line endings (?write_termination=CRLF).
  • Siglent: SPD3303X/X-E have no programmable OVP/OCP and report output state and CV/CC only through the SYST:STAT? status word (CH1/CH2). CH3 is fixed (2.5/3.3/5 V by front-panel switch) and can only be switched on/off; its state is not readable. SPD1000X has OVP/OCP levels only (always armed, trip state not readable). The error reply format (0 No Error) is not SCPI-standard, so settings are verified by reading them back. The server pauses 0.1 s after each command to Siglent supplies (--option write_delay_s= to change); Siglent's own examples wait between commands, but the required delay is not documented.
  • Aim-TTi: there is no live CV/CC query, so mode is inferred from readback vs setpoints (mode_source: "inferred"). Trip flags come from the LSR<n>? limit event register, which latches events and is cleared by reading it. CPX/QL/PL-P protection is always armed (levels only); MX models can also switch OVP/OCP on/off. TRIPRST clears trips on all outputs (not documented for MX100T/TP). Original QL P/T models have no output-state query, so their output_on is reported as unknown. OPALL 0 is sent first in all_outputs_off, then every output individually.
  • Tracking / series / parallel modes, timers, sequences, remote sense and saved set-ups are not exposed. Put the supply in independent mode before handing it to an agent.
  • GW Instek GPP and B&K Precision 9130/9140 supplies are not supported yet: too many reply formats are undocumented in their manuals to implement them safely.

Hardware verification

ModelFirmwareInterfaceVerified byDate
none yet: be the first

Source: servers/engineering/bench-power-supply/README.md at commit 46545ea

Tools

0
SourceWeft has not started this package in its sandbox yet, so its tools are not known.

Version history

2
  1. v0.1.3LatestSep 27, 2026
  2. v0.1.1Sep 26, 2026

Score

50% of the applicable checks met

How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.

  • Reached in the last 30 days25 pts

    Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.

  • Auth declared10 pts

    Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.

  • Tools listed15 pts

    Answer tools/list without a credential, or ship a package that starts in a sandbox without one.

  • DescriptionRequired15 pts
  • Logo10 pts
  • Documentation15 pts
  • License10 pts