IKA Hotplate & Overhead Stirrer

io.github.K-Dense-AIPublished by GitHub account K-Dense-AIv0.1.1Updated Oct 24, 2026

MCP server for IKA hotplate stirrers and overhead stirrers (NAMUR commands).

VerifiedSTDIODesktop onlyDeveloper ToolsSecurity & Monitoring

Overview

AI-generated overview

An MCP server that lets an assistant control IKA hotplate stirrers and overhead stirrers over a serial or TCP NAMUR connection: read temperatures, speed and tor

What you can do
Read instrument identity, connection mode, active safety limits and the raw command log, and read plate, probe and medium temperatures, speed, torque and setpoints, including polling until a target temperature is stable.
When to use it
When an assistant should operate an IKA hotplate stirrer or overhead stirrer in a lab, for example to heat a flask to a setpoint, stir at a given speed, log a cooldown, or stop everything in an emergency.
Requirements
Python package run locally via uvx, with a serial or TCP address passed through LABMCP_ADDRESS. The instrument must be connected by USB virtual COM port or RS-232 cable at the fixed NAMUR serial settings. LABMCP_SIMULATE=1 runs a built-in simulator without hardware.
Before you install
The server can start heating and stirring and change setpoints, which is a physical hazard; keep the default safety limits and use LABMCP_READ_ONLY=1 for monitoring only. The watchdog must be re-armed after the server stops or reconnects, and mode 1 cannot be cancelled over the interface. The driver is tested only against a simulator, not real hardware.

Installation

In SourceWeft

  1. Open IKA Hotplate & Overhead Stirrer in the dashboard and add it to a workspace.
  2. Enable the server for the chats that should use its tools.

Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.

Other MCP clients

Follow the launch instructions in the repository.

README

IKA Hotplate & Overhead Stirrer — MCP Server

Let an AI agent heat and stir with IKA hotplate stirrers (C-MAG HS control, IKA Plate / RCT digital) and drive IKA overhead stirrers (EUROSTAR control) through IKA's documented NAMUR interface commands: read plate, probe and medium temperatures, speed and torque; set and start heating and stirring; wait for a temperature; and arm the hotplate's hardware watchdog so it switches itself off if the computer stops talking to it.

Packagelabmcp-ika
InstrumentsHotplate stirrers: C-MAG HS 7 control, IKA Plate (RCT digital). Overhead stirrers (--option device=overhead): EUROSTAR 60 control, EUROSTAR 100 control. Other IKA devices with the same NAMUR set are likely to work but are unverified
InterfacesRS-232 (9-pin, PC 1.1 cable), USB (virtual COM port)
ProtocolIKA NAMUR commands, "Interfaces and outputs" section of the operating instructions: IKA Plate (RCT digital) (11/2018), C-MAG HS 7 control (11/2018), EUROSTAR 60/100 control (20000003965c). Official downloads: ika.com
Status🧪 simulated: tested against a wire-level NAMUR simulator, not yet verified on hardware. Report a hardware test

Try it without hardware

bash
uvx labmcp-ika --simulate --checkuvx labmcp-ika --simulate --option device=overhead --check   # EUROSTAR simulator

Connect your stirrer

  1. Cable: USB A–B (the stirrer appears as a virtual COM port; on Windows install IKA's USB driver, linked in the manual) or the 9-pin RS-232 PC 1.1 cable. No setting on the device is needed. The interface is fixed at 9600 baud, 7 data bits, even parity, 1 stop bit, no flow control, and every command ends with a blank + CR LF.
  2. Find the port: uvx labmcp ports
  3. Test the connection:
    bash
    uvx labmcp-ika --address /dev/ttyACM0 --check                          # Linux, hotplateuvx labmcp-ika --address /dev/tty.usbmodem14101 --check                # macOSuvx labmcp-ika --address COM5 --check                                  # Windowsuvx labmcp-ika --address COM6 --option device=overhead --check         # EUROSTAR
    --check prints the name the device reports (IN_NAME).

Add to your MCP client

Claude Code

bash
claude mcp add ika -- uvx labmcp-ika --address /dev/ttyACM0 --limit max_temperature_c=120

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

json
{  "mcpServers": {    "ika": {      "command": "uvx",      "args": ["labmcp-ika", "--address", "/dev/ttyACM0", "--limit", "max_temperature_c=120"]    }  }}

Add --read-only to allow monitoring only (the stop tools stay available). For other clients: uvx labmcp config ika-stirrer --address /dev/ttyACM0 --client vscode.

Tools

ToolKindDescription
disable_watchdog🎛 controlCancel watchdog mode 2 (OUT_WD2@0) and stop the background refresh. Watchdog mode 1 has no cancel command; this tool reports an error for it.
enable_watchdog🎛 controlArm the hotplate's communication watchdog (OUT_WD1@m / OUT_WD2@m). The server then re-sends the watchdog command in the background; if the computer, this server or the cable fails, the hotplate switches heating and stirring off (mode 1) or falls back to the given safety values (mode 2) after timeout_s. Note: stopping or reconnecting the server also stops the refresh, so the watchdog trips unless you enable it again. Mode 1 cannot be cancelled over the interface.
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_status👁 readRead temperatures, stirring speed and setpoints. On hotplates: plate and external-probe temperature, temperature setpoint and the device's safety-circuit temperature. On overhead stirrers: PT1000 probe temperature, torque and the speed/torque limits set on the device.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_speed⚠️ hazardSet the stirring speed setpoint (OUT_SP_4). Does not start the motor; if it is already running, the speed changes immediately. Refused above max_speed_rpm (and, on overhead stirrers, above the speed limit set on the device).
set_temperature⚠️ hazardSet the hotplate temperature setpoint (OUT_SP_1). With an external probe connected this is the target temperature of the medium. Does not start heating; if heating is already on, the plate starts moving to the new setpoint immediately. Refused above max_temperature_c or above the device's own safety-circuit temperature.
start_heating⚠️ hazardSwitch the hotplate heater on (START_1). It heats towards the current setpoint, which is checked against max_temperature_c first. Make sure the vessel and its contents can take the setpoint temperature and that nothing flammable is near the plate.
start_stirring⚠️ hazardStart the stirring motor (START_4) at the current speed setpoint, which is checked against max_speed_rpm first. Make sure the stir bar or impeller is in place and the vessel is secured (a decoupled stir bar or an unclamped vessel can splash).
stop_all🛑 safetyEmergency stop: switch the heater off (hotplates) and stop the motor. Every stop command is sent even if one of them fails. Also ends a running wait_for_temperature.
stop_heating🛑 safetySwitch the hotplate heater off (STOP_1). Stirring continues. The plate stays hot for a long time after switching off.
stop_stirring🛑 safetyStop the stirring motor (STOP_4). Heating (if on) continues.
wait_for_temperature👁 readPoll a temperature until it is within tolerance_c of the target for stable_for_s seconds, or until timeout_s passes. Does not change anything on the device (start heating first). Returns whether the target was reached plus a short temperature trace. A stop command ends the wait early.

Safety limits

LimitDefaultMeaning
max_temperature_c150 °CHighest hotplate setpoint an agent may set (also checked before start_heating, and for the watchdog fallback temperature)
max_speed_rpm1000 rpmHighest stirring speed an agent may set (also checked before start_stirring)
max_wait_s3600 sLongest wait_for_temperature

Override at launch, e.g. --limit max_temperature_c=250 --limit max_speed_rpm=1500. On top of these, the hotplate refuses setpoints above its own safety-circuit temperature (set with the screwdriver dial on the device, read with IN_SP_3), and overhead stirrers refuse speeds above the speed limit set in the device menu (IN_SP_6); the server checks both before sending.

Example prompts

  • "Heat the round-bottom flask to 65 °C using the external probe, stir at 400 rpm, and tell me when it has been stable for a minute."
  • "Arm the watchdog with 60 s, then start heating to 80 °C. I'm leaving it running overnight."
  • "Log the medium temperature every 30 s while it cools down and tell me when it is below 30 °C."
  • "Ramp the EUROSTAR up to 300 rpm and report the torque; the mixture is getting viscous."
  • "Something smells wrong, stop everything now."

Notes

  • Two device types. The default is --option device=hotplate. Overhead stirrers need --option device=overhead; they have no heater, report their PT1000 probe on IN_PV_3 and torque on IN_PV_5. Tools that don't apply to the configured type return a clear error and send nothing.
  • No state query for the heater. The NAMUR set has no "is the heater on?" command, so get_status reports the last start/stop this server sent (heating_commanded, stirring_commanded) and None when unknown. The front-panel buttons can change it without the server knowing.
  • Setpoints are read back after set_temperature / set_speed (IN_SP_1 / IN_SP_4), and a warning is returned if the device reports a different value.
  • Watchdog (hotplates, OUT_WD1@m / OUT_WD2@m, 20–1500 s): enable_watchdog arms it and the server re-sends the command in the background every quarter of the watchdog time. If the server or the computer dies or the cable is pulled, the hotplate switches heating and stirring off (mode 1) or falls back to the safety temperature and speed (mode 2). Stopping or reconnecting the server also stops the refresh, so the watchdog trips. Mode 1 has no documented cancel command; mode 2 is cancelled with OUT_WD2@0. The manual's watchdog error codes differ between sections (ER 2 vs Err. 1/Err. 2); a trip is visible on the display, not over the interface.
  • Unverified reply layout. The IKA manuals document the commands but not the exact reply line. The driver takes the first number on the line (devices are reported to append the channel, e.g. 25.3 2), so both forms work. The value reported by IN_PV_1 when no external probe is plugged in is not documented; ignore external_temperature_c if you have no probe.
  • The IKA manuals print the terminator as "Blank CR LF (hex 0x20 0x0d 0x20 0x0A)"; the extra 0x20 contradicts the text ("Blank CR LF") and is treated as a typo, so the server sends 0x20 0x0D 0x0A.
  • Not implemented: SET_MODE_n (changes the power-on operating mode A/B/D, a persistent setting) and RESET; overhead-stirrer torque/speed-limit writes (OUT_SP_5/6/8) and direction change (OUT_MODE_n).

Hardware verification

ModelFirmwareInterfaceVerified byDate
none yet: be the first

Source: servers/chemistry/ika-stirrer/README.md at commit 46545ea

Tools

0
SourceWeft has not started this package in its sandbox yet, so its tools are not known.

Version history

2
  1. v0.1.1LatestSep 27, 2026
  2. v0.1.0Sep 26, 2026

Score

50% of the applicable checks met

How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.

  • Reached in the last 30 days25 pts

    Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.

  • Auth declared10 pts

    Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.

  • Tools listed15 pts

    Answer tools/list without a credential, or ship a package that starts in a sandbox without one.

  • DescriptionRequired15 pts
  • Logo10 pts
  • Documentation15 pts
  • License10 pts