LabJack T-series DAQ

io.github.K-Dense-AIPublished by GitHub account K-Dense-AIv0.1.3Updated Oct 24, 2026

MCP server for LabJack T4, T7/T7-Pro and T8 DAQ devices (LJM).

VerifiedSTDIODesktop onlyDeveloper ToolsData & Analytics

Overview

AI-generated overview

Local MCP server that lets an AI assistant read analog inputs, stream waveforms, read thermocouples and, with permission, drive DACs and digital outputs on LabJ

What you can do
Inspect the connection and device: report the connected LabJack, its model, serial, firmware, available inputs, ranges and digital lines, and review the raw command log or reconnect after a power cycle or cable change. Read analog inputs and device temperature once, including the internal sensor and estimated ambient temperature. Read thermocouples on T7/T8 extended features with type, measured voltage and cold-junction temperature. Read digital line levels and directions without changing them. Stream hardware-timed waveforms on analog inputs with per-channel statistics, a downsampled waveform and optional CSV export. Drive outputs: set a digital line high or low, write DAC0/DAC1 DC voltage,
When to use it
Useful when you have a LabJack T4, T7/T7-Pro or T8 on your desk and want an assistant to take measurements, log waveforms, check thermocouples or digital lines, or adjust analog and digital outputs under safety limits. The built-in simulator lets you try the workflow without hardware.
Requirements
Runs locally as a Python package (uvx labmcp-labjack) over stdio, desktop only. Needs LabJack's native LJM library and USB driver installed separately, and the device reachable over USB, Ethernet or WiFi. Configure the instrument with LABMCP_ADDRESS (serial number, IP, device name or ANY); optional LABMCP_LIMITS, LABMCP_READ_ONLY and LABMCP_SIMULATE. Close other LabJack software such as Kipling, LJLogM or LJStreamM, since a device can only be claimed by one process at a time over USB.
Before you install
Output tools change hardware state: set_digital_output and write_dac drive lines and DAC voltages, and a DAC value persists until changed or set_outputs_safe is called. Use LABMCP_READ_ONLY=1 to block state-changing tools, and set LABMCP_LIMITS to cap DAC voltage, stream duration and scan rate. Analog range and resolution settings persist on the device until changed or power-cycled. The README states the server is simulated and not yet verified on real hardware, so test carefully before relying

Installation

In SourceWeft

  1. Open LabJack T-series DAQ in the dashboard and add it to a workspace.
  2. Enable the server for the chats that should use its tools.

Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.

Other MCP clients

Follow the launch instructions in the repository.

README

LabJack T-series DAQ — MCP Server

Let an AI agent read analog inputs, stream waveforms, read thermocouples, check digital lines and (with your permission) set DACs and digital outputs on LabJack T4, T7/T7-Pro and T8 DAQ devices through LabJack's official LJM library.

Packagelabmcp-labjack
InstrumentsLabJack T4, T7, T7-Pro, T8 (and their OEM versions)
InterfacesUSB, Ethernet, WiFi (T7-Pro)
ProtocolLJM library + T-series Modbus register map (T-Series Datasheet, register map ljm_constants.json, labjack-ljm Python wrapper)
Status🧪 simulated: tested against a simulated LJM backend, not yet verified on hardware. Report a hardware test

Try it without hardware

bash
uvx labmcp-labjack --simulate --checkuvx labmcp-labjack --simulate --option sim_model=T8 --check     # T4, T7, T7-Pro (default) or T8

The simulator wires a 2 V / 10 Hz sine to AIN0, a thermistor divider (~2.5 V) to AIN1, DAC0 back into AIN2, an LM34 cold-junction sensor to AIN3, and a ~37 °C thermocouple to AIN0-AIN3 when the thermocouple feature is used. Other inputs are grounded.

Connect your LabJack

  1. Install LJM (the native library and USB driver) from labjack.com/support/software/installers/ljm. The labjack-ljm Python package is installed automatically with this server, but it needs that native library.
  2. Close other LabJack software (Kipling, LJLogM, LJStreamM). A device can only be claimed by one process at a time over USB.
  3. Test the connection:
    bash
    uvx labmcp-labjack --check                                  # first LabJack founduvx labmcp-labjack --address 470012345 --check              # by serial numberuvx labmcp-labjack --address 192.168.1.207 --option connection_type=ETHERNET --checkuvx labmcp-labjack --option device_type=T4 --check          # only open a T4
    --address is the LJM identifier: a serial number, an IP address, a device name, or ANY (the default).

Add to your MCP client

Claude Code

bash
claude mcp add labjack -- uvx labmcp-labjack --address 470012345

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

json
{  "mcpServers": {    "labjack": {      "command": "uvx",      "args": ["labmcp-labjack", "--address", "470012345"]    }  }}

Add --read-only to allow measurements but block the DAC and digital-output tools (set_outputs_safe stays available). Add --option safe_dio=FIO0,FIO1 to make set_outputs_safe always release those lines, even if another program drove them. For other clients, generate the snippet with uvx labmcp config labjack --client vscode (also cursor, codex, claude-code).

Tools

ToolKindDescription
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_device_info👁 readIdentify the connected LabJack (model, serial, firmware, connection) and list what it offers: analog inputs, valid input ranges, resolution indices, DAC range, digital lines and stream rate. Call this before configuring channels.
read_analog_inputs👁 readRead one or more analog inputs once (command-response) and return volts.
read_device_temperature👁 readRead the LabJack's internal temperature sensor (°C, about ±2 °C) and the estimated ambient air temperature. On the T8 also returns the sensor next to each AIN terminal. Cannot be read while a stream is running.
read_digital_inputs👁 readReport the logic level and direction (input/output/analog) of digital I/O lines.
read_thermocouple👁 readRead a thermocouple with the T7/T8 AIN thermocouple extended feature (types B, C, E, J, K, N, R, S, T) and return °C with the measured voltage and cold-junction temperature.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_digital_output⚠️ hazardMake a digital line an output and drive it high (3.3 V) or low (0 V).
set_outputs_safe🛑 safetyPut the outputs in a safe state: stop any stream, set DAC0 and DAC1 to 0 V, and release every digital line this server drove (plus the safe_dio option lines) to input - or drive them low with dio_mode='low'. Use when finished or if anything looks wrong.
stream_analog👁 readAcquire a hardware-timed waveform on one or more analog inputs (LJM stream mode) and return per-channel statistics plus a downsampled waveform; optionally save everything to CSV.
write_dac⚠️ hazardSet an analog output (DAC0/DAC1) to a DC voltage. The output stays at this value until changed or set_outputs_safe is called.

get_connection_info, get_command_log and reconnect are built into every LabMCP server. The command log records every LJM register read and write.

Safety limits

LimitDefaultMeaning
max_dac_voltage_v5 VHighest DAC voltage an agent may set (hardware: T4/T7 0-5 V, T8 0-10 V)
max_stream_duration_s60 sLongest hardware-timed stream
max_scan_rate_hz10 000 HzHighest stream scan rate (the device maximum still applies)

Override at launch, e.g. --limit max_dac_voltage_v=2.5. Limits are checked before anything is sent. Streams are also capped at 2 million samples in total.

Example prompts

  • "Read AIN0-AIN3 on the ±1 V range and tell me which channels look like they are floating."
  • "Stream AIN0 and AIN1 at 5 kHz for 2 seconds, give me the RMS and peak-to-peak of each, and save the data to ~/data/run12.csv."
  • "Read the type K thermocouple on AIN2 every 10 seconds for a minute and tell me whether it is still warming up."
  • "Set DAC0 to 1.25 V, then check the loopback on AIN2 and report the error in millivolts."
  • "Which digital lines are outputs right now, and what level are they at?"
  • "We're done — put all the outputs back in a safe state."

Notes

  • Model differences are enforced. Valid input ranges (AIN#_RANGE) and resolution indices come from LabJack's register map: T7 ±10/±1/±0.1/±0.01 V and index 0-8 (T7-Pro 0-12, but 9-12 cannot stream); T8 ±11 … ±0.018 V and index 0-16 (one index shared by all inputs); T4 fixed ranges (AIN0-3 ±10 V, AIN4-11 0-2.5 V) and index 0-5. DAC range: T4/T7 0-5 V, T8 0-10 V.
  • Settings persist. Range, resolution and differential settings made by read_analog_inputs stay on the device until changed or power-cycled. Omitted settings are left as they are; every reading reports what it was measured against (GND, the T7 negative input, or the T8's isolated terminal).
  • Reading digital lines never changes their direction. read_digital_inputs uses the DIO_STATE/DIO_DIRECTION bitmasks. (Reading a single-line register such as FIO3 would switch that line to input.)
  • T4 flexible I/O. AIN4-AIN11 share terminals with FIO4-EIO3. The server refuses to read those AINs while the line is a digital output, because the read would switch it to analog and release whatever it drives.
  • set_outputs_safe default is input, the T-series power-up state (input with pull-up). If an attached relay board treats a pulled-up input as "on", use dio_mode="low" instead.
  • Thermocouples use the AIN extended feature (AIN#_EF_INDEX 20-30). With cjc="internal" the CJC register is set to its documented default TEMPERATURE_DEVICE_K (address 60052), which the T8 firmware maps to each channel's own terminal sensor (TEMPERATURE#_CAPTURE); cjc="lm34" uses LabJack's LM34 conversion (55.56 K/V, 255.37 K). An open input returns valid=false (the device reports -9999).
  • Streams follow LabJack's stream_basic.py example (internal clock, no trigger, auto settling). While a stream runs, command-response analog reads are blocked by the device. Skipped scans (buffer overflow) are reported and left empty. set_outputs_safe does not wait for a running stream: it stops it at the next read (the partial result is returned with aborted: true). A stream runs at 1 scan/s or faster (so that stop is prompt) and always takes at least two scans; that real duration is what the max_stream_duration_s limit checks. The returned waveform is downsampled by keeping each block's minimum and maximum, so short spikes are not lost; save_path must be a new .csv file (an existing file is never overwritten, and the path is checked before streaming).
  • Importing the LJM wrapper prints to stdout if the native library is missing. The server redirects that import so the MCP stdio channel is never corrupted, and reports a clear install hint instead.

Hardware verification

ModelFirmwareInterfaceVerified byDate
none yet: be the first

Source: servers/engineering/labjack/README.md at commit 46545ea

Tools

0
SourceWeft has not started this package in its sandbox yet, so its tools are not known.

Version history

2
  1. v0.1.3LatestSep 27, 2026
  2. v0.1.1Sep 26, 2026

Score

50% of the applicable checks met

How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.

  • Reached in the last 30 days25 pts

    Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.

  • Auth declared10 pts

    Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.

  • Tools listed15 pts

    Answer tools/list without a credential, or ship a package that starts in a sandbox without one.

  • DescriptionRequired15 pts
  • Logo10 pts
  • Documentation15 pts
  • License10 pts