
NI-DAQmx DAQ Devices
io.github.K-Dense-AIPublished by GitHub account K-Dense-AIv0.1.2Updated Oct 24, 2026
MCP server for National Instruments DAQ devices (NI-DAQmx).
Overview
Local MCP server that lets an AI assistant read analog, digital and thermocouple signals and set outputs on National Instruments DAQ hardware via NI-DAQmx.
- What you can do
- Discover and inspect devices: list NI-DAQmx devices, report connection details, describe channels, ranges and rates, and review the raw command log or reconnect after a power cycle. Acquire analog input: take single readings or hardware-timed acquisitions with per-channel statistics and a downsampled waveform, optionally saved to a new CSV file. Read digital lines and measure thermocouple temperatures in common types. Drive outputs: set analog output voltages and digital line levels, and return all outputs to a safe state.
- When to use it
- Useful for bench, lab or test setups where an assistant should query NI DAQ hardware, capture measurements, log data to CSV, or toggle analog and digital outputs under explicit safety limits. It is also usable without hardware through a built-in simulator.
- Requirements
- Runs locally as a Python package (uvx labmcp-ni-daqmx) on Windows or Linux; macOS is not supported by NI-DAQmx. Requires the NI-DAQmx driver installed and a device name passed via --address (optional when exactly one device is present). Optional environment variables: LABMCP_ADDRESS, LABMCP_LIMITS, LABMCP_READ_ONLY, LABMCP_SIMULATE. Desktop only.
Installation
In SourceWeft
- Open NI-DAQmx DAQ Devices in the dashboard and add it to a workspace.
- Enable the server for the chats that should use its tools.
Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.
Other MCP clients
Follow the launch instructions in the repository.
README
NI-DAQmx DAQ Devices — MCP Server
Let an AI agent acquire voltages and thermocouple temperatures, read digital lines and (with your permission) set analog and digital outputs on National Instruments DAQ hardware through the official NI-DAQmx driver and its Python API.
Try it without hardware
The built-in simulator is a USB-6341-like X Series device Dev1: a 1 V / 50 Hz sine on ai0, a 2.5 V sensor on ai1, ao0/ao1 looped back to ai2/ai3, a ~37 °C thermocouple on ai4, and an external "interlock" holding port1/line0 high. It reproduces NI-DAQmx behaviour such as error codes (e.g. -200170 channel does not exist, -200576 no built-in CJC) and the shapes task.read() returns.
Testing the real NI-DAQmx path without hardware: in NI MAX (Windows) choose Devices and Interfaces → Create New… → Simulated NI-DAQmx Device, then run the server without --simulate against that device, e.g. --address SimDev1. NI MAX simulated devices return synthetic data, and get_connection_info reports ni_max_simulated_device: True. On Linux, simulated-device support is limited (NI's configuration tools can import a configuration file that defines one, with mixed results); use --simulate there.
Connect your instrument
- Install NI-DAQmx (Windows or Linux; macOS is not supported by NI-DAQmx) from ni.com. The
nidaqmxPython package is installed with this server;python -m nidaqmx installdrivercan also install the driver. - Find the device name in NI MAX (Devices and Interfaces) or with
nilsdevon Linux, e.g.Dev1orcDAQ1Mod1. Close NI MAX test panels before connecting. - Test the connection:
--addressis the NI-DAQmx device name. It is optional when exactly one device exists.
Add to your MCP client
Claude Code
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
Add --read-only to allow acquisitions but block the output tools (set_outputs_safe stays available). Add --option safe_do_lines=port0/line0:3 to make set_outputs_safe always drive those lines low. For other clients, generate the snippet with uvx labmcp config ni-daqmx --address Dev1 --client vscode (also cursor, codex, claude-code).
Tools
get_connection_info, get_command_log and reconnect are built into every LabMCP server. The command log records every task the server ran (channels, ranges, rates, values written).
Safety limits
Override at launch, e.g. --limit max_ao_voltage_v=10 --limit max_acquisition_s=300. Limits are checked before anything is sent. The device's own AO range is also enforced (e.g. USB-6008/6009 outputs 0-5 V only), as are its maximum sample rates.
Example prompts
- "List the NI devices and tell me which inputs Dev1 has and their voltage ranges."
- "Acquire ai0 and ai1 differentially at 10 kHz for 0.5 s on the ±1 V range and give me the RMS noise of each; save the data to ~/daq/noise.csv."
- "Read the type K thermocouples on cDAQ1Mod1/ai0:3 once a second for 30 seconds using the built-in CJC and report the average of each."
- "Set ao0 to 2.0 V, confirm it on the ai2 loopback, then set it back to 0."
- "Is the interlock on port1/line0 closed? Then switch port0/line2 high to open the valve."
- "We're done: put every output in a safe state."
Notes
- Every tool call is one short DAQmx task (create channels, configure timing, read or write, close), as in NI's examples, so the server never holds the device reserved between calls. Another program using the device at the same time causes a clear "resource reserved" error (-50103). Output and digital-line tasks are serialised separately from acquisitions, so
set_outputs_safe(andwrite_analog) never wait for a running acquisition to finish: NI-DAQmx runs an analog-input task and AO/DIO tasks on the same device side by side. - Acquisitions are capped at 600 s per tool call even if
max_acquisition_sis raised. The returned waveform is downsampled by keeping each block's minimum and maximum, so short spikes are not lost.save_pathmust be a new.csvfile: it is checked before acquiring, and an existing file is never overwritten. - Outputs hold their value after the task closes on most NI devices, which is what the output tools rely on. Some devices have configurable idle/power-up output behaviour; check your device if it resets outputs.
- Reading a digital line can change it. A DAQmx digital-input task configures the line as an input. The server therefore reports lines it is driving from their last commanded level instead of reading them, and documents the risk for lines driven by other software.
- Terminal configuration matters.
defaultlets NI-DAQmx choose (often differential where supported). A wrong choice gives offsets or noise rather than an error. - Thermocouples use
add_ai_thrmcpl_chanwith built-in or constant cold-junction compensation. A CJC channel (SCANNABLE_CHANNEL) is not offered in this version because its correct use depends on the device. - Rates: multiplexed devices share
ai_max_multi_channel_rate_hzacross channels, and NI-DAQmx coerces the sample clock to a rate the timebase can produce. The actual rate is returned insample_rate_hz. - NI-DAQmx warnings (e.g. about coerced values) are returned in each acquisition's
warningslist.
Hardware verification
Source: servers/engineering/ni-daqmx/README.md at commit 46545ea
Tools
0Version history
2- v0.1.2LatestSep 27, 2026
- v0.1.0Sep 26, 2026
Score
50% of the applicable checks met
How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.
- Reached in the last 30 days25 pts
Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.
- Auth declared10 pts
Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.
- Tools listed15 pts
Answer tools/list without a credential, or ship a package that starts in a sandbox without one.
- DescriptionRequired15 pts
- Logo10 pts
- Documentation15 pts
- License10 pts