PalmSens Potentiostat

io.github.K-Dense-AIPublished by GitHub account K-Dense-AIv0.1.3Updated Oct 24, 2026

MCP server for PalmSens potentiostats running MethodSCRIPT (EmStat Pico, EmStat4, Sensit, Nexus).

VerifiedSTDIODesktop onlyDeveloper ToolsData & Analytics

Overview

AI-generated overview

Local MCP server that lets an AI assistant run electrochemistry measurements on PalmSens MethodSCRIPT potentiostats and get back data, peaks and CSV files.

What you can do
  • Run cyclic, linear sweep and differential pulse voltammetry, plus chronoamperometry, with peak and current summaries
  • Run raw MethodSCRIPT scripts and read back raw output and decoded data packages
  • Inspect the instrument: model, firmware, serial, potential window, PGStat modes and current ranges
  • Check connection state, read-only mode and active safety limits, and review the raw command log
  • Abort a running measurement, reconnect after a power cycle, and save results to CSV files
When to use it
For lab work where an assistant should drive a PalmSens potentiostat directly: routine CV, LSV, DPV or chronoamperometry runs, scan-rate studies, peak and charge summaries, or scripted MethodSCRIPT experiments. The built-in simulator lets you try the workflow without hardware.
Requirements
Runs locally as a Python package (labmcp-palmsens, typically via uvx) over stdio. Needs a supported PalmSens instrument reachable by USB serial or UART, set with LABMCP_ADDRESS; the serial port must be free, so PSTrace or MultiTrace has to be closed. Optional LABMCP_LIMITS, LABMCP_READ_ONLY and LABMCP_SIMULATE variables tune limits, read-only mode and simulation.
Before you install
Measurement tools apply potential to an electrochemical cell, which is a physical action on real hardware; keep LABMCP_LIMITS conservative and consider LABMCP_READ_ONLY when only device information is needed. Raw scripts are only partly checked, since values computed at run time are not validated against the limits. The server is tested only against a simulator, not verified on hardware. CSV output never overwrites an existing file.

Installation

In SourceWeft

  1. Open PalmSens Potentiostat in the dashboard and add it to a workspace.
  2. Enable the server for the chats that should use its tools.

Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.

Other MCP clients

Follow the launch instructions in the repository.

README

PalmSens Potentiostat — MCP Server

Let an AI agent run cyclic voltammetry, linear sweep voltammetry, differential pulse voltammetry and chronoamperometry on PalmSens potentiostats that speak MethodSCRIPT, and get back downsampled data, peak summaries and optional full-resolution CSV files.

Packagelabmcp-palmsens
InstrumentsEmStat Pico (module and development board), EmStat4 LR/HR (EmStat4S, EmStat4M, EmStat4X), Sensit Wearable / Sensit BT, Nexus
InterfacesUSB (virtual COM port), UART
ProtocolMethodSCRIPT v1.x (MethodSCRIPT manual v1.8) over the PalmSens online communication protocol (EmStat Pico v1.6, EmStat4 v1.3); cross-checked against PalmSens/MethodSCRIPT_Examples
Status🧪 simulated: tested against a wire-level simulator, not yet verified on hardware. Report a hardware test

Try it without hardware

bash
uvx labmcp-palmsens --simulate --check

The simulator is an EmStat Pico with a 3 mm disk electrode in 1 mM of a reversible one-electron redox couple (E° = +0.20 V, like ferro/ferricyanide vs Ag/AgCl). It interprets the scripts the server sends and streams correctly encoded data packages, so you get a proper CV "duck", DPV peaks and Cottrell decays. Simulated time runs 10× faster than real time; change that with --option sim_speed=1 (real time) or =100.

Connect your instrument

  1. Close PSTrace / MultiTrace. Only one program can hold the serial port.
  2. Find the port: uvx labmcp ports. An EmStat Pico development board or Sensit shows up as a USB serial port (FTDI). An EmStat4 or Nexus shows up as a virtual COM port named after the device.
  3. Test the connection:
    bash
    uvx labmcp-palmsens --address /dev/ttyUSB0 --check            # EmStat Pico / Sensit (Linux)uvx labmcp-palmsens --address /dev/tty.usbmodemXXXX --check   # EmStat4 (macOS)uvx labmcp-palmsens --address COM7 --check                    # Windows
    Defaults are the EmStat Pico's: 230400 baud, 8N1, XON/XOFF, LF line endings. Over USB the EmStat4 and Nexus ignore the baud rate. For an EmStat4 UART connection use serial://COM7?baudrate=921600&rtscts=true&xonxoff=false.
  4. --check sends the firmware-version (t) and serial-number (i) commands and prints the model, firmware and serial.

Add to your MCP client

Claude Code

bash
claude mcp add potentiostat -- uvx labmcp-palmsens --address /dev/ttyUSB0

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

json
{  "mcpServers": {    "potentiostat": {      "command": "uvx",      "args": ["labmcp-palmsens", "--address", "/dev/ttyUSB0"]    }  }}

Add --read-only to allow device information only: every measurement tool applies potential and is hidden.

Tools

ToolKindDescription
abort_measurement🛑 safetyAbort the running measurement or script immediately (communication command Z) and make sure the cell is switched off. Safe to call when nothing is running.
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_device_info👁 readIdentify the potentiostat (model, firmware, serial number) and list its potential window, PGStat modes and current ranges, so measurement parameters can be chosen within them.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
run_chronoamperometry⚠️ hazardHold the cell at potential_v for run_time_s and record the current every interval_s. Returns the data (time from the instrument timer) plus first/last/mean current and the charge. Applies potential to the cell.
run_cyclic_voltammetry⚠️ hazardRun a cyclic voltammogram: begin -> vertex 1 -> vertex 2 -> begin, n_scans times, and return potential/current/time data with the anodic and cathodic peaks of every scan. Applies potential to the cell for the whole scan; the cell is switched off at the end.
run_differential_pulse_voltammetry⚠️ hazardRun differential pulse voltammetry (current = forward - reverse, per step) from begin to end potential and return the data with the peak current and peak potential. The scan rate must be below step / pulse_time / 2. Applies potential to the cell.
run_linear_sweep_voltammetry⚠️ hazardRun a linear sweep voltammogram from begin_potential_v to end_potential_v and return the data with the largest/smallest current and where they occur. Applies potential to the cell.
run_methodscript⚠️ hazardAdvanced: run a raw MethodSCRIPT and return its raw output and decoded data packages. Literal potentials of set_e / set_range_minmax da and the CV, LSV, DPV, SWV, NPV, ACV, CA, PAD, EIS and fast CV/CA techniques are checked against max_potential_v, and literal set_range ba / set_autoranging ba currents against max_current_range_a; values computed at run time are not. Aborted after timeout_s; add on_finished: + cell_off to your script so the cell is switched off after an abort. After a runtime error, a timeout or abort_measurement the server switches the cell off itself.

Safety limits

LimitDefaultMeaning
max_potential_v2.0 VLargest absolute potential vs RE any technique (or literal in a raw script) may apply, including DPV pulses
max_current_range_a0.01 AHighest current range an agent may select (with autorange, the instrument never goes above current_range_a); in raw scripts, literal set_range ba / set_autoranging ba values
max_duration_s600 sLongest measurement (including equilibration) or raw-script timeout

Override at launch, e.g. --limit max_potential_v=1.0 --limit max_duration_s=1800. Whatever the limits say, a single tool call is capped at one hour.

Example prompts

  • "Run a CV of my ferrocyanide sample from −0.2 V to +0.6 V and back at 50 mV/s, three cycles, and tell me E½ and the peak separation."
  • "Do a scan-rate study: CVs at 25, 50, 100 and 200 mV/s between −0.1 and 0.5 V, save each as CSV, and check whether the peak current scales with √v."
  • "Run DPV from 0 to 0.6 V with 50 mV pulses and report the peak potential and height."
  • "Hold 0.5 V for 60 s, record the current every 0.2 s, and give me the total charge passed."
  • "Which potential window and current ranges does this potentiostat support?"
  • "Abort the measurement."

Notes

  • What the server sends. Each technique is one MethodSCRIPT modelled on PalmSens' measurement-loop examples: set_pgstat_chan 0, set_pgstat_mode, set_max_bandwidth, set_range_minmax da, set_range ba, set_autoranging ba, set_e, cell_on, optional wait, then meas_loop_cv / lsv / dpv / ca with pck_add of the set potential and current, and on_finished: cell_off. So the cell is switched off after completion and after an abort. A runtime error skips on_finished: (MethodSCRIPT manual §10.1), so after one the server sends a separate cell_off script. The exact script is in get_command_log.
  • PGStat mode and bandwidth. Max bandwidth is 6× the data rate (the ratio PalmSens' examples use). On the EmStat Pico and Sensit, the server picks low speed (−1.25 to 2.0 V, 2.2 V window, ≤ 100 Hz), then max range (−1.7 to 2.0 V, 2.6 V window), then high speed (1.214 V window) to fit your potentials. If none fits, it says why before anything is sent. EmStat4 and Nexus use low speed mode; per the manual, the modes do not differ on those instruments.
  • Current sign and units. Anodic (oxidation) current is positive; potentials are the set potentials vs RE; time_s comes from the instrument timer for chronoamperometry and from step/scan rate for sweeps.
  • Summaries. CV peaks are the raw maximum and minimum current of each scan (no baseline correction). ΔEp and the midpoint are estimates. Staircase sampling makes ΔEp somewhat larger than the ideal 59 mV at large steps.
  • Raw scripts. run_methodscript checks literal potentials (and store_var literals) of set_e, set_range_minmax da and the CV/LSV/DPV/SWV/NPV/ACV/CA/PAD/EIS loops and meas_fast_cv/meas_fast_ca against max_potential_v (DPV pulse and 2x SWV amplitude included). Literal current ranges of set_range ba / set_autoranging ba are checked against max_current_range_a. Values computed inside the script are not checked. The script is aborted at timeout_s and a cell_off script is run.
  • Abort. abort_measurement sends the communication-protocol Z command. A running technique returns the data measured so far with aborted: true. Afterwards (and when nothing was running) the server runs a one-line cell_off script, so the cell is also switched off after a raw script without on_finished:. If the output of a running script cannot be read (e.g. a USB glitch), the server aborts the script and switches the cell off before reporting the error; a single corrupted data line is skipped with a warning instead.
  • Saving data. save_path must end in .csv; missing folders are created and an existing file is never overwritten (choose a new name). The path is checked before the measurement starts. Points with a nan value are left out (with a warning).
  • Not covered: galvanostatic techniques, EIS, SWV/NPV/PAD, multiplexers, bipotentiostat mode, multi-channel MultiEmStat4 systems and the CRC16 protocol extension. Use run_methodscript for single-channel scripts beyond the built-in techniques.

Hardware verification

ModelFirmwareInterfaceVerified byDate
none yet: be the first

Source: servers/chemistry/palmsens-potentiostat/README.md at commit 46545ea

Tools

0
SourceWeft has not started this package in its sandbox yet, so its tools are not known.

Version history

2
  1. v0.1.3LatestSep 27, 2026
  2. v0.1.1Sep 26, 2026

Score

50% of the applicable checks met

How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.

  • Reached in the last 30 days25 pts

    Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.

  • Auth declared10 pts

    Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.

  • Tools listed15 pts

    Answer tools/list without a credential, or ship a package that starts in a sandbox without one.

  • DescriptionRequired15 pts
  • Logo10 pts
  • Documentation15 pts
  • License10 pts