Sartorius Balance

io.github.K-Dense-AIPublished by GitHub account K-Dense-AIv0.1.2Updated Oct 24, 2026

MCP server for Sartorius laboratory balances (SBI protocol).

VerifiedSTDIODesktop onlyDeveloper ToolsData & Analytics

Overview

AI-generated overview

Controls Sartorius laboratory balances over the SBI protocol to read weights, tare, zero, log drift, and run internal adjustment.

What you can do
Exposes tools that read the current net weight, tare or zero the balance, and log a series of immediate readings with summary statistics for drift, evaporation, or stabilisation checks. It can also lock the keypad, set ambient-condition filters, run internal adjustment on isoCAL models, reconnect after a power cycle, and return the raw command log and connection details. Communication uses the documented SBI ASCII protocol over serial or Ethernet.
When to use it
Useful when an assistant should operate a Sartorius balance directly: weighing out a target mass, taring a container, monitoring evaporation or drift over time, or running an internal adjustment before a measurement series. It is aimed at lab benches with a supported balance and a serial or Ethernet connection.
Requirements
Runs locally as a Python package (uvx labmcp-sartorius) over stdio; desktop only. Needs a supported Sartorius balance reachable by RS-232, USB virtual COM port, or Ethernet, configured for the SBI protocol with manual output. Set LABMCP_ADDRESS to the instrument address; LABMCP_SIMULATE=1 runs a built-in simulator with no hardware. No accounts or API keys.
Before you install
State-changing tools tare, zero, adjust, lock the keypad, and change filters; LABMCP_READ_ONLY=1 disables them. Internal adjustment requires an empty, undisturbed pan and SBI sends no completion message, so the result must be confirmed on the display or GLP printout. The project is tested only against a simulator, not verified on hardware, and identity reply formats are undocumented. LABMCP_LIMITS overrides safety limits such as max_series_duration_s.

Installation

In SourceWeft

  1. Open Sartorius Balance in the dashboard and add it to a workspace.
  2. Enable the server for the chats that should use its tools.

Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.

Other MCP clients

Follow the launch instructions in the repository.

README

Sartorius Balance — MCP Server

Let an AI agent weigh samples, tare containers, log drift and evaporation, and run internal adjustments on Sartorius laboratory balances through the documented SBI (Sartorius Balance Interface) ASCII protocol.

Packagelabmcp-sartorius
InstrumentsCubis MSE, Cubis II MCA, Secura, Quintix, Practum, Entris II; older CP/CPA-series balances with --option legacy=true. Other SBI balances are likely to work
InterfacesRS-232, USB (virtual COM port, "PC-SBI"), Ethernet (Cubis II "serial transmission via Ethernet", or any serial-to-Ethernet adapter)
ProtocolSBI: Entris II interface description (technical note 10/2020), Secura/Quintix/Practum user manual §10.3 (WSE6004), Cubis MSE operating instructions (WMS6004), Cubis MCA operating instructions (WMC6028), SBI interface description (98647-000-53)
Status🧪 simulated: tested against a wire-level SBI simulator, not yet verified on hardware. Report a hardware test

Try it without hardware

bash
uvx labmcp-sartorius --simulate --check

Connect your balance

  1. Balance setup: set the interface you use (RS232, USB-B / "PC-SBI", or Ethernet) to the SBI protocol, and set SBI data output to manual, without stability with automatic output off (factory settings on Cubis II and Entris II). With auto print on, ESC P toggles the automatic output instead of sending one reading. Either line format works (16 characters, or 22 with ID code).
  2. Serial settings: factory settings are 9600 baud, 8 data bits, odd parity, 1 stop bit, hardware handshake (Cubis II/MSE, Secura/Quintix/Practum, Entris II). The server uses these but does not enforce RTS/CTS (it keeps RTS asserted, which lets the balance transmit; USB virtual COM ports often never assert CTS). Add ?rtscts=true to enforce it, or e.g. ?bytesize=7&parity=E if your balance is set differently.
  3. Find the port: uvx labmcp ports
  4. Test the connection:
    bash
    uvx labmcp-sartorius --address /dev/ttyUSB0 --check                 # Linuxuvx labmcp-sartorius --address /dev/tty.usbmodem14201 --check       # macOSuvx labmcp-sartorius --address COM4 --check                         # Windowsuvx labmcp-sartorius --address tcp://192.168.1.61:49155 --check     # Cubis II via Ethernet (port as configured)
    --check prints the model, serial number and software version (ESC x1_, x2_, x3_) when the balance supports them.

Add to your MCP client

Claude Code

bash
claude mcp add balance -- uvx labmcp-sartorius --address /dev/ttyUSB0

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

json
{  "mcpServers": {    "balance": {      "command": "uvx",      "args": ["labmcp-sartorius", "--address", "/dev/ttyUSB0"]    }  }}

Add --read-only to allow weighing but block taring, zeroing and adjustment. For other clients: uvx labmcp config sartorius-balance --address /dev/ttyUSB0 --client vscode.

Tools

ToolKindDescription
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
lock_keypad🎛 controlBlock or unblock the balance keys, e.g. so nobody tares by accident during a long logging run.
log_weight_series👁 readRecord a series of immediate (unfiltered) readings to monitor drift, evaporation, moisture uptake or stabilisation. Returns every reading plus summary statistics.
read_weight👁 readRead the current net weight from the balance (ESC P). With stable=True the server polls until the balance reports a stable value; if it cannot settle (draughts, vibration, evaporation) you get an error; retry, or use stable=false for the current value.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
run_internal_adjustment🎛 controlAdjust (calibrate) the balance with its built-in weight (ESC Z; isoCAL models only). The pan must be empty and the balance undisturbed. SBI sends no completion message, so the server watches for the adjustment status and waits until the balance weighs again; check observed_adjustment and the balance display or GLP printout for the result.
set_ambient_conditions🎛 controlAdapt the balance's filter to the ambient conditions (ESC K/L/M/N). Use 'unstable' or 'very_unstable' for draughty or vibrating benches (slower but steadier readings).
tare🎛 controlTare the balance (ESC U, or ESC T on legacy balances): the current load (e.g. an empty container) becomes the tare. Then waits for a stable reading and checks that it is ~0; returns that reading.
zero🎛 controlZero the balance (ESC V). Only works with the pan (nearly) empty, within the balance's zero-setting range; clears the tare. Confirms by reading ~0 afterwards.

Safety limits

LimitDefaultMeaning
max_series_duration_s600 sLongest weight-logging series an agent may start

Override at launch: --limit max_series_duration_s=3600. Whatever the limit says, a single series is capped at one hour (the tool's time limit). No tool of this server moves anything or heats, so there are no hazard tools.

Example prompts

  • "Tare the balance, then tell me the weight once it's stable after I add the sample."
  • "Log the weight every 10 s for 5 minutes and tell me the evaporation rate in mg/min."
  • "Weigh out ~250 mg: tell me how much more to add, reading every few seconds, until I'm within ±2 mg."
  • "The bench is vibrating today; switch the balance filter to unstable conditions and lock the keypad."
  • "Run an internal adjustment before we start the calibration curve and tell me whether it ran."

Notes

  • Stability comes from the unit symbol. SBI has no explicit stability flag: the balance only sends the unit symbol (positions 12–14) when the reading is stable ("If the weighing system has not stabilized, no unit symbol is output", interface description 98647-000-53; the newer manuals list those positions as "unit symbol or space"). read_weight(stable=true) therefore polls ESC P until a reading with a unit arrives. Unstable readings report the last unit seen.
  • Line formats. The parser follows the documented fixed-width layouts: 16 characters (sign, value in positions 2–10, unit in 12–14, CR LF) and 22 characters (6-character ID code such as N, G#, T, Stat, then the same 16). It also accepts the Cubis II "one line with full length" format, a decimal comma, and a G#/T/N weighing block (the N line is reported). High, Low, Err ###, APP.ERR, DIS.ERR and PRT.ERR are reported as clear errors.
  • No acknowledgements. SBI control commands (ESC U tare, ESC V zero, ESC Z adjust, ESC K–N filter, ESC O/R keys) produce no reply, so a balance that does not support one silently ignores it. tare and zero therefore wait for a stable reading and check it is ~0, and report an error otherwise.
  • Zero vs tare. ESC V only zeroes within the balance's zero-setting range (nearly empty pan); ESC U tares any load. Older balances (CP/CPA, LE, ...) only have ESC T (the tare key): start the server with --option legacy=true.
  • Internal adjustment (unverified). ESC Z starts isoCAL on balances with a built-in weight. SBI sends no completion or result message; the server watches for the Cal. status (or a balance too busy to answer) and waits for a stable weight again, and reports observed_adjustment=false if it never sees one. Confirm the result on the display or GLP printout. The exact status output during adjustment could not be verified in the manuals.
  • Identity replies (unverified format). ESC x1_/x2_/x3_ print the model, serial number and software version; their exact layout is not documented, so the text is passed through as sent.
  • The command log shows SBI traffic as hex (1b 50 0d 0a = ESC P CR LF) because of the ESC character.
  • Not implemented: draft-shield and ionizer commands (Cubis MSE only), external adjustment (ESC W, needs a reference weight), ESC S restart and the function-key commands.

Hardware verification

ModelFirmwareInterfaceVerified byDate
none yet: be the first

Source: servers/chemistry/sartorius-balance/README.md at commit 46545ea

Tools

0
SourceWeft has not started this package in its sandbox yet, so its tools are not known.

Version history

2
  1. v0.1.2LatestSep 27, 2026
  2. v0.1.0Sep 26, 2026

Score

50% of the applicable checks met

How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.

  • Reached in the last 30 days25 pts

    Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.

  • Auth declared10 pts

    Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.

  • Tools listed15 pts

    Answer tools/list without a credential, or ship a package that starts in a sandbox without one.

  • DescriptionRequired15 pts
  • Logo10 pts
  • Documentation15 pts
  • License10 pts