Generic SCPI Instrument
io.github.K-Dense-AIPublished by GitHub account K-Dense-AIv0.1.3Updated Oct 27, 2026
Generic MCP server for any SCPI instrument over VISA, TCP or serial, with command allow/deny lists.
Overview
Local MCP server that lets an assistant send SCPI queries and commands to almost any lab instrument over VISA, TCP or serial, with command allow/deny lists.
- What you can do
- Identify the instrument, list visible VISA resources and report connection details, read-only status and active limits
- Send single read-only SCPI queries and read IEEE 488.2 binary blocks such as waveforms or screenshots, optionally saving them to a file
- Send SCPI program messages or short command batches, reset the instrument, and wait for pending operations to complete
- Recover a stuck instrument with device clear or reconnect, and apply a configured safe state
- Read and clear the instrument error queue and review a log of raw commands and replies
- Show a SCPI syntax primer together with the active command policy
- When to use it
- Useful when you want an assistant to drive bench instruments such as multimeters, oscilloscopes, power supplies, source-measure units or function generators that speak SCPI, especially brands without an official MCP server. It is also handy for scripted measurement runs, waveform capture and debugging instrument errors.
- Requirements
- Runs locally as a Python package (uvx labmcp-scpi) over stdio; desktop only. Needs the instrument address in LABMCP_ADDRESS or the address argument, plus a reachable interface: GPIB, USBTMC, LAN VXI-11/HiSLIP or raw socket, or RS-232. PyVISA and a VISA backend are used; NI-VISA is optional. A built-in simulator (LABMCP_SIMULATE) allows testing without hardware.
Installation
In SourceWeft
- Open Generic SCPI Instrument in the dashboard and add it to a workspace.
- Enable the server for the chats that should use its tools.
Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.
Other MCP clients
Follow the launch instructions in the repository.
README
Generic SCPI Instrument — MCP Server
Let an AI agent talk to any IEEE 488.2 / SCPI instrument: multimeters, oscilloscopes, source-measure units, power supplies, electronic loads, function generators, spectrum analyzers and counters. It works over GPIB, USBTMC, LAN (VXI-11, HiSLIP, raw socket) and RS-232. Because the agent writes raw SCPI, the server puts the safety in the plumbing. The read path accepts only single queries. Anything that changes the instrument goes through tools the MCP client asks you to confirm. You can give the server command allow and deny lists and a safe-state command of your own.
Keysight or Rohde & Schwarz instrument? Use the vendor's official MCP server instead: Keysight MCP Server for Instrument Control or the MCP server that ships with RsInstrument (
python -m RsInstrument.mcp).labmcp-scpicovers everything else: Tektronix/Keithley, Rigol, Siglent, SRS, Aim-TTi, B&K Precision, GW Instek, older HP/Agilent GPIB gear, and more.
Try it without hardware
The simulator is a small, generic bench instrument (*IDN? → LabMCP,SIM-DMM-PSU,SIM000001,1.0.0). It is a 0–30 V / 3 A supply driving a 100 Ω load, with a built-in DMM across the load. It supports MEASure:VOLTage:DC?, CONFigure + READ?/FETCh?, [SOURce:]VOLTage/CURRent, OUTPut[:STATe], TRIGger:COUNt, FORMat[:DATA] REAL,32|64 binary blocks, FORMat:BORDer, *ESR?/*STB?, and a 10-entry SYSTem:ERRor? queue (overflow gives -350). In --simulate mode, the safe state is OUTP OFF.
Connect your instrument
- Instrument setup: enable the remote interface you want to use.
- LAN: set a fixed IP address. Enable VXI-11/HiSLIP (for VISA) or the SCPI raw-socket server. Many instruments use port 5025 for the socket; check the LAN settings page or the manual.
- USB: select USBTMC / "USB device (TMC)", not "USB mass storage" or a virtual COM port.
- GPIB: note the instrument's GPIB address.
- RS-232: set the baud rate, parity and handshake, and select SCPI as the language if the instrument asks.
- Find it:
uvx labmcp ports, or ask the agent to runlist_visa_resources. That tool works without--addressand lists VISA resources through pyvisa-py; passbackend=@ivito use NI-VISA or another vendor VISA library. - Test the connection:
--checkprints the parsed*IDN?reply. If it times out, check the terminator: SCPI uses LF by default, and some serial instruments needread_termination=CRLF. Also check the baud rate, and that the instrument is set to SCPI rather than an emulation language.
Add to your MCP client
Claude Code
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
Add --read-only to allow only queries. In read-only mode scpi_write, scpi_batch and reset_instrument disappear. device_clear and apply_safe_state stay available. Run one server per instrument, each with its own key (scope, psu, dmm, …).
Tools
get_connection_info, get_command_log and reconnect are built into every LabMCP server. apply_safe_state is listed only when a safe state is configured.
Command policy
A generic server cannot know which SCPI commands are dangerous on your instrument. It enforces what it can and lets you add the rest:
Matching rules:
- Patterns are Python regular expressions, matched case-insensitively.
- Each
;-separated message unit is checked in two forms. The first is the unit as sent, upper-cased, with collapsed whitespace and no leading colon. The second reduces every mnemonic to its SCPI short form (SCPI-99 Vol. 1 §6.2.1)::OUTPut1:STATe ONbecomesOUTP1:STAT ON. So^OUTP\d*(:STAT)? (?!OFF\b)catchesOUTP ON,outp:stat 1,VOLT 5;:OUTPut:STATe ONandOUTPut2 ON. - SCPI booleans accept any number (it is rounded, and anything non-zero means ON), so
OUTP 2,OUTP 1.0andOUTP #H1also switch an output on. Deny "everything except OFF", as above, rather than listing(ON|1). - The denylist uses
re.search. It also resolves relative headers (OUTP:POL NORM;STAT ONis checked asOUTP:STAT ON) and splits at every;, even inside quotes. The allowlist must match a whole unit. - Every step of
scpi_batchis checked before the first step is sent.
Examples:
The environment variable LABMCP_OPTIONS splits on commas. For regular expressions that contain commas, pass them on the command line or give LABMCP_OPTIONS as a JSON object ({"write_denylist": "..."}).
Safety limits
Override at launch: --limit max_block_bytes=67108864. This server has no voltage or current limits because it cannot interpret arbitrary commands. Set limits on the instrument itself (OVP/OCP, compliance, output protection), use a denylist, or use an instrument-specific server.
Example prompts
- "What instrument is connected? Read its identity and check the error queue."
- "Configure the DMM for DC volts on the 10 V range, take 20 readings, and give me the mean and standard deviation."
- "Set the supply to 3.3 V with a 200 mA current limit, read both back, but don't enable the output yet."
- "Grab channel 1's waveform from the scope as a binary block, save it to ~/data/ch1.csv, and summarise min, max and mean."
- "We got a -222 error. What does it mean, and which of the last commands caused it?"
- "Something's wrong: apply the safe state, then clear the interface."
Notes
- A generic server cannot make an arbitrary instrument safe.
device_cleardoes four things: a VISA device clear (on raw socket and serial links it only discards unread input), reads the error queue, sendsABORt, and sends*CLS. It recovers communication and stops sweeps. It does not switch outputs off. Configuresafe_statefor anything that sources energy. For hazardous gear, use an instrument-specific LabMCP server where one exists: it can enforce real setpoint limits. - Queries are not always read-only. On source-measure units such as the Keithley 2400,
MEASure?,READ?,INITiateandCONFigurecan switch the source output on (Keithley 2400 Series SourceMeter User's Manual, 2400S-900-01 Rev. G, §11 and §17). In--read-onlymode,scpi_querytherefore refusesMEASure?andREAD?by default, whileFETCh?still returns the last reading. Set--option allow_measure_in_read_only=trueif the instrument is a meter that cannot source. When not read-only, add--option query_denylist=^(MEAS|READ)for SMUs so these commands need confirmation throughscpi_write. *RST: SCPI-99 Vol. 2 §15.12 requiresOUTPut:STATe OFFafter*RST. But*RSTalso resets levels, ranges, limits and trigger settings, and not every instrument complies.- The error queue is read (and so cleared) after every
scpi_write/scpi_batchstep. The errors appear in the result. A query the instrument doesn't recognise produces no reply: the server times out (5 s by default,--timeoutto change), resynchronises, and reports the-113from the queue. - Instruments that don't implement
SYSTem:ERRor?(some older IEEE 488.2-only gear) reporterror_check: "unavailable". Set--option error_query=…if your instrument uses a different error query. query_binary_blockreads definite-length blocks (#<n><len><data>) only. Indefinite#0blocks are refused. Byte order followsFORMat:BORDer(NORMal = big-endian).timeout_scovers the whole transfer. Decoded NaN and infinite values are returned asnull(and counted innon_finite); the saved CSV keeps them asnan/inf.save_pathmust end in.csv(decoded values withdecode_as, otherwise the raw bytes),.bin,.dat,.raw,.txtor an image extension (.png,.bmp,.jpg,.jpeg,.gif,.tif,.tiff).~is expanded and missing folders are created. An existing file is never replaced unless you passoverwrite=true, and the check happens before anything is sent to the instrument.scpi_batchstops starting new steps after about 14 minutes (its tool timeout is 15 minutes). Steps that were not sent are markednot_run.- Text is sent as ASCII. Commands with control or non-ASCII characters are refused, and the server adds the LF terminator.
- A denylist is a guard rail, not a guarantee. It matches text, so vendor-specific aliases or macros (
*DMC, user-defined sequences) can evade it. Keep the instrument's own protection limits set.
Hardware verification
Source: servers/protocols/scpi-instrument/README.md at commit 46545ea
Tools
0Version history
2- v0.1.3LatestSep 27, 2026
- v0.1.1Sep 26, 2026
Score
50% of the applicable checks met
How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.
- Reached in the last 30 days25 pts
Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.
- Auth declared10 pts
Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.
- Tools listed15 pts
Answer tools/list without a credential, or ship a package that starts in a sandbox without one.
- DescriptionRequired15 pts
- Logo10 pts
- Documentation15 pts
- License10 pts