SiLA 2 Bridge
io.github.K-Dense-AIPublished by GitHub account K-Dense-AIv0.1.2Updated Oct 24, 2026
MCP bridge to any SiLA 2 server (lab-automation standard).
Overview
A local MCP bridge that lets an assistant discover, inspect and command lab instruments that implement the SiLA 2 lab-automation standard.
- What you can do
- Discover SiLA 2 servers on the local network and identify the connected instrument, its features, commands and properties with types, units and constraints. Read and subscribe to instrument properties, such as watching a temperature settle over a set duration. Run SiLA commands, including long-running observable ones, then poll status, progress and results. Cancel running commands through SiLA's CancelController, or reconnect after a power cycle. Review the raw command log for debugging and record-keeping.
- When to use it
- Use it when you have lab hardware or middleware that speaks SiLA 2 — liquid handlers, incubators, plate readers, robotic arms or balances — and want an assistant to inspect capabilities, read sensors or run and monitor commands. A built-in simulator lets you try it without hardware.
- Requirements
- Runs locally as a Python package (uvx labmcp-sila2) over stdio. Needs the instrument address via LABMCP_ADDRESS or a discovery name, and network access to the device. TLS is the default: supply the server's CA certificate as root_cert, or insecure=true for test servers; mutual TLS needs client_cert and client_key. Optional LABMCP_LIMITS, LABMCP_READ_ONLY and LABMCP_SIMULATE.
Installation
In SourceWeft
- Open SiLA 2 Bridge in the dashboard and add it to a workspace.
- Enable the server for the chats that should use its tools.
Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.
Other MCP clients
Follow the launch instructions in the repository.
README
SiLA 2 Bridge — MCP Server
Let an AI agent work with any SiLA 2 server: liquid handlers, incubators, plate readers, robotic arms, balances or scheduling middleware that implement the open SiLA 2 lab-automation standard. The bridge reads the server's own Feature Definitions (FDL), so it knows every command, property, parameter type, unit and constraint. It validates parameters against the FDL before sending, runs and tracks long-running (observable) commands, and cancels them through SiLA's CancelController.
Try it without hardware
--simulate starts a real SiLA 2 server in-process, built with the sila2 library. It runs on 127.0.0.1 on a free port, unencrypted, with discovery off. It implements a simulated thermoblock feature (org.labmcp/simulation/TemperatureController/v1) and the official CancelController feature:
- the observable
CurrentTemperatureproperty, plusTargetTemperature,RampRateandDeviceState ControlTemperature, an observable command with progress, intermediate responses and aDeviceBusydefined errorRunProgram, taking a list of{TargetTemperature, HoldTime}structuresSetRampRate, constrained to 0 < rate ≤ 10 K/sSwitchOff
The whole bridge runs through the real gRPC and FDL path.
Connect your SiLA server
- Find it. Use the
discover_serverstool (mDNS_sila._tcp), or run the server with its address and port shown. SiLA has no default port, but 50052 is common. - TLS. SiLA 2 servers use TLS by default, and most generate a self-signed certificate at startup. Pass that certificate's CA as
--option root_cert=ca.pem: many servers write it to a file or publish it in their discovery record. Servers started in insecure test mode need--option insecure=true. For mutual TLS, add--option client_cert=… --option client_key=…. - Test the connection:
Add to your MCP client
Claude Code
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
--read-only lets the agent browse features, read and subscribe to properties, and check command status, but not call commands. cancel_command stays available. To restrict which commands may run, use --option command_allowlist=Feature.Command,Feature.*. Entries can also be separated by ; or spaces, which is handy inside LABMCP_OPTIONS=command_allowlist=A.B;C.*.
Tools
Safety limits
Override at launch, e.g. --limit max_command_wait_s=60. The main guards for commands:
The server always re-validates too, so parameters rejected there come back as SiLA validation errors.
Example prompts
- "What SiLA servers are on the network, and what can the incubator do?"
- "Set the incubator to 37 °C and tell me when it has reached the temperature."
- "Watch the plate reader's chamber temperature for a minute and tell me if it's stable."
- "Run the 'PCR-short' program on the thermocycler, poll its progress every 30 seconds, and report the result."
- "Something's wrong, cancel everything that's running on the liquid handler."
- "Show me the parameters (types, units and allowed ranges) of the robot's MovePlate command."
Notes
- Types as JSON.
list_featuresrenders each SiLA type as a JSON-schema-like dict:Realbecomesnumber,Integerbecomesinteger,ListbecomesarrayandStructurebecomesobject. SiLA units appear asx-unit(the label) andx-unit-si(the conversion to SI base units, SI = value × factor + offset). Other SiLA details usex-sila-*keys. Values are passed as JSON:Binary: base64 stringsDate:YYYY-MM-DD[±HH:MM]Time:HH:MM:SS[±HH:MM]Timestamp: ISO 8601, UTC if no offset is givenAny:{"type": "Real", "value": 1.5}, basic types only
- Observable commands return an
execution_idright away.get_command_statusreports the SiLA execution status (waiting,running,finishedSuccessfully,finishedWithError), progress, estimated remaining time and the latest intermediate response.get_command_resultreturns the responses, or the defined/undefined execution error together with the error's description from the FDL. Passwait_stocall_commandfor short runs. Executions are tracked only for this session and are forgotten onreconnect. - Cancellation isn't part of core SiLA. It needs the server to implement
org.silastandard/core.commands/CancelController/v1, andget_server_inforeports whether it does. Some vendors provide their ownStop/Abortcommands instead, whichlist_featuresshows. - SiLA client metadata (e.g. a
LockControllerlock identifier or anAuthorizationServiceaccess token) can be passed withmetadata={"LockController.LockIdentifier": "…"}oncall_command,get_propertyandsubscribe_property. Values are validated against the metadata's FDL type. - Feature Definitions are parsed only after refusing any
DOCTYPE/entity declaration (SiLA FDL never uses one), so a hostile server can't trigger XML entity expansion. Features that thesila2library rejects as invalid are left out oflist_features(the command log records why). - Not checked locally:
SchemaandContentTypeconstraints, and theUnitconstraint, which is informational. The server enforces these. Large binaries (over 2 MB) use SiLA binary transfer, which thesila2library handles. - Library limitation (sila2 ≤ 0.14): a Constrained List used directly as a command parameter or response can't be unpacked. Parameters are affected on servers built with
sila2, which is why the simulator'sRunProgramuses a plain list and checks the 1–10 steps itself. Responses of that shape are affected in this bridge: the server executes the command, but its response can't be decoded. The bridge reports this as "WAS EXECUTED … could not be decoded" so the command is not repeated blindly. Properties of that shape decode fine. Plain (unconstrained) lists are not affected. - Discovery browses mDNS for the requested time and returns what servers advertise (UUID, name, version, address, whether a CA certificate is published) without connecting to them. In
--simulatemode it returns only the simulated server and sends nothing on the network.
Hardware verification
Source: servers/protocols/sila2/README.md at commit 46545ea
Tools
0Version history
2- v0.1.2LatestSep 27, 2026
- v0.1.0Sep 26, 2026
Score
50% of the applicable checks met
How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.
- Reached in the last 30 days25 pts
Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.
- Auth declared10 pts
Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.
- Tools listed15 pts
Answer tools/list without a credential, or ship a package that starts in a sandbox without one.
- DescriptionRequired15 pts
- Logo10 pts
- Documentation15 pts
- License10 pts