Thorlabs Optical Power Meter
io.github.K-Dense-AIPublished by GitHub account K-Dense-AIv0.1.2Updated Oct 24, 2026
MCP server for Thorlabs optical power meters (PM100 family, PM400, PM101, PM5020) over SCPI.
Overview
Controls Thorlabs optical power meters over SCPI, letting an assistant read laser power, log stability and adjust wavelength, averaging and range.
- What you can do
- Read power once, plus sensor temperature and device/sensor identity
- Log a power series over time with mean, stdev, RMS, peak-to-peak stability and drift, optionally saved to a new CSV file
- Set correction wavelength, averaging count and power range (auto or fixed)
- Dark-zero the sensor and reconnect after a power cycle
- Inspect connection details, active safety limits and the raw SCPI command log
- When to use it
- Useful in an optics or photonics lab where a Thorlabs PM100D, PM100A, PM100USB or PM400 meter is on the bench and you want an assistant to take readings, characterise laser warm-up or drift, or measure filter transmission. It can also be tried without hardware using the built-in simulator.
- Requirements
- Runs locally as a Python package (uvx labmcp-thorlabs-pm) over stdio. Needs a Thorlabs meter reachable via VISA/USBTMC, its resource string passed as the address, and on Windows the NI-VISA runtime plus the Thorlabs driver switcher; Linux needs udev permissions for vendor 0x1313, macOS needs libusb. Optional environment variables LABMCP_ADDRESS, LABMCP_LIMITS, LABMCP_READ_ONLY and LABMCP_SIMULATE.
Installation
In SourceWeft
- Open Thorlabs Optical Power Meter in the dashboard and add it to a workspace.
- Enable the server for the chats that should use its tools.
Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.
Other MCP clients
Follow the launch instructions in the repository.
README
Thorlabs Optical Power Meter — MCP Server
Let an AI agent read laser power, log stability and warm-up drift, set the wavelength correction, averaging and range, and dark-zero the sensor on Thorlabs optical power meters through their documented SCPI command set over USB (USBTMC / VISA).
Try it without hardware
The simulator is a PM100D with an S120C photodiode (or S302C thermopile) looking at a 1.234 mW, 632.8 nm HeNe laser. Setting the wrong wavelength on the photodiode gives a proportionally wrong reading, as on the real bench.
Connect your power meter
- Driver. Thorlabs meters enumerate as USB Test & Measurement Class (USBTMC) devices, vendor ID
0x1313.- Windows: the Thorlabs driver (TLPM / Thorlabs VISA) is not visible to PyVISA. Install the free NI-VISA runtime, then switch the meter to the NI-VISA driver with the Thorlabs Driver Switcher (installed with the Thorlabs Optical Power Monitor software), and start the server with
?backend=@ivi(see below). This is the route Thorlabs documents for PyVISA. - Linux: pyvisa-py talks USBTMC directly (installed with this package). Give your user access to the device, e.g.
/etc/udev/rules.d/99-thorlabs-pm.rules: thensudo udevadm control --reload-rulesand re-plug the meter. NI-VISA also works (?backend=@ivi). - macOS: pyvisa-py + libusb (
brew install libusb); NI-VISA is an alternative.
- Windows: the Thorlabs driver (TLPM / Thorlabs VISA) is not visible to PyVISA. Install the free NI-VISA runtime, then switch the meter to the NI-VISA driver with the Thorlabs Driver Switcher (installed with the Thorlabs Optical Power Monitor software), and start the server with
- Find the resource string:
uvx labmcp ports(orpython -m pyvisa info). It looks likeUSB0::0x1313::0x8078::P0012345::INSTR(the product ID depends on the model: PM100D0x8078, PM100USB0x8072). - Test the connection:
For the second input of a PM5020 add
--option channel=2.
Add to your MCP client
Claude Code
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
Add --read-only to allow readings but block wavelength, averaging, range and zero changes. For other clients, generate the snippet with uvx labmcp config thorlabs-pm --address <resource> --client vscode (also cursor, codex, claude-code).
Tools
get_connection_info, get_command_log and reconnect are built into every LabMCP server.
A power meter only measures, so this server has no hazard tools. Your laser is the hazard: wear the right eyewear and never exceed the sensor's rated power or power density.
Safety limits
Override at launch: --limit max_series_duration_s=3600. One call can log at most 3640 s (the tool's timeout minus a margin): longer estimates are refused, and a series that runs slower than estimated stops early and returns what it measured (completed: false). save_path must end in .csv and must not exist yet (an existing file is never overwritten); it is checked before logging starts.
Example prompts
- "Set the meter to 1064 nm and tell me the power after the objective."
- "Log the laser power every 2 s for 10 minutes and report the RMS and peak-to-peak stability. Save the data to ~/data/laser_warmup.csv."
- "I've capped the sensor. Zero it, then I'll remove the cap and you read the power."
- "Measure the transmission of this ND filter: read the power without it, then again after I insert it, and give me the optical density."
- "Is the thermal sensor head still warming up? Read its temperature every minute until it's stable."
Notes
- Wavelength matters. Photodiode responsivity varies by a factor of several across the sensor's range, so a wrong wavelength setting gives a wrong power. The server sends whole nanometres (the PM400/PM101/PM5020 references specify an integer), so 632.8 nm is set as 633 nm. That changes the responsivity by far less than the sensor's calibration uncertainty.
- Units.
MEAS:POW?answers in the meter's configured unit (W or dBm). The driver readsSENS:POW:UNIT?first and always returns watts, so a front-panel unit change can't mislead the agent. - Out of range. The meter answers INFINITY / 9.9E37 when the signal exceeds a manually selected range. The server reports this as an error that suggests auto-ranging.
- Zeroing (
SENS:CORR:COLL:ZERO) runs in the background. The server polls…:ZERO:STAT?, checks the error queue, and returns the zero value (…:ZERO:MAGN?). Zero values are lost when the meter reboots. - Energy (pyroelectric) sensors are recognised but not supported: single-pulse energy measurement needs a trigger/fetch workflow that this server doesn't implement yet.
- Averaging is
SENS:AVER:COUN. One sample takes ~3 ms on the PM100 series and 1 ms on the PM400/PM101/PM5020. The reply timeout scales with the averaging count. - PM101 and PM5020: Thorlabs' command references for these list exactly the commands used here. The PM5020 adds a channel suffix (
SENS2,MEAS2,SYST:SENS2:IDN?), selected with--option channel=2. Neither has been tested yet, and PM5020 LAN/serial connections have not been tried. The PM100D's Windows TLPM DLL driver is not used; this server speaks SCPI only. - The simulator's error replies for out-of-range values (
-222,"Data out of range") use the standard SCPI code. The Thorlabs documents only list-113,"Undefined header"explicitly.
Hardware verification
Source: servers/physics/thorlabs-power-meter/README.md at commit 46545ea
Tools
0Version history
2- v0.1.2LatestSep 27, 2026
- v0.1.0Sep 26, 2026
Score
50% of the applicable checks met
How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.
- Reached in the last 30 days25 pts
Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.
- Auth declared10 pts
Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.
- Tools listed15 pts
Answer tools/list without a credential, or ship a package that starts in a sandbox without one.
- DescriptionRequired15 pts
- Logo10 pts
- Documentation15 pts
- License10 pts