best-cad-mcp

io.github.LokmenoWerPublished by GitHub account LokmenoWerv1.7.2Updated Oct 24, 2026

Windows AutoCAD MCP server for handle-first CAD automation, validation, and drawing exports.

Overview

AI-generated overview

Windows AutoCAD MCP server that lets an assistant scan DWG drawings, plan guarded edits, validate them, and export visual evidence.

What you can do
  • Scan and understand drawings: index entities, build CAD-IR, summaries, semantic objects and graphs, constraints and dimension bindings
  • Draft and edit 2D geometry: lines, polylines, curves, hatches, text, dimensions, leaders, tables, layers, blocks, plus move, copy, rotate, offset, trim, fillet and handle-targeted changes
  • Plan and execute guarded changes: express edits as CADPlans, validate and dry-run them, then execute transactionally with undo and rollback attempts
  • Ground visuals and trace images: clean exports, numeric overlays, pixel/world mapping, VLM finding reconciliation, and image-to-CAD tracing with fidelity checks
  • Produce output: 3D solids, layouts, plotting, and PDF, DXF, DWF…
When to use it
Useful when an assistant must work with real AutoCAD drawings on a Windows workstation: inspecting an existing DWG, making precise handle-targeted edits, or generating mechanical drawings and exports under operator review. It is not suited to unattended changes on valuable production drawings.
Requirements
Local Windows machine with AutoCAD 2020 or newer installed and licensed, running under the same Windows user account as the MCP client. Python 3.11 or newer and the best-cad-mcp package (optional visual extra for raster overlays). CAD_MCP_WORKSPACE_ROOT points at the CAD project; CAD_MCP_TOOL_PROFILE selects lean, core or full.
Before you install
Beta software that modifies drawings: raw command execution, deletion, purge, save, close and plan execution should stay behind explicit approval, and work on copies of valuable files. Rollback is best-effort and cannot guarantee recovery from every AutoCAD or COM failure. Scans, logs, exports and a SQLite database are written under the workspace and process folder, so add them to version control ignores.

Installation

In SourceWeft

  1. Open best-cad-mcp in the dashboard and add it to a workspace.
  2. Enable the server for the chats that should use its tools.

Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.

Other MCP clients

Follow the launch instructions in the repository.

README

best-cad-mcp

[PyPI] [Python] [Platform] [License]

A local, handle-first MCP server for agents that work with real AutoCAD drawings.

Inspect a DWG, reason over structured geometry, plan guarded edits, validate the result, and export visual evidence without hiding agent state inside the drawing.

简体中文 · Live demo · Install · Workflow · Tool profiles · Safety · Limitations

[Real AutoCAD three-view drawing of a flanged bearing housing]

A real AutoCAD model-space export created by a validated, dry-run CADPlan: front and top projections, a sectioned side view, centerlines, dimensions, feature callouts, hatches, and a title block. Download the source DWG or inspect the executed CADPlan.

[!IMPORTANT] best-cad-mcp is beta software. It is designed for controlled local workflows where an operator can review plans and evidence, not unattended changes to valuable production drawings.

Why best-cad-mcp

Most CAD automation stops at drawing primitives. Useful agent workflows also need to know exactly what they are changing, why a target was selected, and whether the result is correct.

Handle-first controlDrawing understandingEvidence before trust
Scan real AutoCAD handles, query exact entities, and edit those handles instead of guessing from labels or pixels.Build CAD-IR, semantic objects and graphs, dimension bindings, constraints, and validation reports in a local workspace.Validate and dry-run CADPlans, execute explicitly, rescan, and compare structured and visual results.

The server runs on the same Windows account as AutoCAD and communicates over MCP stdio. It runs natively on the official MCP Python SDK 2.x, negotiates the 2026-07-28 protocol, and retains legacy client negotiation. AutoCAD remains the source of truth; SQLite stores model-private context, scan results, and review artifacts alongside the workspace. AutoCAD-facing tool calls are intentionally serialized on one event-loop thread to preserve COM apartment safety.

Live AutoCAD demo

Prompt: Create a production-style A3 landscape bolted flange-coupling assembly drawing at true 1:1 size, with a longitudinal half-section, aligned end view, exploded schematic, true dimensions, differentiated hatching, an eight-item BOM, matching item leaders, technical requirements, and a controlled title block.

[Bolted flange-coupling assembly generated in a live AutoCAD session]

This is the result of a live AutoCAD session, not a hand-authored SVG. The MCP client loaded the shipped precise_draw_from_spec prompt, then ran 18 bounded generation phases (162 steps). Its autonomous visual-repair loop used two layout-repair plans (4 steps); three separately recorded, operator-authorized presentation-only release-QA plans added 10 steps. Every plan was validated and dry-run before transactional execution. The final rescan indexed 91 entities; structured verification detected 129 semantic objects, processed 7 true dimension annotations, and checked 134 constraints (127 satisfied, 7 unknown, and none violated). Post-repair geometry validation reported zero issues. The release plot was independently checked as a one-page landscape A3 PDF.

For reproducibility, the checked-in MCP client builds the deterministic CADPlans used for this recorded run. The demo shows live execution of the optimized prompt's guarded workflow, not an unscripted one-shot LLM generation.

DXF · A3 PDF · Exact prompt · CADPlan bundle · Verification report · MCP client

The drawing follows the repository's generic mechanical assembly practice and is marked DEMO - NOT FOR MANUFACTURE; it does not claim formal ISO, GB, ASME, or other standards compliance.

Quick start

Requirements

  • Windows
  • AutoCAD 2020 or newer recommended, installed and licensed
  • AutoCAD and the MCP client running as the same Windows user
  • Python 3.11 or newer
  • An MCP-compatible local client

Install the package

powershell
python -m pip install --upgrade best-cad-mcpcad-mcp-doctor --check-autocad

For rendered overlays and visual-review helpers:

powershell
python -m pip install --upgrade "best-cad-mcp[visual]"cad-mcp-doctor --check-autocad --require-visual-export

Keep AutoCAD open, then configure your MCP client to launch cad-mcp.

Codex

Codex supports both global ~/.codex/config.toml and trusted, project-scoped .codex/config.toml files. This minimal installed-package configuration uses the curated core tool profile:

toml
[mcp_servers.best-cad-mcp]command = "cad-mcp"cwd = 'C:\CAD\your-project'enabled = truestartup_timeout_sec = 30tool_timeout_sec = 120default_tools_approval_mode = "writes"
[mcp_servers.best-cad-mcp.env]CAD_MCP_TOOL_PROFILE = "core"CAD_MCP_WORKSPACE_ROOT = 'C:\CAD\your-project'

Restart Codex after editing the file, then inspect the connected server with /mcp. See the official Codex MCP configuration guide for configuration scopes and current options.

Claude Code and other JSON-configured clients

json
{  "mcpServers": {    "best-cad-mcp": {      "command": "cad-mcp",      "env": {        "CAD_MCP_TOOL_PROFILE": "core",        "CAD_MCP_WORKSPACE_ROOT": "C:\\CAD\\your-project"      }    }  }}

Save this as .mcp.json in the CAD project root and start the client from that project. CAD_MCP_WORKSPACE_ROOT should point to the CAD project being worked on, not to this repository. With an installed package, setting both the process cwd and workspace root to the project keeps runtime files together.

Install from source
powershell
git clone https://github.com/LokmenoWer/best-cad-mcp.gitcd best-cad-mcppython -m venv .venv.\.venv\Scripts\Activate.ps1python -m pip install --upgrade pippython -m pip install -e ".[visual]".\.venv\Scripts\python.exe -m src.doctor --check-autocad

For a source checkout, start python -m src.server from the repository or set the MCP server cwd to the repository. Keep CAD_MCP_WORKSPACE_ROOT pointed at the separate CAD project you want to index.

The guarded workflow

[Preflight, scan, dry-run, execute, and verify workflow]

  1. Preflight — run check_runtime_environment(check_autocad=true) or cad-mcp-doctor --check-autocad; stop when the result reports ok=false.
  2. Scan — run scan_all_entities before reasoning about an existing DWG. Use topology_detail="full" for primitive grounding or cross-entity profiles.
  3. Understand — build CAD-IR, summarize the drawing, query semantics, and confirm important targets with explain_entity.
  4. Plan — express multi-step changes as a CADPlan, then call validate_cad_plan and dry_run_cad_plan.
  5. Execute explicitly — only after authorization and an acceptable dry-run, call execute_cad_plan(..., allow_modify=true, transactional=true).
  6. Verify — rescan, run geometric validation, export a clean view and overlay, and save only when the operator intends to persist the DWG.

For precise edits, prefer handles returned by AutoCAD over names inferred from screenshots. For visual findings, treat grounding as evidence: confirm the candidate entity and its geometry before changing it.

What it can do

AreaRepresentative capabilities
2D draftingLines, polylines, curves, circles, regions, hatches, text, dimensions, leaders, tables, layers, blocks, and attributes
EditingMove, copy, rotate, scale, mirror, offset, trim, extend, fillet, chamfer, arrays, properties, PickFirst current-selection inspection, and handle-targeted changes
Drawing understandingSQLite scan, CAD-IR v2, summaries, semantic objects/graphs, constraints, dimension binding, validation, and repair proposals
Guarded automationCADPlan variables, dependencies, captured handles, preconditions, postconditions, dry-runs, transactional execution, undo, and rollback attempts
Visual groundingClean exports, adaptive numeric overlays, pixel/world mapping, path and polygon grounding, tile crops, and VLM finding reconciliation
Image-to-CADImageDrawingSpec tracing, calibration, fidelity checks, staged execution, and visual comparison against the source image
Mechanical drawingsOrthographic views, sections, hatches, centerlines, dimensions, BOMs, balloons, layouts, and assembly-oriented prompt/skill assets
3D and output3D solids and operations, layouts, plotting, PDF/DXF/DWF/image export, and direct in-result image content

Tool profiles

The shipped client configs and examples recommend core because it keeps tool selection reliable while covering normal guarded workflows. When the profile environment variable is omitted, the Python server falls back to full for backward compatibility.

ProfileToolsIntended use
lean116Smallest dependable surface for common drawing and inspection tasks
core213Recommended default for full guarded CAD workflows
full324Every registered tool, including specialized and legacy operations

Select a profile with CAD_MCP_TOOL_PROFILE=lean|core|full. Fine-grained allow/deny controls are also available through CAD_MCP_TOOLS_INCLUDE and CAD_MCP_TOOLS_EXCLUDE.

From visual understanding to grounded CAD evidence

The hero is not an explanatory mockup. It was drawn in a new AutoCAD document through a 90-step CADPlan, scanned as 81 real entities, validated with zero geometry issues, exported as WMF, and rasterized to the PNG shown above. The source DWG, plan, dry-run, validation output, pixel/world mapping, and VLM review are retained as reviewable artifacts.

A VLM review should return more than a caption. Below are real artifacts from the same snapshot: the clean AutoCAD tile inspected by the model and its actual handle overlay. They are raster crops produced by the mapping tool, not redrawn documentation graphics.

The overlay is registered to the WMF selection-export frame, not to the active viewport. AutoCAD's measured proportional frame margin is preserved while the old generic viewport padding is excluded. In this capture the mapped front-view origin is (734.870, 331.032) px and the cyan centerline intersection observed in the real raster is (735, 331) px: a maximum error of 0.13 px.

The real vlm_review_drawing/v3 result was schema-validated and submitted without pre-claiming handles. Its four regions are authored from the raster and locked to that raster's dimensions and SHA-256; the capture script rejects them if AutoCAD produces a different image. Grounding resolved the central bore to handle 8A, the rounded mounting-slot profile to 115, and the title-block semantic group to 236. The section hatch correctly remained ambiguous because two real hatch candidates had a narrow score margin.

json
{  "central_bore":  {"status": "grounded",  "handles": ["8A"]},  "mounting_slot": {"status": "grounded",  "handles": ["115"]},  "section_hatch": {"status": "ambiguous", "handles": []},  "title_block":   {"status": "grounded",  "handles": ["236"]}}

Inspect the hash-locked visual observation, submitted VLM return, grounded result, pixel/world alignment check, CADPlan dry-run, and zero-issue geometry validation.

Copy a mechanical drawing from one image

The full path separates non-mutating understanding from the one explicitly authorized DWG modification stage, then closes with a rescan and visual diff. This README does not present a generated flow illustration as trace evidence; a real run should retain the source raster, ImageDrawingSpec, validated and dry-run CADPlan, resulting DWG, and final AutoCAD export.

A typical tracing loop is:

  1. call prepare_image_trace(image_path, domain="mechanical");
  2. use prepare_visual_semantic_context and get_trace_source_image to inspect global and tiled source images;
  3. produce ImageDrawingSpec/v1, echoing each observed image's source_ref_template for measured coordinates;
  4. call validate_image_drawing_spec, then submit_image_drawing_spec;
  5. call compile_image_spec_to_cad_plan;
  6. call validate_image_fidelity_contract(spec, cad_plan);
  7. call validate_cad_plan, then dry_run_cad_plan;
  8. only after authorization, call execute_cad_plan(..., allow_modify=true, transactional=true);
  9. rescan, validate, and compare the final AutoCAD export with the source.

Do not execute a trace just because its JSON is valid. Check view count, symmetry, dimensions, centerlines, hole placement, and source/render fidelity first.

Visual grounding in v1.6

Version 1.6 adds drawing-level topology for boundaries assembled across multiple entities, including line-line and supported line-curve intersections plus closed-loop profiles. Use scan_all_entities(topology_detail="full") when primitive relations are required. Grounding now carries real path/polygon geometry, multiple-handle candidates, adaptive overlays, and tile-aware pixel/world contracts.

This improves selection quality on mechanical profiles, but it does not make vision infallible. Important edits should still follow:

text
visual finding -> grounding candidates -> explain_entity -> handle-targeted edit

The default VLM review prompt is vlm_review_drawing/v3. Snapshot schema versions are returned in tool results; overlay schema versions are stored in the referenced sidecars so strict consumers can detect contract changes.

Safety model

  • Read and scan before editing an existing drawing.
  • Keep raw command execution, deletion, purge, audit, save, close, and execute_cad_plan behind explicit client approval.
  • Validate and dry-run plans before modification.
  • Use returned handles and structured geometry for exact targets.
  • Rescan after modifications; do not rely on stale SQLite rows.
  • Keep model-private notes and spatial annotations in .cad_mcp/, not in visible DWG geometry, XData, or hidden layers.
  • Treat saving and closing as separate operator decisions.
  • Treat top/plan model-space views as the strongest grounding case. View twist, custom UCS, 3D geometry, and complex layout viewports can reduce confidence.

Transaction and rollback support reduce risk but cannot guarantee recovery from every AutoCAD or COM failure. Work on copies when the drawing is valuable.

Known limitations

  • View grounding is exact only for plan/top model-space views. An untwisted plan view gives numerically stable world↔pixel mapping. View twist is included and flagged; non-plan and 3D views fall back to a 2D plan-view approximation with transform_confidence=low and explicit warnings; paperspace/layout viewport mapping is not fully supported. Carry returned limitations and confidence forward instead of claiming exact grounding in those cases.
  • Raster overlays need the [visual] extra. Without Pillow/cairosvg the overlay degrades to an SVG fallback with a warning; WMF exports rely on the native Windows GDI+ conversion path.
  • Dimension binding is heuristic. Dimensions are matched to candidate geometry with evidence and confidence; ambiguous or unbound dimensions stay unknown by design and are never reported as falsely satisfied.
  • Semantic detection is deterministic and rule-based. Richer objects (slots, bolt-circle patterns, walls, doors, wires, title blocks, BOM tables) are reported as candidates with confidence, not guaranteed classifications, and no external model runs inside the server.
  • CADPlan executes a fixed operation set. Advanced 3D solids, boolean operations, trim/extend, layout editing, plotting, and save/open are not plan operations; use the direct MCP tools for those.
  • Rollback is best-effort. Transactional execution uses AutoCAD undo marks (StartUndoMark/EndUndoMark + undo); it cannot guarantee recovery from every COM or AutoCAD failure, and a failed plan always reports completed_steps for inspection.
  • Scans are bounded. scan_all_entities honors max_entities and reports truncated when the drawing exceeds the cap; topology_detail="full" is expensive on large drawings, so use summary topology by default.
  • Image tracing depends on the agent-side VLM and calibration. The server prepares, validates, compiles, and enforces fidelity; it never calls a model provider. Without reliable dimension calibration, traced drawings carry a scale warning and must not be claimed as true engineering scale.
  • Windows + AutoCAD COM only. Tool calls are serialized on one COM thread, the server must run on the same Windows account as AutoCAD, and hosted CI cannot exercise live COM paths — live smoke benchmarks run locally via scripts/verify_cad_understanding_workflow.py.

Workspace and data

CAD_MCP_WORKSPACE_ROOT controls <workspace>/.cad_mcp/workspace.db. The default log, visual exports, and image trace assets are written relative to the MCP process cwd as cad_mcp.log, cad_visual_exports/, and cad_image_traces/.

External CAD projects are not ignored automatically. Add these entries to the project's .gitignore when it is a Git repository:

gitignore
.cad_mcp/cad_mcp.logcad_visual_exports/cad_image_traces/

The database helps connect turns and tools, but AutoCAD remains authoritative. If a drawing changes outside the server, scan it again before using stored entities. A warning about a legacy root autocad_data.db means an older database exists; verify migration, then archive it separately.

Troubleshooting

SymptomCheck
Server fails to import after upgradingRun cad-mcp-doctor --json with the same Python environment used by the client. best-cad-mcp 1.7+ requires MCP Python SDK >=2,<3; upgrade the package/environment and restart the client if mcp_sdk_version is blocked.
AutoCAD is open but unavailableRun cad-mcp-doctor --check-autocad; make sure both processes use the same Windows account and privilege level.
Server starts with too many toolsSet CAD_MCP_TOOL_PROFILE=core or lean, then restart the client.
Visual export is unavailableThe [visual] extra provides Pillow for raster overlays. On Windows, AutoCAD WMF uses the native GDI+ fallback; ImageMagick/Wand, Inkscape, or LibreOffice provide alternate paths. Check get_vision_capabilities() and wmf_to_png_available; PDF can also be rasterized externally.
Queries return stale entitiesActivate the intended drawing and rerun scan_all_entities.
MCP server starts in the wrong folderSet server cwd to the source checkout only when developing; set CAD_MCP_WORKSPACE_ROOT to the CAD project.
A plan is rejectedRun validate_cad_plan, inspect the exact failing step, and dry-run again after correcting it.

For machine-readable diagnostics:

powershell
cad-mcp-doctor --json

Development

powershell
git clone https://github.com/LokmenoWer/best-cad-mcp.gitcd best-cad-mcppython -m venv .venv.\.venv\Scripts\Activate.ps1python -m pip install -e ".[dev,visual]"python -m pytest -q -m "not autocad_com"

Release publication validates the version, runs the non-COM suite (reserving the autocad_com marker for local live-CAD checks), verifies native modern and legacy MCP stdio, builds and clean-installs the wheel, checks it with Twine, publishes to PyPI, and then publishes the MCP server metadata. Live AutoCAD preflight and CADPlan checks must be run locally because hosted runners do not have AutoCAD.

Contributions are welcome. Please keep changes scoped, add regression tests for behavior changes, and preserve the scan → plan → validate → verify safety model.

For model comparisons, use the agent loop experiment guide to freeze the drawing, source, skill and prompts and record independently reviewed live runs. The offline ledger keeps pending results unknown and does not treat synthetic grounding tests or deterministic demo plans as model evaluations.

Acknowledgements

The model-private annotation and pointer-style CAD context design was informed by the public Pointer-CAD project and paper. No Pointer-CAD source code is copied into this repository.

License

MIT. See LICENSE.

Source: README.md at commit 9f6e3a9

Tools

0
SourceWeft has not started this package in its sandbox yet, so its tools are not known.

Version history

3
  1. v1.7.2LatestSep 23, 2026
  2. v1.7.1Sep 19, 2026
  3. v1.7.0Sep 16, 2026

Score

50% of the applicable checks met

How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.

  • Reached in the last 30 days25 pts

    Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.

  • Auth declared10 pts

    Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.

  • Tools listed15 pts

    Answer tools/list without a credential, or ship a package that starts in a sandbox without one.

  • DescriptionRequired15 pts
  • Logo10 pts
  • Documentation15 pts
  • License10 pts