
KiCad Tools
io.github.ProductOfAmericaPublished by GitHub account ProductOfAmericav0.21.1Updated Oct 24, 2026
Byte-preserving KiCad automation: 100+ tools for schematics, PCB layout, ERC, DRC, exports
Overview
KiCad MCP server with 109 tools that let an assistant read, edit, check and export real KiCad schematics, PCB layouts and libraries on disk.
- What you can do
- Read schematics: list components, labels, wires, sheets, pins and net connections, and find unconnected pins
- Edit schematics: place, move and remove components, add wires, junctions, labels and power symbols, wire pins to nets
- Read and edit boards: list footprints, traces, nets, zones and layers; place footprints, add traces, vias, zones and net classes; sync the netlist from the schematic
- Check and export: run ERC and DRC, validate placement and hierarchy, autoroute with Freerouting, export PDF, SVG, DXF, Gerber, drill, 3D, BOM, netlist and pick-and-place files
- Manage projects and libraries: scaffold projects, add and reorder hierarchical sheets, annotate, browse and author symbol and…
- When to use it
- Useful when an assistant should make concrete changes to a KiCad electronics design rather than hand-editing s-expression files: adding parts and wiring, syncing a schematic to a board, running ERC/DRC, or producing manufacturing exports. Note the project is in maintenance mode and its own README reports that plain coding agents outperformed it in small tests.
- Requirements
- Runs locally as a Python package (Python 3.11+) via uvx or pip. KiCad 9.x or 10.x is needed only for tools that call KiCad: kicad-cli for ERC, DRC, exports and netlist sync, pcbnew bindings for zone filling and autorouting, and stock libraries for placing stock parts. Autorouting also needs Java 25 or newer. Paths can be given by tool parameter, by environment variables such as KICAD_SCH_PATH, KICAD_PCB_PATH and KICAD_OUTPUT_DIR, or auto-detected from a .kicad_pro in the working directory.
Installation
In SourceWeft
- Open KiCad Tools in the dashboard and add it to a workspace.
- Enable the server for the chats that should use its tools.
Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.
Other MCP clients
Follow the launch instructions in the repository.
README
mcp-server-kicad
Let an AI assistant edit real KiCad projects without corrupting them.
109 MCP tools covering schematic capture, PCB layout, symbol and footprint libraries, ERC and DRC, and manufacturing exports. No screenshots, no copy-paste, no hand-edited s-expressions: the model calls tools, KiCad files change on disk.
[PyPI] [Python] [KiCad] [Tests] [License]
Quick start • What you get • Configuration • Tool reference • Requirements • Contributing
[!IMPORTANT] Maintenance mode. As of October 2026 this project gets security fixes and KiCad compatibility fixes only. No new tools or features are planned. Existing installs keep working. Why
Why maintenance mode
The plugin was built on one idea: KiCad files are large, so an AI assistant should change them through tools instead of editing the text. We tested that idea against plain Claude Code with KiCad installed and no plugin: the same model (Claude Opus 5.5), the same settings and the same tasks, each result judged by KiCad 10 itself (netlist, board, ERC and DRC).
- Six single edits on a public KiCad 10 design (a value change, do-not-populate, a footprint swap, pads assigned to a net, a footprint rotation, a net renamed across sheets), three runs each. Plain Claude Code got all 18 right. With the plugin, 3 of 18 were right.
- A long session of 20 board edits. Both got every edit right, and the plugin's sessions used about 1.8 times as much context.
- Why the plugin failed, from reading every transcript:
- It had no tool for some edits (a pad's net, the do-not-populate flag, swapping one footprint).
- Its instructions told the model never to edit KiCad files directly, so the model stopped and asked instead.
- Its board-sync tool rewrote almost every footprint on the board, so the model undid its own work.
- The premise did not hold in these tests. Plain Claude Code changed a 2 MB board without reading it whole: it searched for the part and edited only the lines it needed.
These were small tests on one design, not a verdict on every board or every model. They were enough to stop adding tools. The test material is not published, because the design it used carries no license.
What to use instead: a coding agent such as Claude Code, with KiCad installed. Ask it to check its changes with kicad-cli (netlist export, ERC, DRC) before it finishes.
Bug reports and fixes for KiCad compatibility are still welcome.
What it looks like
Every tool works on the real file, and a write changes only the bytes you asked
it to. An edit that cannot be done correctly is refused with the file intact.
KiCad itself writes a design file in just two places: the library upgrades, and
autoroute_pcb's routed copy, a new board that leaves yours untouched.
Quick start
Claude Code
Install the plugin. It wires up the server and ships the design skills with it:
Claude Desktop
Download kicad-<version>.mcpb from the latest release and install it
from Settings, then Extensions. Claude Desktop fetches Python and the package
itself; you need KiCad installed, plus Java 25 or newer for autoroute_pcb.
Desktop does not run from your project directory, so fill in the schematic,
board, and export paths it asks for. Leave the kicad-cli field blank unless
KiCad is installed somewhere unusual. The design skills are Claude Code only.
Everything else
Then point your MCP client at the unified server, and name your schematic,
board, and export folder in env by absolute path, so tools find them without
being told on every call:
That single entry registers all 109 tools. A client that starts the server in
your project's folder can leave env out: the server then takes the paths from
the single .kicad_pro there (see How paths resolve).
Prefer to split the tools across five smaller servers? See
Configuration.
What you get
Five tool servers
Run them as one unified server, or separately when you want a smaller tool surface in context.
Six design skills (Claude Code plugin)
Tools alone let a model click every button. The bundled skills teach it which buttons, in what order, and what "done" looks like.
The design skills hand their artifacts to independent reviewer subagents
(agents/) before moving on, so a bad BOM or a bad placement plan
gets caught before it becomes a schematic.
Configuration
Split servers
Five entries instead of one, when you want to load only part of the tool surface:
Five-server MCP config
Give each entry the env block from Everything else, with
KICAD_SYM_LIB or KICAD_FP_LIB for the library servers, unless your client
starts them in the project's folder.
Each is also runnable directly:
How paths resolve
Highest priority wins:
- Tool parameters. Every tool accepts an explicit path.
- Environment variables. They override anything auto-detected.
- Auto-detect. The working directory is scanned for a
.kicad_pro, and the schematic, board, and library paths are derived from it.
Requirements
-
Python 3.11+
-
KiCad 9.x or 10.x, only for the tools that call KiCad:
kicad-cli: ERC, DRC, exports, jobsets,get_version, the library upgrades andupdate_pcb_from_schematicpcbnewPython bindings:fill_zonesandautoroute_pcb(which also needs Java 25 or newer; see The Freerouting download)- KiCad's stock libraries: placing a stock symbol or footprint
Every other tool parses files directly and needs no KiCad.
CI covers Linux (KiCad 9 and 10), macOS and Windows (KiCad 10), and Python 3.11 to 3.14.
The Freerouting download
autoroute_pcb runs Freerouting.
Unless FREEROUTING_JAR names a jar, its first call downloads Freerouting 2.5.0,
freerouting-2.5.0.jar (65 MB, needs Java 25 or newer), from
https://github.com/freerouting/freerouting/releases/download/v2.5.0/freerouting-2.5.0.jar
and caches it as ~/.local/share/mcp-server-kicad/freerouting-2.5.0.jar
(%USERPROFILE%\.local\share\mcp-server-kicad\ on Windows). Its SHA-256 is
checked against the value pinned in this package before the download is saved
and every time the cached copy is used. A download that does not match is not
saved; a cached copy that does not match is not run, and is downloaded again.
Freerouting is run with --gui.enabled=false and
--usage_and_diagnostic_data.disable_analytics=true, the settings its
documentation gives for running headless and for not sending usage data, so it
opens no window and its analytics stay off. When it starts, Freerouting still
asks GitHub for its newest release; it has no setting to turn that off.
To skip the download, set FREEROUTING_JAR to the absolute path of a Freerouting
jar you trust. That jar is used as given, with no hash check. A relative path, or
one that names no file, is ignored and the download goes ahead. Earlier releases
cached an unpinned freerouting.jar in the same folder; it is no longer read and
can be deleted.
Finding your KiCad install
A stock install needs no configuration. kicad-cli is found on PATH, then in
/Applications/KiCad/KiCad.app on macOS, then under Program Files and
AppData on Windows, newest first. The stock libraries and pcbnew's Python
are found relative to it. For an unusual install:
Without kicad-cli, the tools that need it stay listed and fail with a message
naming KICAD_CLI_PATH.
KiCad 10 files
The server's own reads and writes handle KiCad 9 and 10 schematics, boards, symbol libraries and footprints alike, and never change bytes you did not ask to change (see docs/adr-cst-substrate.md). Work handed to KiCad itself only succeeds if your install can load the file, and KiCad 9 cannot load a KiCad 10 board:
fill_zonesandautoroute_pcbrefuse a KiCad 10 board on a KiCad 9pcbnewbefore starting; install KiCad 10 or pointKICAD_PYTHONat one.autoroute_pcbon a KiCad 9 board through KiCad 10'spcbnewworks but warns that the routed copy comes back in KiCad 10 format. It never touches the original board.upgrade_symbol_libandupgrade_footprint_liblet KiCad rewrite your files, by design. Each file is replaced atomically and only if it changed, so an interrupted upgrade leaves none damaged. A backup goes to<name>.bak, overwritten every run.
Windows: Controlled Folder Access
Defender's Controlled Folder Access blocks unrecognised apps from writing under
Documents, where KiCad keeps its data. kicad-cli then crashes at startup
(exit 3221225477) on every call, --version included, and the error looks
like a missing file: error 2: The system cannot find the file specified.
The server works around this: it retries once with KICAD_DOCUMENTS_HOME
pointed at an unprotected local folder and keeps it for the session. Set
KICAD_DOCUMENTS_HOME yourself to pick the folder (this turns the retry off).
It cannot fix your project files. If your project lives under Documents, the write tools fail the same way. Move the project, or allow the tools under Windows Security > Virus & threat protection > Ransomware protection > Allow an app through Controlled folder access.
Tool reference
Schematic (42 tools)
Read
Write
Analysis and export
PCB (34 tools)
Read
Write
Analysis and export
Project (24 tools)
Scaffolding
Sheet management
Hierarchy inspection
Cross-sheet analysis
Annotation, export, utilities
Symbol and footprint libraries (9 tools)
Symbol
Footprint
Debugging
Drive the servers by hand with the MCP Inspector:
Contributing
Issues and pull requests are welcome. See CONTRIBUTING.md for development setup, and docs/adr-cst-substrate.md for the architecture decisions behind the byte-preserving write path.
License
GPL-3.0-or-later. Releases up to and including 0.20.1 were MIT-licensed; see NOTICE.
Source: README.md at commit f5f82e0
Tools
0Version history
3- v0.21.1LatestOct 20, 2026
- v0.21.0Oct 15, 2026
- v0.20.1Sep 16, 2026
Score
50% of the applicable checks met
How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.
- Reached in the last 30 days25 pts
Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.
- Auth declared10 pts
Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.
- Tools listed15 pts
Answer tools/list without a credential, or ship a package that starts in a sandbox without one.
- DescriptionRequired15 pts
- Logo10 pts
- Documentation15 pts
- License10 pts