myio_servers
Configured myIO controllers
List the configured controllers (name, URL) with a live check: firmware version, device name, permission level, reachability. Use the name as the `server` argument of the other tools; without it the first controller is used.
Takes no parameters.
myio_info
myIO controller info
Identify the controller: serial, firmware version, CPU/board, device name, element counts (RQ relays, SQ inputs, PCAQ PCA channels, SHQ Shelly, SENQ universal sensors), the permission level of this account (0 admin, 1 editor, 2 user), uptime, found I2C expanders and storage health. Call this first: the version decides which features exist (3.12.x = Due, only base features; 4.x = GIGA/Opta, all features).
Parametersserver
Search outputs, groups, sensors, inputs and universal sensors by name (accent- and case-insensitive substring, e.g. "nappali"). Returns ids and live state so you can use the right control tool.
Parametersqueryrequiredserver
myio_list_devices
List myIO outputs
List outputs with id, name, live state and level: relays (1..RQ), FET/PWM channels (101..116, only on old hardware), PCA dimmer channels (2001..2000+PCAQ), groups (501..). Shows roles in braces: thermostat / sun-controlled / mixer / shutter-up / shutter-down / joiner / rgb:<group> / group:<group>, thermostat thresholds, running timers and group members. By default only NAMED elements are listed (unnamed ones are counted); set include_unnamed=true to see all. Use the ids with the control tools.
Parameterstypeserverinclude_unnamed
myio_read_sensors
Read myIO sensors
All sensor readings in real units: 1-Wire temperature (ids 1..100, °C), humidity (101..110, %), pulse energy meter (200), SDM630 power/voltage/current per phase (201..209: W, V, A), and on 4.x firmware the universal sensors (usens 0..SENQ: temperature, humidity, dew point, power, energy, CO2 ... from KNX/Modbus/MQTT/Shelly/Script; activator id = 300+id). Invalid/missing sensors read "invalid"; STALE = no fresh value within the failsafe time.
Parameterskindserver
myio_get_status
Raw myIO JSON
Fetch a raw JSON endpoint of the controller. Default sens_out.json (live state of all outputs and sensors, minimal fields). Others: d_sens_out.json (with names), f_sens_out.json (all fields), sens_IO.json (+inputs, 4.3.12+/3.12.7+), output.json, relay.json, pca.json, groups.json, prot.json, joiner.json, sensor.json, info.json, usensor.json / shelly.json / link.json / sysdiag.json / flowtrace.json / prog.json / ai.json / alarm.json (4.x, editor level). Keys the account has no permission for are simply absent. Values: temp ×100, hum ×10, thresholds ×10, PCA level 0..255.
Parametersserverendpoint
myio_output
Switch or dim any output
One tool for every output type, by id: relay (1..RQ), FET (101..116), group (501..), PCA dimmer (2001..). action: on | off | toggle | level (level needs `level` 0..255 or `percent` 0..100; PCA/FET only). ON on a dimmer = its configured MAX, OFF = MIN. Reads the state back.
Parametersidrequiredlevelactionrequiredserverpercent
Turn ON a relay output. id = relay id 1..RQ (see myio_info / myio_list_devices). The reply shows the state read back from the controller.
Parametersidrequiredserver
Turn OFF a relay output. id = relay id 1..RQ (see myio_info / myio_list_devices). The reply shows the state read back from the controller.
Parametersidrequiredserver
myio_relay_toggle
Relay toggle
Toggle (invert) a relay output. id = relay id 1..RQ (see myio_info / myio_list_devices). The reply shows the state read back from the controller.
Parametersidrequiredserver
Turn ON a PCA channel (dimmer / universal output). id = 2001..2000+PCAQ (a 1-based channel number is also accepted). ON = the channel's configured MAX level, OFF = its MIN level.
Parametersidrequiredserver
Turn OFF a PCA channel (dimmer / universal output). id = 2001..2000+PCAQ (a 1-based channel number is also accepted). ON = the channel's configured MAX level, OFF = its MIN level.
Parametersidrequiredserver
myio_pca_toggle
PCA toggle
Toggle a PCA channel (dimmer / universal output). id = 2001..2000+PCAQ (a 1-based channel number is also accepted). ON = the channel's configured MAX level, OFF = its MIN level.
Parametersidrequiredserver
Set a PCA channel to an exact level. Give either level (raw 0..255, what the controller stores and shows) or percent (0..100, converted to 0..255). If the channel has an auto-off timer, setting it above MIN (re)starts the timer. id = 2001..2000+PCAQ.
Parametersidrequiredlevelserverpercent
Turn ON a FET/PWM output (legacy hardware only; ids 101..116 - absent on most GIGA/Opta controllers, see myio_list_devices).
Parametersidrequiredserver
Turn OFF a FET/PWM output (legacy hardware only; ids 101..116 - absent on most GIGA/Opta controllers, see myio_list_devices).
Parametersidrequiredserver
myio_pwm_toggle
PWM toggle
Toggle a FET/PWM output (legacy hardware only; ids 101..116 - absent on most GIGA/Opta controllers, see myio_list_devices).
Parametersidrequiredserver
Set a FET/PWM output level: level (raw 0..255) or percent (0..100). Legacy hardware only (ids 101..116).
Parametersidrequiredlevelserverpercent
Turn ON all members of a group of outputs. id = 501..520 (1..20 also accepted). Group commands need EDITOR level on most firmware (a plain user cannot switch groups even with member permissions).
Parametersidrequiredserver
Turn OFF all members of a group of outputs. id = 501..520 (1..20 also accepted). Group commands need EDITOR level on most firmware (a plain user cannot switch groups even with member permissions).
Parametersidrequiredserver
myio_group_toggle
Group toggle
Smart-toggle a group of outputs. id = 501..520 (1..20 also accepted). Group commands need EDITOR level on most firmware (a plain user cannot switch groups even with member permissions). Mixed state: pullUP=1 turns ALL ON, pullUP=0 turns ALL OFF.
Parametersidrequiredserver
myio_send_command
Raw myIO command
Send raw command(s) to the controller, chained with &, e.g. "r_ON=16&r_OFF=5&PCA*2001=128" (PCA level is RAW 0..255). Covers everything in the API reference: thresholds min_temp_ON*<id>=<x10>, names r_descr*<id>=<text>, timers r_timer*<id>=<s>, scene load lo_all=<slot>, button simulation s_hit=<id>, usens*<id>=<x10> etc. Toggle-type config commands (relaysInvert=<id>, PCA_PWM=<id>...) INVERT the flag - read the current value first. Body limit 1024 bytes. The reply lists which outputs changed state.
Parametersservercommandsrequired
myio_inputs
Physical inputs
State of the physical inputs (wall buttons / switches): id (1..SQ), name, pressed/closed now, enabled, NC. Polled state, not events - a short press can be missed. Needs 4.3.12+ or Due 3.12.7+; inputs the account has no permission for are absent.
Parametersserveronly_active
myio_press_button
Simulate a button
Simulate a wall button on input id (1..SQ): kind hit = short press (default), press = long press, release = release after a long press. The controller runs the actions bound to that input (switch/dim/group/scene), exactly like the physical button. The reply lists the outputs that changed.
Parametersidrequiredkindserver
myio_thermostats
Thermostats
Outputs controlled by a sensor: thermostat zones (relay or PCA switched by a temperature sensor: target = middle of the ON/OFF thresholds, band = their distance, mode heat if ON<OFF else cool, current temperature, heating/idle), humidity-controlled outputs, sun-controlled outputs (sunrise/sunset) and analog mixers. Use the ids with myio_set_thermostat.
Parametersserver
myio_set_thermostat
Set thermostat
Change a thermostat zone: target temperature (°C, keeps the band), band / hysteresis (°C 0.1..10, keeps the middle), or the raw ON/OFF thresholds (°C). Optionally bind the sensor: sensor = 1..100 (1-Wire id), 301.. (universal sensor 300+id), 0 = unbind (editor level). Heating = ON below OFF, cooling = ON above OFF. The controller switches the output itself; the reply reads the zone back.
Parametersidrequiredonoffbandsensorservertarget
myio_shutters
Shutters / covers
Shutters, blinds, gates and other UP/DOWN pairs defined as protection pairs on the controller (the two outputs can never be on together): index, name, up and down relay ids, state opening / closing / stopped. Use myio_shutter to move them.
Parametersserver
myio_shutter
Move a shutter
Move a shutter / cover: action open (down off, up on), close (up off, down on) or stop (both off). Identify it by index (from myio_shutters) or by the id of its up relay. The controller enforces the mutual exclusion; the motor runs until its end switch or until you stop it.
Parametersindexup_idactionrequiredserver
RGB lights = groups whose name starts with "RGB", with R/G/B channels (PCA or FET outputs whose names start with R, G, B). Shows on/off, colour (max-normalised 0..255) and brightness (0..255, the highest channel level).
Parametersserver
myio_set_rgb
Set RGB light
Control an RGB light (group id from myio_rgb): on/off, colour r,g,b (0..255 each; the brightness is kept unless given), brightness 0..255 (keeps the colour). ON without colour restores the last colour (white at first). The channel levels are written directly (PCA*<id>=<level>) and read back.
Parametersbgridrequiredonserverbrightness
myio_usensors
Universal sensors
4.x: the universal sensor slots (0..SENQ): name, type (temperature, humidity, dew point, power, energy, CO2 ...), value, ok / STALE / no value, failsafe time, enabled. Sources: KNX, Modbus, MQTT, Shelly, Script, external HTTP (usens*<id>=). Activator id for thermostats = 300+id. Needs editor level.
Parametersserverinclude_disabled
myio_set_usens
Write a universal sensor
4.x: push a value into a universal sensor slot (id 0..SENQ) from outside, e.g. a temperature from another system: value in real units (21.5 °C -> stored as 215). Thermostats, Flow, MQTT and logs see it like any sensor. The slot must be enabled; the reply reads it back.
Parametersidrequiredvaluerequiredserver
myio_config_vars
Raw settings variables
The raw settings block of the controller (the JS variables behind the Setup page: energy manager, SDM, dew point, sensor tables, every array). Give `names` to read specific variables, or `prefix` to list those starting with it; without arguments the variable names are listed. Editor/admin level.
Parametersnamesprefixserver
myio_globals
Controller settings
Global settings: device name, controller clock, time zone (+ automatic EU daylight saving time on/off and whether summer time is in force, 3.12.35 / 4.18.9+), location (for sunrise/sunset), today's sunrise/sunset, button timing (hit/press limits), protection cooldown (4.x), sensor polling periods, pulse meter unit, current/boot scene slot, loggers. Editor/admin level.
Parametersserver
myio_set_globals
Change controller settings
Change global settings: name, time_zone (hours from UTC; with automatic DST on it is the STANDARD/winter offset, e.g. 1 for Central Europe - changing it moves the clock at once on 3.12.35 / 4.18.9+), auto_dst (true/false: automatic EU daylight saving time, 3.12.35 / 4.18.9+, on by default; stored at once, no save needed), latitude/longitude, hit_time_limit / press_time_limit (ms), prot_cooldown (s, 4.x), temp_timer / hum_timer / mixer_timer (sensor polling s), impulse_per_unit, consumption_unit, sync_time=true (NTP sync now). Only the given fields change. Editor/admin level.
Parametersnameserverauto_dstlatitudehum_timerlongitudesync_timetime_zonetemp_timermixer_timerprot_cooldownhit_time_limit+3 more
myio_rename
Rename an element
Set the name (description) of an element. kind: relay (id 1..RQ), pca (2001.. or channel 1..), fet (101..), group (501.. or 1..), input (1..SQ), thermo (1-Wire sensor id 1..100), humidity (channel index 0..), usens (4.x, id 0..SENQ), shelly (4.x), scene (slot 0..). Empty name clears it. Editor level; accents are fine.
Parametersidrequiredkindrequirednamerequiredserver
myio_output_config
Output configuration
Configuration of outputs (relay, FET, PCA): auto-off timer, turn-on delay, inverted wiring, alarm flag, justOn (a button can only switch it on), PCA min/max level, fade speed, PWM (dimmer) vs switch mode, mixer mode, sensor binding and thresholds. Give id for one output, type for one kind, or nothing for all named ones. Editor/admin level.
Parametersidtypeserverinclude_unnamed
myio_set_output_config
Change output configuration
Change an output's configuration (relay 1..RQ, FET 101.., PCA 2001..): timer_s (auto-off, 0 = off), delay_s (turn-on delay), invert, alarm, just_on, and for PCA/FET: min / max level (0..255), fade_speed, pwm (dimmer mode), mixer. Flags are set to the given value (the controller's toggle commands are only sent when the value differs). Editor level.
Parametersidrequiredmaxminpwmalarmmixerinvertserverdelay_sjust_ontimer_sfade_speed
myio_input_config
Input configuration
What the physical inputs (wall buttons) do: enabled, NC contact, hit-block, and the targets of hit (short press), press (long press) and release in the unified id space (relay 1.., FET 101.., group 501.., scene 1000+slot, PCA 2001.., LED strip 3100+). Give id for one input; otherwise the named / bound ones. Editor/admin level.
Parametersidserverinclude_unused
myio_set_input_config
Change input configuration
Change a physical input (1..SQ): enabled, nc (normally closed), hit_block, and the action targets hit / press / release as element ids (0 = none; relay 1.., FET 101.., group 501.., load scene 1000+slot, PCA 2001.., LED strip 3100+). Flags are set to the given value. Editor level.
Parametersidrequirednchitpressserverenabledreleasehit_block
myio_structures
Protection pairs, joiners, groups
The structural configuration: protection pairs (two outputs never on together = shutters; index, UP, DOWN, priority), joiner pairs (master switches the slave too; justOn), groups (id 501.., members in the unified id space, pullUp = mixed state toggles to ON). Editor/admin level.
Parametersserver
myio_set_protection
Set a protection pair
Define or clear a protection pair (index 0..PQ-1, or omit index: an identical existing pair is reused, otherwise the first free one): up and down = output ids that may never be on together (relay 1.., PCA 2001..); 0/0 clears the pair. priority = the first (UP) element wins when both are requested. A pair makes a shutter for myio_shutters. Editor level.
Parametersuprequireddownrequiredindexserverpriority
myio_set_joiner
Set a joiner pair
Define or clear a joiner pair (index 0..JQ-1, or omit: an identical existing pair is reused, otherwise the first free one): switching master also switches slave (ids in the unified space); 0/0 clears. just_on = the slave only follows switching ON. Editor level.
Parametersindexslaverequiredmasterrequiredserverjust_on
myio_set_group
Set group members
Set the member list of a group (id 501..): members = output ids (relay 1.., FET 101.., PCA 2001.., fade variants 4001.. allowed), at most groupSize (usually 10); an empty list clears the group. pull_up = when members are mixed, toggle turns ALL ON (false: all OFF). The controller refuses a group that would contain itself. Editor level.
Parametersidrequirednameservermembersrequiredpull_up
myio_scenes
Scenes (configuration slots)
Scene slots: a slot stores a complete configuration snapshot (outputs, groups, protection, inputs, globals ...) that can be loaded by a timer, a button (target 1000+slot) or myio_scene. Shows the slot list with names, the current and the boot slot. Editor/admin level.
Parametersserver
Scene slots: load (apply slot - this changes outputs and settings), save (store the CURRENT configuration into slot, overwriting it), new (create the next free slot), delete (slot 0 and the boot slot cannot be deleted), set_boot (slot loaded at power-up), rename. Editor level; save/delete are destructive.
Parametersnameslotactionrequiredserver
Scheduled actions from timer.csv: time (or sunrise/sunset with ± offset), optional month/day, weekday filter (empty = every day), event (relay/FET/group/PCA ON/OFF, load scene, SG-Ready mode) and target. Editor/admin level.
Parametersserver
myio_set_timer
Create or change a timer
Create (omit id; an identical existing timer is not duplicated) or change (id) a timer. Time: hour 0..23 + minute 0..59, or sunrise / sunset = "after" | "before" with hour/minute as the offset (max 4 h). Optional month (1..12) and day (1..31) for a one-day timer. days: weekday names ["Mon","Fri"] (omit = every day). event: code or name - 1 load scene (all), 2 relay ON, 3 relay OFF, 4 FET ON, 5 FET OFF, 6 group ON, 7 group OFF, 15 PCA ON, 16 PCA OFF, 8..14/17 load scene parts, 18 SG-Ready mode. param: the target id (relay/FET/group/PCA id, scene slot, SG mode 1..4). Editor level.
Parametersiddaydayshoureventrequiredmonthparamrequiredminuteserversunsetsunrise
myio_delete_timer
Delete a timer
Delete the timer with the given id (from myio_timers). Editor level.
Parametersidrequiredserver
The user accounts of the controller: slot, login name, level (admin / editor / user). Slot 0 is the admin. Editor/admin level.
Parametersserver
User accounts (ADMIN level): action new (next free slot), delete (slot, not 0), rename (slot + name), set_password (slot + password; the login name of the slot is used), set_rights (slot + rights admin|editor|user; not slot 0). Changing the account the server itself uses will break the connection.
Parametersnameslotactionrequiredrightsserverpassword
myio_permissions
User element permissions
Element permissions of a user slot (4.x): read / write per relay (and FET), hit / press per input - the lists of element ids the user may see / switch. On Due 3.x the map cannot be read (only set with fill/clear and explicit toggles). Admin level reads it too.
Parametersslotrequiredserver
myio_set_permissions
Change user element permissions
Change the element permissions of a user slot (ADMIN). fill = grant everything, clear = revoke everything. Then per list the ids to GRANT or REVOKE: relay_read, relay_write, pca_read, pca_write, fet_read, fet_write (output ids), input_hit, input_press (input ids). On 4.x the current map is read first and only differences are sent; on Due 3.x the firmware toggles are sent as given (each id flips its bit).
Parametersfillslotrequiredcleargrantrevokeserver
The Flow rule engine (GIGA/Opta 4.4+): every rule as WHEN trigger / AND conditions / THEN actions in plain words with element names, its live state (enabled, running, last fired), the 32 global variables with live values and the webhook targets. id = one rule (with its raw JSON for editing); raw=true returns the whole flows.jsn (the format myio_flow_save takes). Editor/admin level.
Parametersidrawserver
myio_flow_save
Create / change / delete Flow rules
Edit flows.jsn and reload the engine (no restart). Give ONE of: flow (a whole rule object; replaces the rule with the same id or adds it), delete (flow id), variable {id,name,init} / delete_variable, hook {id,name,met,url,body,err,gap} / delete_hook, or file (the complete flows.jsn). The rule is validated against the controller's card rules first; nothing is written on error. dry_run=true only validates. Card format (keys are short): WHEN t=sens{src:thermo|hum|usens, ch|id, op:gt|lt, val x10, hyst x10} | scmp | out{id, dir 0 off/1 on/2 any} | time{min, days} | sun{ev:rise|set, off} | var{id, op, val} | boot; AND t=sens | scmp | out{id, on 0|1} | twin{from, to, days} | var; THEN t=rel|grp{id, act 0 off/1 on/2 toggle} | pca|fet{id, val 0..255} | delay{s|m} | var{id, op:set|inc|dec, val} | log{val} | msg | http{id: webhook slot, val}. days = bitmask bit0=Mon..bit6=Sun (127 = every day); minutes of day for time/twin; temperatures x10 (21.5 °C = 215). Full reference: myio_reference topic=flow. Editor/admin level.
Parametersfileflowhookdeleteserverdry_runvariabledelete_hookdelete_variable
myio_flow
Run / switch a Flow rule
Runtime control of the Flow engine (does NOT change flows.jsn): enable / disable a rule until the next reload or restart (use myio_flow_save en=0|1 to make it permanent), fire = run its THEN chain now (WHEN/AND skipped), set_var = set global variable id (1..32) to value (variable triggers are evaluated). The answer shows the outputs that changed and the trace. Editor/admin level.
Parametersidrequiredvalueactionrequiredserver
myio_flow_trace
Flow trace
What the Flow engine did recently (newest first): fired, AND failed, actions, delays, errors, webhook results, with seconds ago. since = the tseq of a previous call to get only newer entries (incremental). Also the engine budget statistics. Editor/admin level.
Parameterslimitsinceserver
myio_webhook_test
Test a webhook
Fire webhook slot 1..8 (as loaded from flows.jsn hooks[]) once, without the gap brake, and report the HTTP result from the trace. GIGA/Opta 4.4.1+. Editor/admin level.
Parametersslotrequiredserver
myio_scripts
Scripts (myIO Script programs)
The program engine (GIGA/Opta 4.10+): every slot (prog/N.txt, 16 on GIGA, 8 on Opta) with name, state (off / RUNNING / ERROR with line:col and message), cycle time, runs, timing, local variables and arrays, plus the 32 global variables and (trace=true) the recent trace. Editor/admin level.
Parametersidtraceserver
myio_script_get
Read a script
The source code of script slot N (prog/N.txt) and its state. Language reference: myio_reference topic=script. Editor/admin level.
Parametersidrequiredserver
myio_script_save
Write a script
Write the source of script slot N (prog/N.txt) and recompile it on the controller; the answer is the compile result (error with line:col and the source line) and the new state. enabled=true|false rewrites the #enabled directive. The file is the truth (#name, #every 1s, #enabled, #onboot header). Max size: 8 KB on GIGA, 4 KB on Opta. Language reference: myio_reference topic=script. Editor/admin level.
Parametersidrequiredserversourcerequiredenabled
myio_script
Run / switch / delete a script
Script slot actions: reload (recompile prog/N.txt; id 0 = all), run (run once now, even if disabled), enable / disable (RAM only until reload/restart; persist=true also rewrites #enabled in the file), delete (removes prog/N.txt, needs MYIO_WRITE=config). Editor/admin level.
Parametersidrequiredactionrequiredserverpersist
myio_reference
myIO language / API reference
The controller documentation bundled with this server (Hungarian, the canonical API_REFERENCE.md): topic=script = the complete myIO Script language (directives, syntax, built-in functions, error codes, examples); topic=flow = the Flow engine and the flows.jsn card format; topic=api with query = the API sections whose heading contains the query (without query: the table of contents).
Parametersquerytopicrequired
myio_sysdiag
System diagnostics
Health snapshot of the controller: uptime and last reset cause (watchdog?), main-loop speed and the longest stall, free RAM and its minimum, M4 button core, LAN link / WiFi, every network socket with its peer, outgoing HTTP slots, storage space, login brake counters. Due 3.12 gives a shorter set. raw=true = the JSON. Editor/admin level.
Parametersrawserver
myio_metrics
Prometheus metrics
The /metrics text (Prometheus format: uptime, loop rate, RAM, M4, link, WiFi RSSI, sockets, webhook counters, storage, usens values, 1-Wire temperatures). filter = only lines containing this text. GIGA/Opta 4.4.1+.
Parametersfilterserver
Which daily CSV logs exist: event log (ev_log/), consumption (c_log/), SDM meter (sdm_log/), per-sensor temperature (t_log_N/), humidity (h_log_N/), universal sensor (u_log_N/). Without kind: the log folders on each volume and the newest event-log days. kind (+channel for temperature/humidity/usens) = every file of that log with size and date. Read one with myio_log. Editor/admin level.
Parameterskindserverchannel
Read one day of a log (default: today's event log) with filters: level (error | info | debug - 4.x event log lines start with E/I/D), contains (text), since / until (HH:MM), tail (last N matching lines, default 150; 0 = all). date = YYYY-MM-DD, YYMMDD, today or yesterday; or give path (e.g. /ev_log/e_261025.csv). vol: q | s (default: the controller's own lookup, internal flash first). Editor/admin level.
Parametersvoldatekindpathtaillevelsinceuntilserverchannelcontains
List a folder on the controller's storage: name, size, date; folders first; free/total space. vol q = internal flash (GIGA/Opta), s = SD card (Due: only s). Editor/admin level.
Parametersdirvolserver
myio_file_read
Read a file
Download a file from the controller. Text files come back as text (truncated at max_bytes, default 64 KB); binary files as size + hex preview, or base64=true for the content (max 512 KB). Editor/admin level.
Parametersvolpathrequiredbase64servermax_bytes
myio_file_write
Write a file
Upload a file to the controller (creates or overwrites; the write is not atomic). content = text (UTF-8) or base64 = binary. make_dirs=true creates missing parent folders. System files (network, passwords, licence, cloud keys, web UI folders htm/ js/, slot folders) need MYIO_WRITE=admin. For flows.jsn / prog/N.txt prefer myio_flow_save / myio_script_save (validated + reloaded). Editor/admin level.
Parametersvolpathrequiredbase64servercontentmake_dirs
myio_file_op
Delete / rename / copy files
File operations: delete (a file or an EMPTY folder), mkdir, rename (move within the volume: path -> to), copy (path -> to, folders recursively; on GIGA/Opta also between volumes with to_vol). The controller refuses to delete slot_0, the boot scene slot or a slot a button/timer refers to. System files need MYIO_WRITE=admin. Editor/admin level.
Parametersoprequiredtovolpathrequiredserverto_vol
myio_fm_sync
Internal flash -> SD mirror
The QSPI -> SD card configuration mirror (GIGA/Opta 4.4.3+): op status (default), config (mirror the configuration now), web (configuration + web UI folders), adopt (adopt a foreign card: write mirror.tag, then mirror). Needs an SD card and MYIO_WRITE=admin for the actions.
Parametersopserver
myio_shelly
Shelly devices
Shelly integration (GIGA/Opta 4.1+): every registered Shelly with IP, model, online state, relay state, and its bindings (which myIO output a channel follows, which myIO button an input drives, which universal sensor a metric feeds). scan=true also shows the results of a network scan (start one with myio_shelly_set action=scan). Editor/admin level.
Parametersscanserver
myio_shelly_set
Configure Shelly
Change the Shelly integration; every change is saved (sh_save). action: enable (enabled=true|false), add (ip), add_found (index from the scan), scan (start=true|false), delete / probe / push (device), disable (device, disabled), rename (device, name), poll (device, ms 500..60000), auth (device, user, password), bind_output (device, channel, output_id: the Shelly channel follows that myIO output; 0 = unbind), bind_input (device, channel, button 1..SQ, mode 0 button / 1 toggle / 2 hit-only), bind_sensor (device, slot 0..3, metric 1 temp / 2 hum / 3 power / 4 volt / 5 curr / 6 energy / 7 device temp, channel, usens id; usens 0 = unbind). After input / sensor bindings send action=push so the Shelly calls back. Device = slot number from myio_shelly. Editor/admin level.
Parametersipmsmodenameslotuserindexstartusensactionrequiredbuttondevice+7 more
myio_link
myIO Link (controller to controller)
myIO Link (GIGA/Opta 4.2+): the other myIO controllers this one polls, their online state, the output links (a local output mirrors / drives a remote one) and sensor links (a remote sensor feeds a local universal sensor). scan=true shows network scan results. Editor/admin level.
Parametersscanserver
myio_link_set
Configure myIO Link
Change myIO Link; saved with ml_save. action: add (ip), add_found (index), scan (start), delete / probe / refresh_names (server slot 0..), disable (server, disabled), port / poll / rename / auth (server, port | ms | name | user+password), link (index, local_id, server 1.., remote_id: local output follows the remote one), unlink (index), link_disable (index, disabled), sensor_link (index, remote_id, server 1.., local_usens), sensor_link_disable (index, disabled). Editor/admin level.
Parametersipmssrvnameportuserindexstartactionrequiredserverdisabledlocal_id+4 more
MQTT client settings and live state (GIGA/Opta 4.3+, Due 3.12.31+): broker, connection state, topics, retain/QoS, Home Assistant discovery, publish masks, subscribe/command channel, external sensor bindings (topic + JSON key -> universal sensor, 4.5+). Passwords and TLS keys are never shown. Editor/admin level.
Parametersserver
myio_mqtt_set
Configure MQTT
Change the MQTT client. Only the given fields change; on/off fields are desired values (sent only when different). save=true (default) persists and reconnects (MqttSave). Fields: enabled, host, port, user, password, client_id, base_topic, retain, qos 0|1, ha_discovery, economy (4.x), tls (4.x), publish_on_change {buttons, outputs, activators}, periodic {outputs, temperatures, humidity, usens (4.x), sdm} + period_s 5..65000, subscribe, command_channel, command_slot; sensor_binding {slot, topic, key, usens} (4.5+; usens 0 = unbind); rediscover=true refreshes the Home Assistant entities without reconnecting. Editor/admin level.
Parametersqostlshostportsaveuserretainservereconomyenabledpasswordperiod_s+10 more
myIO Cloud remote access (GIGA/Opta 4.4+): enabled, connection state, broker, pairing window, paired phone keys (label, user slot, revoked). Credentials and keys are never shown. Admin level on the controller.
Parametersserver
myio_cloud_set
Manage myIO Cloud
myIO Cloud actions (admin): enable (enabled=true|false), pair (user_slot 1.., label: opens a 5-minute pairing window for one phone - show the QR from the web page), pair_stop, revoke (key, revoked=true|false), delete_key (key). Needs MYIO_WRITE=admin.
Parameterskeylabelactionrequiredserverenabledrevokeduser_slot
myio_sgready
SG-Ready heat pump
SG-Ready heat pump control (GIGA/Opta 4.4.2+, Due 3.12.9+): enabled, current mode (1 inhibit / 2 normal / 3 recommended / 4 forced), K1/K2 contact outputs, utility-lock limit. Editor/admin level.
Parametersserver
myio_sgready_set
Set SG-Ready
Change SG-Ready: mode 1..4 (immediate; mode 1 ends automatically after limit_min), enabled, k1 / k2 (output ids: relay 1.. or PCA 2001..; 0 = none; K1 and K2 must differ), limit_min 1..120. Mode is a state change (MYIO_WRITE=state); the others are configuration. Saved immediately (EEPROM).
Parametersk1k2modeserverenabledlimit_min
myio_alarm
Alarm panel (SIA receiver)
The alarm panel receiver (GIGA/Opta 4.5.8+, SIA DC-09 over TCP/UDP): enabled, listeners, frame counters, troubles (AC, battery, tamper, communication, zone, supervision), per-partition state (disarmed / partial / armed / ALARM) with the last event code, zone and user, and the universal sensor each partition feeds. Monitoring only (no arming). Editor/admin level.
Parametersserver
myio_alarm_set
Configure the alarm receiver
Change the SIA receiver (saved with AlarmSave): enabled, tcp, udp, ack_timestamp (desired values), port 1024..49151 (not 80/843), account (max 32), supervision_min 0..1440, partition_sensor {partition 1.., usens (0 = none)}. simulate = a DC-03 test event like "Nri1/BA01" (burglary alarm partition 1 zone 1) - drives the partition state and its usens; reset_counters=true. TCP on/off takes effect after a restart. Editor/admin level.
Parameterstcpudpportserveraccountenabledsimulateack_timestampreset_counterssupervision_minpartition_sensor
myio_mia
MIA (self-learning heating)
MIA, the self-learning heating layer (GIGA/Opta 4.11+): features (thermal model, window detection, preheating, pause), and per thermostat zone the learned heat/cool rates, dead time, over/undershoot, duty, confidence, window events, preheating plan and result. zone = one relay id. Editor/admin level.
Parameterszoneserver
myio_mia_set
Configure MIA
Change MIA (saved immediately): enabled, features {model, window, preheat, pause} (desired values), window_drop_c 0.1..5, window_min 2..15, window_hold_min 5..240, preheat_max_min 15..240 (4.12+), learn_days 1..6, exclude {relay, excluded} (MIA does not act on that zone), exclude_f3 {relay, excluded} (4.13+), min_on_off {relay, on_min, off_min} (0 = auto, 4.13+), reset_learned (relay id, 0 = all zones). Editor/admin level.
Parametersserverenabledexcludefeaturesexclude_f3learn_daysmin_on_offwindow_minreset_learnedwindow_drop_cpreheat_max_minwindow_hold_min
Addressable LED strips (GIGA/Opta 4.3.4+): enabled, strips per IO pin (LED count, running program), programs (effect, speed, brightness, colours, blend/kill transitions...). prog = one program with the effect list. Event id 3100+100*(IO-1)+program starts/stops a program (buttons, timers, Flow). Editor/admin level.
Parametersprogserver
myio_ledstrip_set
Control / configure LED strips
LED strips: event (id 3100+100*(IO-1)+program: run that program on that IO, the same id again stops it - MYIO_WRITE=state), enabled (desired), program edits (prog 1..32 with fields {fx, speed, brightness, intensity, density, length, palette, direction, color1, color2 (0xRRGGBB number), a, b, blend, blend_fx, blend_dir, kill, kill_fx, kill_dir, off_pause}, name) applied live and saved (ls_save); led_count {io 1..8, count} needs a restart. Editor/admin level.
Parametersnameprogeventfieldsserverenabledled_count
myio_network
Network settings
Network configuration and live state (GIGA/Opta 4.x): host name, LAN (DHCP/static, link), WiFi mode (off / STA / AP), STA and AP settings, live addresses, RSSI, which services run on which interface. Passwords are never shown. Editor/admin level.
Parametersserver
myio_network_set
Change network settings
DANGEROUS: a wrong value can make the controller unreachable (then only USB serial or the service access point helps). Changes: host, wifi_mode 0 off / 1 STA / 2 AP, sta {ssid, password, dhcp}, ap {ssid, password, channel 1..13}, lan {enabled, dhcp, static_primary}. apply=true saves AND applies now (no restart; the connection may drop), apply=false only saves for the next boot. Needs MYIO_WRITE=admin.
Parametersaplanstahostapplyrequiredserverwifi_mode
myio_system
Restart / firmware update
Admin actions: restart (soft reboot, ~1 min offline), ota_upload (file = local path of the firmware package the fleet tool made for THIS controller - GIGA/Opta (4.x): MYIO_UPD.BIN, uploaded to the SD card, or internal flash without a card; Due (3.12+): MYIO_NEW.BIN, SD card only, checked before upload: a raw Arduino build or a package made for another controller is refused), ota_apply (the controller installs the uploaded package and restarts; a GIGA/Opta rolls back by itself if the new image fails, a Due keeps its running firmware if the package is rejected), ota_restore (GIGA/Opta only: go back to the previous image). The answer waits for the controller to come back and reports the running version and the outcome. Needs MYIO_WRITE=admin.
Parametersfileactionrequiredserver
myio_expanders
RS485 expanders
RS485 expander panels on an Opta (4.5+): per address the configured type (Ext16 I/O, Ext-KNX, Ext-DALI, Ext-DMX, Ext-RS485 Modbus), online state, firmware/protocol, last seen, failsafe/standalone rules for losing the master, AUX output modes, Ext16 1-Wire thermometers. addr = one panel (1..). Editor/admin level.
Parametersaddrserver
myio_expander_set
Configure expanders
Expander settings (Opta 4.5+): failsafe {addr, mode 0 hold / 1 all off / 2 preset / 3 standalone, timeout_s 1..250, master, rules_linked, relink_truth, autosync, thermo_stale, stale_period_s} (saved; sync=true pushes the rules to the panel now), capture_preset (addr: the current outputs become the failsafe preset), aux {addr, pin 0=AUX2 1=AUX3, mode 0 0-10V / 1 LED strip}, onewire_rescan=true, onewire_forget (eeprom id of an OFFLINE sensor), forget_panel (addr of an OFFLINE panel). Editor/admin level.
Parametersauxserverfailsafeforget_panelcapture_presetonewire_forgetonewire_rescan
Ext-KNX gateway on an Opta (4.5+): the group-address table of the selected panel (row, name, group address, direction IN/OUT/SENSOR, DPT, local channel, flags, target universal sensor), the KNXnet/IP tunnelling interface for ETS (4.14+) and the KNX devices found/programmed without ETS. Editor/admin level.
Parametersserver
myio_knx_set
Edit the KNX table
Edit the Ext-KNX group-address table (the panel stores it; save=true (default) commits with KnxSave). panel = select another Ext-KNX panel first. rows: [{row 0..47, ga "main/middle/sub" ("" deletes the row), dir 0 none / 1 IN / 2 OUT / 3 SENSOR, dpt 1 bool / 2 percent / 3 float, local 0..15 (panel channel), target usens (SENSOR rows), invert, init_read (desired values), name (max 20, saved at once, 4.15+)}]. tunnel = enable/disable the ETS interface (4.14+), drop_tunnel=true closes the active ETS connection. Editor/admin level.
Parametersrowssavepanelservertunneldrop_tunnel
myio_knx_device
KNX devices (without ETS)
KNX device operations over the Ext-KNX panel (Opta 4.14+): scan (who is on the line, ~2 s), add (address a.l.d to the list), ping / info / delete / rename (index from myio_knx), program (address: writes the individual address into the ONE device whose programming button is pressed - needs MYIO_WRITE=admin). The answer waits for the result.
Parametersnameindexactionrequiredserveraddress
Ext-DALI gateway on an Opta (4.8.6+): panels, the registered endpoints (short address / group / broadcast), the myIO PCA channel each is bound to (dim it with myio_output), last sent and driver-reported level, desired vs driver-read parameters (fade, power-on, failure level, min/max, curve) and group membership. ep = one endpoint. Editor/admin level.
Parametersepserver
myio_dali_set
Configure DALI
DALI registry and driver settings (Opta 4.8.6+; saved automatically). action: bind (ep, pca_id 2001.. or 0), settings (ep, any of fade_time 0..15, fade_rate 0..15, power_on, system_failure, min, max 0..254, curve 0 log / 1 linear; write=true (default) sends them to the driver), groups (ep, group 0..15, member true|false), read (ep: read the driver), identify (ep), add (panel, address 0..63 short / 64..79 group / 80 broadcast), add_all (panel: everything the last scan found), delete (ep), pool (lo, hi PCA ids), auto_bind, scan (panel: find drivers on the bus), abort (panel), commission (panel, mode 0 = re-address ALL / 1 = only unaddressed, start 0..63 - admin), short_address (ep, new 0..63 - admin), reset (ep - admin), panel_config (panel, field 0..6, value). Editor/admin level.
Parametersephilomaxminmodecurvefieldgrouppanelstartvalue+11 more
Ext-DMX gateway on an Opta (4.9+): panels, fixtures (start address, type dimmer/RGB/RGBW/generic, channels) and the myIO PCA channel each DMX channel follows (dim it with myio_output / myio_set_rgb). Editor/admin level.
Parametersserver
myio_dmx_set
Configure DMX
DMX fixtures (Opta 4.9+; saved automatically). action: add (panel, address 1..512, type 0 dimmer / 1 RGB / 2 RGBW / 3 generic), delete (fixture), address (fixture, address), type (fixture, type), channels (fixture, count 1..16 - generic only), bind (fixture, channel 1.., pca_id 2001.. or 0), auto_bind, pool (lo, hi), test (fixture: full on for 1.5 s - state), blackout (panel: all 512 slots to 0 - state), panel_config (panel, field 0..5, value). Editor/admin level.
Parametershilotypecountfieldpanelvalueactionrequiredpca_idserveraddresschannel+1 more
myio_modbus
Modbus RTU master
Ext-RS485 Modbus RTU master on an Opta (4.16+): per panel the bus settings, the poll blocks (slave, function, start register, count, period), the fields decoded from them (type, byte order, scale, target universal sensor) with live values, the writer slots (myIO relay/PCA -> Modbus register), and raw-request / address-scan results. Editor/admin level.
Parameterspanelserver
myio_modbus_set
Configure / query Modbus
Modbus panel table (Opta 4.16+; the panel saves 8 s after the last change, or save=true now). action: block (panel, index 0..7, slave 1..247, func 1..4, start, count 1..125, period_s, enabled), field (panel, index 0..31, block, offset, dtype 1 u16 / 2 i16 / 3 u32 / 4 i32 / 5 f32 / 6 u64 / 7 i64 / 8 f64 / 9 bit / 10 bool, order 0 ABCD / 1 CDAB / 2 BADC / 3 DCBA, bit, scale -9..9, sf_offset (255 none), target usens, enabled, invert), writer (panel, index 0..15, slave, func 5/6/16, reg, dtype, order, source_pca, off, on, period_s, enabled, invert), delete (panel, table 0 block / 1 field / 2 writer, index), bus (panel, baud code 0 9600 / 1 19200 / 2 38400 / 3 57600 / 4 115200, frame 0 8N1 / 1 8E1 / 2 8O1 / 3 8N2, timeout_ms, retries, gap_ms), name (panel, field_index or writer_index or none for the panel, name), preset (panel, preset id e.g. SDM630), reload (panel), clear (panel - admin), raw (panel, slave, func, reg, count: one request, result shown) and scan (panel, from, to, func, reg: which slave addresses answer). Editor/admin level.
Parametersontobitoffregbaudfromfuncnamesaveblockcount+24 more