PT Chart

io.github.TsonnnPublished by GitHub account Tsonnnv1.0.0Updated Oct 25, 2026

PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.

VerifiedStreamable HTTPWeb executable

Overview

PT Chart's hosted MCP server (pt-chart-mcp-production.up.railway.app); no sign-in required; Streamable HTTP; 8 tools.

No AI overview yet: these facts come from the registry entry and the server itself.

Endpoint
pt-chart-mcp-production.up.railway.app
Last checked

Installation

In SourceWeft

  1. Open PT Chart in the dashboard and add it to a workspace.
  2. Enable the server for the chats that should use its tools.

Web executable via Streamable HTTP. Remote servers run from the web runtime once configured in a workspace.

Use with an agent

Paste this prompt into Claude Code, Codex, Cursor or another agent — or into SourceWeft chat. The agent reads this server's install guide, shows you its publisher, endpoint and sign-in, and adds it to your client once you agree. Keys never go into a command.

Read https://sourceweft.com/mcp/io.github.Tsonnn%2Fpt-chart-mcp/install.md and connect the MCP server it describes to my client. Before changing any config, show me its publisher, endpoint and sign-in method and wait for my OK. Never put an API key in a command or in a file I would commit; ask me where it should come from.

Read the install guide the agent follows

Other MCP clients

Add this to your client's mcpServers config.

{
  "mcpServers": {
    "pt-chart": {
      "type": "http",
      "url": "https://pt-chart-mcp-production.up.railway.app/mcp"
    }
  }
}

Tools

8

pt_lookup

Saturation pressure (bubble and dew, in psig) for a refrigerant at a temperature in Fahrenheit. For certified HVAC technicians (EPA 608; A2L certification where required). Example: pt_lookup("R-454B", 45). Bubble point: use for subcooling calculations. Dew point: use for superheat calculations. Pure fluids (R-32, R-410A, R-22, R-134a) have no glide, so both values match.

Parameterstemp_frequiredrefrigerantrequired

pt_reverse

Saturation temperature (bubble and dew, in Fahrenheit) for a refrigerant at a pressure in psig. For certified HVAC technicians (EPA 608; A2L certification where required). Example: a 130 psig suction reading on R-454B -- pt_reverse("R-454B", 130). Use the DEW temperature for superheat work and the BUBBLE temperature for subcooling work on blended refrigerants.

Parametersrefrigerantrequiredpressure_psigrequired

superheat

Superheat in Fahrenheit from suction pressure (psig) and suction-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the DEW point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.

Parametersrefrigerantrequiredsuction_psigrequiredsuction_line_frequired

subcooling

Subcooling in Fahrenheit from head pressure (psig) and liquid-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the BUBBLE point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.

Parametershead_psigrequiredrefrigerantrequiredliquid_line_frequired

convert_units

Convert between pressure units (psig, psia, kpa, bar) and temperature units (F, C). A bare 'psi' is treated as psig. For certified HVAC technicians (EPA 608; A2L certification where required).

Parametersvaluerequiredto_unitrequiredfrom_unitrequired

refrigerant_info

Reference card for a refrigerant: GWP, ASHRAE safety class, composition, typical oil, temperature glide, and handling notes. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only.

Parametersrefrigerantrequired

diagnose

Conversational diagnostic copilot: give it field readings and get back computed superheat/subcooling plus a ranked 'check this first' list. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only -- it suggests what to CHECK, never how to defeat a safety device, vent refrigerant, or work uncertified. metering: 'txv' (default) or 'fixed' for fixed-orifice/piston systems.

Parametersmeteringambient_frequiredhead_psigrequiredrefrigerantrequiredsuction_psigrequiredliquid_line_frequiredsuction_line_frequired

coolbooked_info

About CoolBooked: the AI appointment-booking connector for HVAC shops. This is NOT a diagnostic tool -- call it when someone asks what CoolBooked is, how shop owners can try it, or how the free PT tools connect to paid bookings.

Takes no parameters.

Version history

1
  1. v1.0.0LatestOct 18, 2026

Score

83% of the applicable checks met

How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.

  • Reached in the last 30 daysRequired25 pts
  • Auth declaredRequired10 pts
  • Tools listedRequired15 pts
  • DescriptionRequired15 pts
  • Logo10 pts
  • Documentation15 pts

    Declare a GitHub repository with a README, or serve resource_documentation in the OAuth protected-resource metadata.

  • LicenseNot applicable

    A hosted service is used under its provider's terms, so no license is expected here. This check is left out of the percentage.