Brick Bacnet Mcp

io.github.Yveshby27Published by GitHub account Yveshby27v0.1.0a2Updated Oct 24, 2026

Read-only BACnet/IP MCP gateway with Brick + Haystack semantic tagging at ingest

The publisher's own server: brick.blue

Overview

AI-generated overview

Read-only BACnet/IP gateway that exposes building automation points to an assistant, tagged with Brick and Haystack semantics at ingest.

What you can do
  • Discover BACnet/IP devices on the local broadcast domain and list them
  • Enumerate objects per device and read present-value, units and description
  • Tag objects with Brick classes and Haystack tag sets using editable YAML rules
  • Query the tagged topology, for example filtering for all air-handling units
When to use it
Useful for building-automation or facilities work where an assistant should inspect BACnet/IP point data from mixed-vendor buildings in a semantically tagged form, for example to feed downstream fault-detection or agent workflows. It is an ingest layer only, not a control or analytics platform.
Requirements
Runs locally as a Python package (Python 3.11 or later) over stdio, or streamable HTTP if configured. Needs a YAML config file with the local device instance, broadcast address and polling interval, plus network access to the BACnet/IP broadcast domain. No authentication or environment variables are declared.
Before you install
The server is explicitly unauthenticated and intended for a trusted local network, so do not expose it beyond that. It broadcasts discovery traffic and polls device values on your network. Tagging quality depends on local YAML rules; a coverage report is recommended before relying on results. Read-only in this version, with no write path.

Installation

In SourceWeft

  1. Open Brick Bacnet Mcp in the dashboard and add it to a workspace.
  2. Enable the server for the chats that should use its tools.

Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.

Other MCP clients

Follow the launch instructions in the repository.

README

brick-bacnet-mcp

A read-only BACnet/IP gateway that exposes building automation point databases to LLM agents via MCP, with Brick + Project Haystack semantic tagging at ingest time.

Why this exists

The research note this implementation came out of is at https://habchy.dev/research/bacnet-msi-semantic-gap. A version of the same article is also published at AutomatedBuildings.com (link will be added when the AB.com edition goes live).

Short version: vendor agentic platforms (JCI OpenBlue, Honeywell Forge, Siemens Building X, Tridium Niagara 5) keep their semantic AI layer inside their own controls portfolios. Independent MSIs running mixed-vendor 5-50 building portfolios have BACnet point databases but no clean way to expose them in semantic-tagged form to external LLM agents. This gateway is one answer to that gap.

ezhuk/bacnet-mcp does read and write at the BACnet protocol layer with no semantic normalization. This project sits beside it: it adds the Brick + Haystack tagging step at ingest and restricts the v0.1 surface to read-only for a tighter compliance footprint.

What it does (v0.1)

  • Discovers BACnet/IP devices on the local broadcast domain (Who-Is, I-Am)
  • Enumerates objects per device (AI, AO, AV, BI, BO, BV, MSI, MSO, MSV, Schedule, Calendar)
  • Reads present-value, units, and description per object
  • Tags each object with a Brick class and a Haystack tag set using rule-based mapping (rules are extensible via YAML)
  • Exposes the tagged topology to any MCP host via four tools: list_devices, list_objects, get_object_value, get_tagged_topology

What it isn't (v0.1)

  • Not a write path. WriteProperty is intentionally out of v0.1 for the compliance-surface reasons noted in the research article.
  • Not a Niagara station integration. Fox protocol / Niagara module wrapping is a separate design.
  • Not an FDD or analytics platform. The tagged topology is meant to be consumed by downstream FDD or LLM-agent workflows. This gateway is the ingest layer only.
  • Not a UI. Output is MCP only. Pair it with Claude Desktop, Cursor, or any other MCP host.
  • Not BACnet/SC. v0.1 is BACnet/IP only. Secure Connect is a v0.2 consideration.
  • Not 223P full schema parity. v0.1 uses the simplified Brick + Haystack mapping. Full 223P entity model is a v0.2 candidate.
  • Not multi-site federated. v0.1 handles one broadcast domain at a time.
  • Not authenticated. v0.1 runs in a trusted local network environment.

Install

bash
pip install brick-bacnet-mcp

Or from source:

bash
git clone https://github.com/Yveshby27/brick-bacnet-mcpcd brick-bacnet-mcppip install -e .

Python 3.11 or later required.

Quick start

Create a config file config.yaml:

yaml
bacnet:  local_device_instance: 555001  broadcast_address: 192.168.1.255  polling_interval_seconds: 30rules:  brick: src/brick_bacnet_mcp/rules/brick_rules.yaml  haystack: src/brick_bacnet_mcp/rules/haystack_rules.yamlmcp:  transport: stdio  # or "http" for a hosted MCP host  http_port: 8080   # only if transport == httplog_level: INFO

Run the MCP server:

bash
brick-bacnet-mcp --config config.yaml

Or wire it into Claude Desktop:

json
{  "mcpServers": {    "brick-bacnet": {      "command": "brick-bacnet-mcp",      "args": ["--config", "/path/to/config.yaml"]    }  }}

Example interaction

With the server running and the simulator active (or a real BACnet/IP network reachable), an MCP-capable LLM can run:

User: List all the air-handling units across the building.

Agent (via MCP tool): calls get_tagged_topology(filter="brick:AHU")

Agent response: Found 3 AHUs. AHU-1 has 5 child points (discharge_air_temp, return_air_temp, supply_fan_status, mixed_air_damper_position, outside_air_temp). AHU-2 ... AHU-3 ...

See examples/ for full runnable scripts.

Checking coverage on your building

The starter rule library targets common US-style object-name conventions (OAT, DAT, ZNT, CHWS, AHU-1, etc.). Real-world mixed-vendor portfolios use wildly different naming. Before assuming the tool is broken or working, run:

bash
brick-bacnet-mcp --coverage-report --config config.yaml

This does one discover + enumerate + tag cycle against your network and prints:

  • Total objects discovered
  • Brick / Haystack match percentages
  • Top 20 most-common object names that no rule matched (use --top-unmatched N for a different count)
  • Top 10 hottest rules

Use the unmatched list to extend the YAML rule files for your naming convention. A first-run match rate of 30-50% is normal for a portfolio that hasn't been calibrated yet; 70%+ is what you'd want before relying on the tagged topology for LLM queries.

How tagging works

The tagger applies YAML-defined rules to map BACnet object names and units to Brick classes and Haystack tag sets. The default rule set covers about 50 common HVAC, lighting, and metering object-name patterns. Users override or extend by editing src/brick_bacnet_mcp/rules/brick_rules.yaml and haystack_rules.yaml locally.

Example rule (Brick):

yaml
- pattern: '(?i)^(oat|outside_air_temp|outsideair)$'  units: ['degF', 'degC', '°F', '°C']  brick_class: 'Outside_Air_Temperature_Sensor'

See docs/RULES.md for the rule grammar and override conventions.

Architecture

See docs/ARCHITECTURE.md. Short version:

  • discovery.py runs Who-Is broadcast, captures I-Am responses, caches device metadata
  • reader.py enumerates the object list per device and polls present-value at the configured interval
  • tagger.py applies Brick + Haystack rules to each enumerated object
  • topology.py assembles the tagged objects into a queryable graph
  • server.py exposes four MCP tools over stdio or streamable HTTP

Roadmap

v0.1 is a research instrument. The roadmap below is what the research article flagged as worth doing next IF v0.1 gets enough sustained-use signal to justify extending. None of it is committed pre-signal.

  • v0.2: COV subscription support, BACnet/SC, 223P full schema parity, SkySpark / FIN Haystack-store passthrough
  • v0.3+: Optional write path behind explicit opt-in, multi-site federation, authentication layer for non-local deployment

Acknowledgments

  • ezhuk/bacnet-mcp for the prior-art MCP + BACnet integration that this project builds beside
  • bacpypes3 for the BACnet protocol library
  • Project Haystack for the Haystack tagging vocabulary and community
  • Brick consortium for the Brick schema
  • The named MSI voices whose published positioning this research builds on: Brian Turner (Adaptive Buildings), Marc Petock (Lynxspring), Tom Shircliff and Rob Murchison (Intelligent Buildings LLC), Jim Meacham (Altura Associates), Therese Sullivan (BuildingContext), Alper Üzmezler (BASSG)

License

MIT. See LICENSE.

Contributing

See CONTRIBUTING.md. PRs welcome for rule library extensions, documentation, examples, and test coverage. Larger changes (write path, non-BACnet protocol support, UI, FDD logic) are out of v0.1 scope. Open an issue first to discuss before submitting a PR.

Source: README.md at commit 9a14a47

Tools

0
SourceWeft has not started this package in its sandbox yet, so its tools are not known.

Version history

1
  1. v0.1.0a2LatestSep 16, 2026

Score

50% of the applicable checks met

How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.

  • Reached in the last 30 days25 pts

    Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.

  • Auth declared10 pts

    Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.

  • Tools listed15 pts

    Answer tools/list without a credential, or ship a package that starts in a sandbox without one.

  • DescriptionRequired15 pts
  • Logo10 pts
  • Documentation15 pts
  • License10 pts

Other Brick integrations