
Ignition MCP
io.github.jsgoranaPublished by GitHub account jsgoranav0.1.3Updated Oct 25, 2026
MCP server for Inductive Automation Ignition: tags, alarms, history, and Perspective
Overview
MCP server for Inductive Automation Ignition gateways, letting an assistant browse and write tags, query history and alarms, manage projects, and deploy and run
- What you can do
- Diagnose the gateway and inspect its info, trial status, modules, logs, backups and performance, plus list configuration resources and run named or ad-hoc database queries through the gateway. Browse, read, write, create, export and import tags, and query tag history and its providers. Check alarm status and journal, and acknowledge alarms. List, get, create, delete, export, import and scan projects. Bootstrap projects and list, get, create, update, delete, validate and page-configure Perspective views, styles and sessions. Install and check the bridge WebDev project that enables live tag, alarm, history and Perspective tools.
- When to use it
- Useful when an assistant needs to work against an Ignition 8.3 gateway: inspecting tags, alarms and history, managing projects, or authoring and deploying Perspective views from a template. Read-only use is the default; write-enabled use is for operators who want the assistant to make changes on a gateway.
- Requirements
- Runs locally as a Python package (pipx, uvx or pip). Needs IGNITION_URL (gateway base URL) and IGNITION_API_TOKEN (API key in name:secret form) with gateway read/write permission granted. Live tag, alarm, history and Perspective tools need the mcp-bridge WebDev project installed on the gateway and IGNITION_BRIDGE_SECRET set. Optional settings cover TLS verification, timeout and a tag-write allowlist.
Installation
In SourceWeft
- Open Ignition MCP in the dashboard and add it to a workspace.
- Enable the server for the chats that should use its tools.
Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.
Other MCP clients
Follow the launch instructions in the repository.
README
ignition-mcp
An MCP (Model Context Protocol) server for Inductive Automation Ignition. It gives an AI assistant, Claude Desktop, Claude Code, or any MCP client, structured access to an Ignition gateway: browse and write tags, query history and alarms, manage projects, and deploy full Perspective views.
Tested against Ignition 8.3. 43 tools spanning tags, history, alarms, projects, gateway administration, and Perspective. The server is read-only by default; every write is gated behind an explicit opt-in.
Why two planes
Ignition 8.3 ships a native REST API, but it doesn't expose live tag values, tag history, alarm
queries, or Perspective view resources. ignition-mcp covers the gap with two transport planes:
- REST plane. The gateway's native
/data/api/v1API, authenticated with an API key, used for projects, gateway configuration, modules, logs, backups, and Perspective session diagnostics. - Bridge plane. A small WebDev project (
mcp-bridge) you install once on the gateway. It exposes the gateway scripting surface (system.tag.*,system.alarm.*,system.db.*, and project file I/O) over HMAC-signed HTTP requests.
Tools that need the bridge degrade with a clear message if it isn't installed. Run
ignition_diagnose any time to see what's configured and what's missing.
Quickstart
1. Create an API key on the gateway
Gateway web UI -> Config -> Security -> API Keys -> Create. Give it a name, for example claude.
Copy the full token; it looks like claude:AbCd....
The key's auto-created security level (Authenticated/<key-name>) needs to be granted gateway
read/write access under Config -> Security -> General -> Gateway Read/Write Permissions. Skip
this step and calls return HTTP 403; ignition_diagnose will tell you and give the exact fix.
2. Install ignition-mcp
3. Configure your MCP client
Claude Desktop (claude_desktop_config.json) or Claude Code (.mcp.json):
Restart the client and ask it to run ignition_diagnose. You should get an all-green checklist,
aside from a warning about the bridge, which is the next step.
4. Install the bridge (recommended, needed for live data and Perspective deploys)
Generate a random secret, enable writes, and let the server install the bridge for you:
Ask your assistant to install the bridge (this runs the bridge_install tool), then run
ignition_diagnose again to confirm the bridge check is green. See
docs/bridge.md for the manual install path and troubleshooting.
Configuration
Safety model
- Read-only by default. Mutating tools refuse to run unless
IGNITION_ALLOW_WRITES=trueand the call passesconfirm=true. Your assistant setsconfirmafter you approve the action. - Destructive operations echo the name back. Deleting a project or view requires re-sending its exact name.
- A tag-write allowlist lets you restrict writable tags to specific path globs.
- REST mutations carry the API key's identity into Ignition's own audit log; bridge mutations log
to the
mcp-bridgelogger. Secrets are never logged or echoed back. - The bridge's file endpoints are confined to
data/projects/; nothing outside that tree is reachable.
Tool catalog
The server also exposes MCP resources the assistant can read to author valid Perspective views:
ignition://docs/view-schema and ignition://templates/view/{flex-basic,coordinate-basic,tag-bound-dashboard}.
Building Perspective views
See docs/perspective-authoring.md for the full writeup. In
short: the assistant reads the view-schema resource, starts from a template, validates offline
with perspective_validate_view, then deploys with perspective_upsert_view, which validates
again, writes the view, and triggers a project scan. A full round-trip example is in
examples/deploy-dashboard.md.
Development
Acknowledgments
Built on the Model Context Protocol and its Python SDK, using httpx for HTTP. The ignition-sdk-examples repository was a useful reference while working out how Ignition's module and scripting APIs fit together.
License
MIT. See LICENSE.
Disclaimer
This project is independent and community-built. It is not affiliated with, endorsed by, or sponsored by Inductive Automation. "Ignition" and "Perspective" are trademarks of Inductive Automation, LLC, used here only to describe compatibility. Test any write-enabled tool against a non-production gateway before pointing it at something that matters.
Source: README.md at commit fb55db3
Tools
0Version history
1- v0.1.3LatestSep 16, 2026
Score
50% of the applicable checks met
How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.
- Reached in the last 30 days25 pts
Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.
- Auth declared10 pts
Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.
- Tools listed15 pts
Answer tools/list without a credential, or ship a package that starts in a sandbox without one.
- DescriptionRequired15 pts
- Logo10 pts
- Documentation15 pts
- License10 pts