plctap
io.github.ymxc152Published by GitHub account ymxc152v0.6.2Updated Oct 24, 2026
Agent-PLC MCP Server: read & diagnose Modbus / FINS / MELSEC / S7 / IEC 104 / ENIP / OPC UA PLCs.
Overview
Local MCP server that lets an assistant connect to, read, diagnose and optionally write industrial PLCs over Modbus, FINS, MELSEC, S7, IEC 104, EtherNet/IP and,
- What you can do
- Detect and probe devices: identify the protocol on a host, check connectivity and attribute failures by layer, browse OPC UA address spaces and list supported protocols and their addressing models. Read PLC data areas across eight protocol endpoints and interpret values by datatype and byte order. Diagnose: parse and validate single frames, run a rule-based diagnosis over logs, and parse Wireshark pcap exports. Capture traffic: run a fake server listener with optional error injection, or a transparent proxy that records both directions. Write and send frames: register writes and raw frame sends only when the write gate is enabled, with per-frame audit logging.
- When to use it
- Useful for field diagnostics and commissioning of industrial equipment: figuring out what protocol a device speaks, confirming reachability, comparing read values with an HMI, and turning captured frames or logs into structured conclusions. Also suited to regression-testing HMI fault tolerance through the listener's error injection.
- Requirements
- Runs locally as a stdio process, installed with uvx or pipx (Python). Network access to the PLC or gateway hosts and their ports is required. Optional environment variables: PLCTAP_ALLOW_WRITE (default false), PLCTAP_DEFAULT_TIMEOUT_MS, PLCTAP_POOL_MAX_PER_TARGET, PLCTAP_IDLE_TIMEOUT_SEC, PLCTAP_AUDIT_LOG. pcap parsing needs the eval extra installed.
Installation
In SourceWeft
- Open plctap in the dashboard and add it to a workspace.
- Enable the server for the chats that should use its tools.
Desktop only via STDIO. STDIO servers start a local process, so they need the SourceWeft desktop host.
Other MCP clients
Follow the launch instructions in the repository.
README
plctap
中文 | English
Agent 的 PLC 驱动层 — 让 Claude / Codex / Cursor 直接连接、读写、诊断 Modbus TCP / Modbus RTU over TCP / FINS / MELSEC / Siemens S7comm / IEC 60870-5-104 / EtherNet/IP (CIP) 设备的 MCP Server。
[CI] [PyPI] [MCP Registry] [License: MIT]
状态: v0.6 (协议自动识别 + 透明代理 + 故障注入监听 + 八协议端点接入 (含 OPC UA 连接级诊断), 六端点可写 (IEC 104 / OPC UA 仅读); IEC 104 经 lib60870、EtherNet/IP 经 pycomm3 官方实现交叉验证, OPC UA 为 asyncua 官方库台架自洽验证)。
工具
全部工具带 MCP annotations hint (wire 逐键锁定于 tests/test_tool_annotations.py): 纯本地解析类
readOnlyHint=true / openWorldHint=false, 联网读/探测/取帧类 readOnlyHint=true, 监听/代理
启停为非只读状态变更 (非破坏、非幂等), 写类 destructiveHint=true 且默认不注册 —— 客户端可
据此判断并行安全性与调用前确认级别。
写能力
PLCTAP_ALLOW_WRITE=true 后八端点中六个可写 (modbus_rtu 与 modbus 同轨同语义; iec104 与 opcua 仅读):
所有写/发送动作逐帧写入审计日志 (发送前留痕, 失败也留)。
协议速查
八个端点的寻址模型与常用参数 (接入前先对表; 工具内 list_protocols 亦可动态获取):
datatype 支持 uint16 / int16 / float32 / int32; byteorder 仅影响 float32 的寄存器对顺序
(big=ABCD, little=DCBA)。datatype 缺省时返回全部常见类型 × 字序的多解释, 字序存疑时直接比对。
示例调用 (客户端中按参数填写):
modbus 与 modbus_rtu 怎么选: 网关/上位机已封装 MBAP 头 (标准 Modbus TCP) → modbus;
串口服务器或网关工作在 RTU 透传模式 (TCP 上是裸 RTU 帧) → modbus_rtu。
典型工作流 (现场诊断)
detect_device(host=...)— 不知道对面是什么: 并发探测标准端口, 按响应指纹判定协议/端口/置信度, 返回可直接执行的plc_read建议 (全程只读)。probe_device(protocol, host, port)— 连通性确认; 失败时四类分层归因 (connection_refused / timeout / connected_but_no_reply / exception_response), 直接告诉您该查网络路由还是查协议配置 (IEC 104 为 STARTDT+TESTFR 握手探测)。plc_read(...)— 按「协议速查」读数, 与上位机显示或预期值比对。- 读数不对 / 通信故障 → 抓包帧喂
parse_frame/validate_frame做结构化解析与规范校验; 日志文本喂diagnose得到带证据链的结构化候选结论。 - 要看上位机 ↔ PLC 全部交互 →
start_proxy透明代理 (上位机改指向代理即可, 免 Wireshark); 设备只能当 client 主动外连 →start_listener假 server 钓帧, 支持inject_errors故障注入档做上位机容错回归。
快速开始
已收录于 MCP 官方 Registry: io.github.ymxc152/plctap
(支持按名称检索与安装的客户端可直接发现本服务)。
Claude Desktop 接入 (claude_desktop_config.json)
本地开发 (仓库检出路径):
Codex 接入 (~/.codex/config.toml)
配置 (环境变量, 均有默认值)
安全
- 写操作默认完全不注册; 显式
PLCTAP_ALLOW_WRITE=true才启用。 - 所有写/发送动作逐条写入 JSONL 审计日志 (
~/.plctap/audit.jsonl, 不可关)。 - 发送类调用请配合客户端审批弹窗使用 (用户可见目标 IP 与完整帧)。
- 审计日志样例:
{"ts":"2026-09-04T01:20:33+0800","tool":"plc_write","target":"modbus://127.0.0.1:15020 unit=1","frame_hex":"0002000000060106000104d2","caller":"mcp"}
开发
质量保障
- 569 项测试(codec 纯函数 + 适配器(含 Modbus RTU / IEC 104 / EtherNet/IP / OPC UA)+ 诊断引擎 + 监听器 + 透明代理 + detect_device + MCP 冒烟),CI 每次推送回归。
- 跨厂商 e2e(tests/e2e):plctap 与 pymodbus、python-snap7、
pymcprotocol、pypi fins、MZ Automation 官方 lib60870.NET、pycomm3(Rockwell 官方客户端库)六个第三方权威实现做真实 socket 交叉验证
(读写闭环、读数逐值比对、钓鱼监听互通),CI 随行(
uv sync --group e2e); IEC 104 交叉验证需 .NET 8 SDK(缺省自动跳过)。OPC UA 端点为 asyncua 官方库 + 台架自洽验证(会话协议无帧级诊断,与本节其余端点的字节级交叉验证口径不同,如实区分)。 - 八档评测 49/49:单帧 / RTU 完整性 / 批量日志 / FINS·MELSEC 专项 / 主动探测归因 / 协议自动识别 / IEC 104 专项 / EtherNet/IP 专项 (detect 档含"回显服务器欺骗"与"证据压过端口先验"两类反例);与裸模型的双跑对比见下节。
评测对比 (裸模型基线双跑: 五档 35 用例)
* 同一批语料双跑, 除工具外一切相同: 裸模型 (glm-5.3-flash, 无工具, temperature=0) 直接问答; 确定性关键词判分 (事实等价集, 双模式共用); 6 例因推理端点超时未获有效答案计 FAIL (排除超时后 24/29 = 82.8%)。裸模型跑分日期 2026-09-04, 语料版本 317e868 (跑分时点; fins 语料其后于 b319374 随线上格式修正同步更新, 判分语义不变)。 范围说明: 语料建于 M2 (v0.2 时代), 覆盖帧解析 / CRC 完整性 / 日志混排 / 冷门协议语义 / 主动探测归因; v0.3+ 功能 (plc_write / parse_pcap / 透明代理 / modbus_rtu 端点 / vendor_hints / iec104 端点 / enip 端点 / opcua 端点) 未纳入基线。detect 档 (4 用例, v0.4 新增)、iec104 档 (6 用例, v0.5.2 新增) 与 enip 档 (4 用例, v0.5.3 新增) 需起真实网络服务/台架做主动探测与交互, 不适合裸问答 形式, 故未纳入对比 —— 工具模式八档合计 49/49 (2026-09-07 按当前语料复跑, 见「质量保障」)。 结论: 单帧翻译裸模型已能胜任, 价值差距集中在冷门协议语义与多故障混排场景 —— 这正是确定性解析 + 结构化知识库的所在。方法学与复跑步骤见 eval/README.md。
运行时边界: eval/ 是开发期基准测试 harness (裸模型基线对比), 仅复跑评测时需要
PLCTAP_ 前缀环境变量 (key/端点/模型全部显式提供, 仓库不内置任何厂商端点);
发布产物只含 src/plctap —— MCP server 运行时零 AI/LLM 依赖,
不读也不需要任何模型 API 凭据。
多模型裸基线矩阵 (2026-09-08: 4 模型 × 双跑 × 五档 35 用例)
换任何裸模型 (弱/中/强/Agent 同款) 都在 8~13/35 徘徊, 冷门协议档 8 轮合计 0/96; 挂上 plctap 工具层后 49/49 (八档), 且与模型强弱无关。 两种失败模式同时被工具层免疫: 推理跑飞 (八轮 81 次零输出, 单例实测烧满 32768 reasoning tokens 无正文) 与 "流畅的错误" (deepseek-v4-flash 无答案仅 2/2 却总分最低, FINS/MELSEC 档 12 条全错)。
* 无答案 = 模型零输出 (推理超时), 计 FAIL (09-04 口径沿用)。本矩阵与上表 (2026-09-04, 24/35) 不可同表硬比: 端点不同 (火山方舟 vs Codex 本地代理)、服务端模型版本可能漂移、 判分等价集为当期校准 —— 同名模型 ≠ 同条件。双跑总分逐分复现 (temperature=0), 分档内部 有小幅漂移。完整矩阵与方法学见 eval/README.md。
版本与兼容承诺
自 v0.6.1 起遵循稳定化纪律:
- 向后兼容: MCP 工具名、参数名与各工具的返回结构保持兼容。返回结构由 pydantic 模型
定义并锁定 (
tests/test_tool_shapes.py黄金校验; 例外: list_protocols 的 protocols 条目为自由形态 dict); 新增协议端点、新增工具、新增可选参数只增不改。 - 工具 annotations: 17 个工具的 readOnlyHint/destructiveHint/idempotentHint/openWorldHint
四项全显式 (server.py
_ANN_*四分组), 黄金值锁定于tests/test_tool_annotations.py; annotations 属只增元数据, 任何取值变化按 wire 变化对待。 - 破坏性变更: 若不可避免, 在工具 docstring、本 README 与 Release notes 三处提前标注, 并尽量提供迁移期。
- 不承诺面:
src/plctap内部模块组织、诊断知识库条目数、评测数字随版本正常演进。 - 1.0 (语义定稿) 的宣布条件: 上述纪律经过至少一个完整发布周期的验证, 届时另行公告。
License
MIT
Source: README.md at commit 615b04d
Tools
0Version history
1- v0.6.2LatestSep 16, 2026
Score
50% of the applicable checks met
How complete this listing is, computed from the registry entry, the endpoint and public sources. Not a rating of the server and not a statement that it is safe or working today: reachability is a dated check, and no installs or reviews go into the score.
- Reached in the last 30 days25 pts
Keep the endpoint answering the MCP handshake; SourceWeft probes it every 30 days.
- Auth declared10 pts
Declare the credential headers in the registry entry, or keep the endpoint answering the probe so its auth can be classified.
- Tools listed15 pts
Answer tools/list without a credential, or ship a package that starts in a sandbox without one.
- DescriptionRequired15 pts
- Logo10 pts
- Documentation15 pts
- License10 pts