wire_size
Wire size calculator
Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.
输入参数amps必填feet必填temp必填limit必填phase必填volts必填material必填
voltage_drop
Voltage drop calculator
Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).
输入参数awg必填amps必填feet必填phase必填volts必填material必填
watts_to_amps
Watts to amps calculator
Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.
输入参数pf必填phase必填volts必填watts必填
conduit_fill
Conduit fill calculator
Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.
输入参数awg必填size必填type必填count必填
box_fill
Box fill calculator
Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.
输入参数awg必填clamps必填devices必填grounds必填conductors必填
load_calculator
Residential load calculator (NEC 220.82)
Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.
输入参数evhvacsqft必填dryerotherrangesmall必填heaterlaundry必填disposaldishwasher
ohms_law
Ohm's law calculator
Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.
输入参数iprv
panel_schedule
Panel schedule generator
Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.
输入参数spaces必填system必填circuits必填
bid_calculator
Electrical bid calculator
Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).
输入参数rate必填hours必填directmargin必填markupoverhead必填materials必填
nec_ampacity
NEC Table 310.16 ampacity lookup
Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.
输入参数size必填temp必填material必填