OpenMEP duct sizing
io.github.samarmstrong由 GitHub 账号 samarmstrong 发布v0.2.0更新于 Oct 24, 2026
Deterministic HVAC duct sizing at a fixed or Manual D friction rate; grades existing ducts.
概览
一个本地 MCP 服务器,让助手按固定摩擦率或 Manual D 摩擦率确定性地进行暖通空调风管选型,并评估现有风管。
- 可以做什么
- 根据风量、用途、气流类型以及可选的现有圆形、矩形或椭圆形截面,为单段风管选型,返回推荐的标准圆管直径、风速、摩擦率,以及现有风管的合格、偏小或偏大评级。为整张风管网络(由终端、管段、管件和设备通过引用连接)选型,返回每段的 CFM、用途、建议和评级。在给定风机静压和长度时,推导 Manual D 设计:可用静压、总有效长度、摩擦率和控制路径。报告缺失风量、终端未连接、悬空引用、混合系统、偏小或偏大管段以及摩擦率超出 0.06–0.18 等问题。
- 适用场景
- 当助手需要进行初步的暖通空调风管选型,或判断现有风管是否偏小、偏大或合适时适用,包括带风机静压的整网布局。结果仅作为供工程师复核的初步选型。
- 运行要求
- 通过 npx 从 npm 包 @openmep/mcp 以 stdio 在本地运行,需要 Node.js 24+。无需编辑器、CAD 宿主、账户、API 密钥或网络访问。
安装
在 SourceWeft 中
- 打开 控制台中的 OpenMEP duct sizing,将其添加到工作区。
- 为需要使用其工具的对话启用该服务。
Desktop only,通过 STDIO。 STDIO 服务会启动本地进程,因此需要 SourceWeft 桌面宿主。
其他 MCP 客户端
参照 仓库 中的启动说明。
README
@openmep/mcp
An MCP server that gives any agent OpenMEP's deterministic HVAC duct sizing. No editor, CAD host, account, or network access: the agent describes the ducts, the engine sizes them.
Claude Code: claude mcp add openmep -- npx -y -p @openmep/mcp openmep-mcp.
Requires Node.js 24+. Transport: stdio.
Tools
Both tools are read-only and idempotent. Invalid input comes back as a tool
error naming the field (NetworkInputError [invalid-item]: items[2].requiredCfm: ...)
so the model can correct it.
Example prompt that works in a fresh Claude Code session with only this server:
I have a furnace feeding a supply trunk that tees into two runouts: bedroom 1 needs 120 CFM, bedroom 2 needs 90 CFM, and the living room is fed off the trunk end at 200 CFM. All drawn as 6 inch round. One return grille in the hall at 410 CFM on a 10 inch drop. Is anything undersized?
The agent builds the network in one size_duct_network call and reports 7, 6,
and 8 in runouts, an 11 in trunk, and a return drop just under size at 10 in.
Engineering basis and limits
Equal friction at 0.08 in. w.g./100 ft, or at the Manual D rate derived from the blower's
available static pressure when fan and lengths are given, with role-based velocity caps per system,
rounded up to standard round diameters; see
@openmep/hvac-domain for the formula,
sources, and what is excluded (fitting losses, static pressure summation, fan
selection). Airflow is a design input the server never estimates. Treat results
as preliminary sizing for an engineer to review.
The server uses the official MCP TypeScript SDK and speaks the
initialize-handshake protocol revisions (through 2025-11-25), which current
clients support.
Library
来源:packages/mcp/README.md,提交 4f57471
工具
0版本历史
2- v0.2.0最新Oct 7, 2026
- v0.1.0Sep 23, 2026
评分
已满足适用检查项的 50%
该评分衡量此收录条目的完整程度,依据注册中心条目、端点与公开来源计算得出。它不是对服务器本身的评价,也不表示服务器安全或当前可用:可连通性是带日期的检查结果,评分也不包含安装量或用户评价。
- 近 30 天内可连通25 分
请保持端点能够响应 MCP 握手;SourceWeft 每 30 天探测一次。
- 已声明认证方式10 分
请在注册中心条目中声明凭据请求头,或保持端点能够响应探测,以便判定其认证方式。
- 已列出工具15 分
请让服务器在无凭据时响应 tools/list,或发布可在沙箱中无凭据启动的软件包。
- 描述必需15 分
- 图标10 分
- 文档15 分
- 许可证10 分