S1000D Writer (S1000D Stack)
io.github.shuji-bonji由 GitHub 帳號 shuji-bonji 發布v0.2.0更新於 Nov 7, 2026
Builds S1000D data modules from structured drafts, verifies them, applies only unambiguous fixes.
概覽
S1000D Writer (S1000D Stack) 的本機 MCP 服務;無需登入;STDIO。
暫無 AI 概覽:以下資訊來自註冊中心條目和服務本身。
安裝
在 SourceWeft 中
- 開啟 儀表板中的 S1000D Writer (S1000D Stack),將其新增到工作區。
- 為需要使用其工具的對話啟用該服務。
Desktop only,透過 STDIO。 STDIO 服務會啟動本機處理程序,因此需要 SourceWeft 桌面主機。
其他 MCP 客戶端
參照 儲存庫 中的啟動說明。
README
@shuji-bonji/s1000d-writer-mcp
English | 日本語
An MCP server that lets an LLM create S1000D® data modules without writing XML. The LLM passes a structured draft and numbering rules; the server builds the XML, verifies it against the XSD, the BREX and the references, and applies automatically only the fixes that have exactly one candidate (exact). A fix with several candidates is applied only from a selection, and a value outside the candidates is never accepted. By default nothing is written.
[!IMPORTANT] This is a personal project and is not affiliated with ASD (Aerospace, Security and Defence Industries Association of Europe). S1000D® is a registered trademark of ASD. The S1000D specification, XML schemas, default BREX and official samples are not included in any package or repository, because their terms of use do not grant redistribution. Obtain them from s1000d.org and point the
S1000D_SPEC_DIRenvironment variable at the extracted folder.
What it does
Write rules
- Nothing is written by default. Only with
write: truedoes the server writeDMC-….XMLinto the first folder ofcsdbDirs(or the first ofS1000D_CSDB_DIR). With no destination it writes nothing and returns the reason (no-csdb-dir). - A file with the same name is not overwritten (
write-conflict) unlessoverwrite: trueis passed. - XML that violates the XSD is not written (
schema-invalid) unlessallowInvalid: trueis passed.schema-not-found(no XSD available) is not a violation; the file is written as unverified. - With
write: true,convert_manualalso copies the original assets under their ICN file names.
What is fixed automatically
Only a fix whose confidence is exact and which has exactly one candidate is applied (for example, replacing a value when the BREX allows a single responsible company, or removing an element the BREX forbids). several (more than one candidate, or a value given as a range) and none are not applied and are returned in fixes[]. The user chooses, and the server never fixes with a value outside the candidates. Each applied fix is returned in appliedFixes[] with the values before and after.
Verification status (verification)
Every response carries the verification status of the XSD, the BREX and the references. A missing XSD is reported as schema-not-found and a skipped step as not-run; neither is valid. The server reports the result of verification only: it does not judge conformance to S1000D and does not interpret severity.
Input errors
A mistake in the draft or the numbering rules is returned not as isError but as error: { code: "input-error", path, detail }. path is the location of the mistake (for example /body[1] or /allocation/rules/infoCodeByKind/proced). Fix it and call again.
What it does not do
[!WARNING]
- It does not accept XML written by an LLM. It builds only from a draft. The tools that take existing XML (
apply_fixes,extract_segments,apply_segments) do not change the structure of the document.- It does not fix with a value outside the candidates. There is no entry point for writing a free value.
- It does not skip verification. A built XML is always verified before it is returned.
- It does not judge conformance to S1000D or interpret severity. Read the violations in
s1000d-verify-mcpand the explanation of BREX rules ins1000d-brex-mcp.- It does not translate. It only takes sentences out and puts them back. The LLM or a person translates.
- It does not create illustrations or judge Simplified Technical English (STE). For an illustration it only allocates an ICN and inserts the reference.
- What a data module cannot represent, such as hotspot coordinates or part of
scopeRefsin an experiential manual, is reported innotRepresentedand never dropped silently.- It does not create an ACT, CCT or PCT. Applicability relies on the
applicof the draft and an existing applicability repository. When a draft given tobuild_data_modulehas noapplic, the server does not build it and returnsinput-error(pathis/applic). The server does not decide applicability, so give at leastapplic.displayText(convert_manualusesdefaultApplic, by default the display text "All", for topics withoutscopeRefs).
Configuration
You can also give folders with the tool argument csdbDirs (the first one is the write destination). When the argument is given, only those folders are used; S1000D_CSDB_DIR and csdbDirs in the config file are not used (they are not added together). Folders that do not exist are skipped and listed in _notes of the response. The first folder may not exist yet; it is created with write: true.
Config file (when environment variables are not passed, such as a Claude Desktop plugin)
When S1000D_SPEC_DIR / S1000D_CSDB_DIR are not set, the server reads the config file ~/.config/s1000d-stack/config.json (under XDG_CONFIG_HOME if set; the location can be changed with S1000D_CONFIG). Claude Desktop does not pass environment variables to a server installed as a plugin, so write the settings here in that case.
Environment variables take precedence when they are set. The config file is read again on every call.
Example configuration for Claude Desktop / Claude Code
Running over HTTP (embedding in a product)
The default is stdio. With --http the server starts over Streamable HTTP.
When --host is a loopback address, Host and Origin are limited to localhost names (DNS rebinding protection). When bound to any other address they are not checked, so put the server behind the product's reverse proxy or authentication. Because this server can write files, do not expose it without authentication.
How it works
All building, verification, fixing, comment and segment code lives in the shared library @shuji-bonji/s1000d-core; this server holds only the interpretation of arguments, the shape of the responses and the conversion from a manual to drafts (src/convert/). The input schemas import the definitions of core's draft.schema.json. The conversion is also available as @shuji-bonji/s1000d-writer-mcp/convert.
Development
License
MIT. S1000D® is a registered trademark of ASD. This software is not affiliated with ASD and does not include the specification, schemas or official samples.
來源:README.md,提交 6660946
工具
0版本歷史
2- v0.2.0最新Nov 7, 2026
- v0.1.2Oct 29, 2026
評分
已滿足適用檢查項的 50%
該評分衡量此收錄條目的完整程度,依據註冊中心條目、端點與公開來源計算得出。它不是對伺服器本身的評價,也不表示伺服器安全或目前可用:可連通性是帶日期的檢查結果,評分也不包含安裝量或使用者評價。
- 近 30 天內可連通25 分
請保持端點能夠回應 MCP 握手;SourceWeft 每 30 天探測一次。
- 已宣告認證方式10 分
請在註冊中心條目中宣告憑證請求標頭,或保持端點能夠回應探測,以便判定其認證方式。
- 已列出工具15 分
請讓伺服器在無憑證時回應 tools/list,或發布可在沙箱中無憑證啟動的軟體包。
- 描述必需15 分
- 圖示10 分
- 文件15 分
- 授權條款10 分